STANDARD XCHANGE Plate Heat Exchanger Replacement Gasket
Plate Heat Exchanger Replacement Gasket, Product Type Replacement Gasket, Material Nitrile HT, Includes Not Applicable, Compatible with Manufacturer Model Number P4-20-TL, P4-30-TL, P4-40-TL, Compatible with Series P4, Compatible with Grainger Part Number 810RC8, 810RC9, 810RD0, Compatible with Brand Standard Xchange
STANDARD XCHANGE Heat Exchanger,2,400,000 BtuH,30 5/8in L
Heat Exchanger, Heat Dissipation Capacity for Water 2,400,000 BtuH, Heat Dissipation Capacity for Oil 280,000 BtuH, Total Surface Area 41 sq ft, Shell Outside Diameter 8 1/8 in, Tube Length 30 5/8 in, Shell Material Stainless Steel, Tube Material Stainless Steel, Number of Passes 4, Shell Maximum Pressure Rating 225 psig, Shell Maximum Operating Temperature 450 Degrees F, Tube Maximum Pressure Rating 150 psig, Tube Maximum Operating Temperature 450 Degrees F
STANDARD XCHANGE Shell/Tube Heat Exchanger,Copper,14"L
Heat Exchanger, Heat Dissipation Capacity for Water 525,000 BtuH, Heat Dissipation Capacity for Oil 27,000 BtuH, Total Surface Area 9.2 sq ft, Shell Outside Diameter 8 in, Tube Length 14 in, Shell Material Carbon Steel, Tube Material Copper, Number of Passes 4, Shell Maximum Pressure Rating 300 psig, Shell Maximum Operating Temperature 300 Degrees F, Tube Maximum Pressure Rating 150 psig, Tube Maximum Operating Temperature 300 Degrees F, Fluid Compatibility Fluids, Jacket Water, Lube Oil
STANDARD XCHANGE Plate Heat Exchanger Replacement Gasket
Plate Heat Exchanger Replacement Gasket, Product Type Replacement Gasket, Material Nitrile HT, Includes Not Applicable, Compatible with Manufacturer Model Number P19-100-TL, P19-20-TL, P19-30-TL, P19-40-TL, P19-60-TL, P19-80-TL, Compatible with Series P19, Compatible with Grainger Part Number 810RD8, 810RD9, 810RE0, 810RE1, 810RE2, 810RE3, Compatible with Brand Standard Xchange
STANDARD XCHANGE Heat Exchanger,50 1/2 in Overall H
Heat Exchanger, Heat Exchanger Type Braze Plate, Mounting Stud Thread Size Not Applicable, Heat Dissipation Capacity for Water 303,000 BtuH, Heat Dissipation Capacity for Oil Not Applicable, Heat Dissipation Capacity for Refrigerant Not Applicable, Total Surface Area 75.5 sq ft, Overall Height 50 1/2 in, Overall Width 50 1/2 in, Overall Depth 27 in, Maximum Pressure Rating 200 psi, Maximum Operating Temperature 350 Degrees F, Minimum Operating Temperature -10 Degrees F, Flow Capacity 85 gpm
STANDARD XCHANGE Heat Exchanger,40 1/2 in Overall H
Heat Exchanger, Heat Exchanger Type Braze Plate, Mounting Stud Thread Size Not Applicable, Heat Dissipation Capacity for Water 202,000 BtuH, Heat Dissipation Capacity for Oil Not Applicable, Heat Dissipation Capacity for Refrigerant Not Applicable, Total Surface Area 47 sq ft, Overall Height 40 1/2 in, Overall Width 40 1/2 in, Overall Depth 25 in, Maximum Pressure Rating 200 psi, Maximum Operating Temperature 350 Degrees F, Minimum Operating Temperature -10 Degrees F, Flow Capacity 68 gpm
STANDARD XCHANGE Heat Exchanger;65 1/2 in Overall H
Heat Exchanger; Heat Exchanger Type Braze Plate; Mounting Stud Thread Size Not Applicable; Heat Dissipation Capacity for Water 535;000 BtuH; Heat Dissipation Capacity for Oil Not Applicable; Heat Dissipation Capacity for Refrigerant Not Applicable; Total Surface Area 130.6 sq ft; Overall Height 65 1/2 in; Overall Width 65 1/2 in; Overall Depth 32 3/4 in; Maximum Pressure Rating 200 psi; Maximum Operating Temperature 350 Degrees F; Minimum Operating Temperature -10 Degrees F
STANDARD XCHANGE Gasketed Plate Heat Exchanger;150 psi
Gasketed Plate Heat Exchanger; Heat Exchanger Type Plate and Frame; Mounting Stud Thread Size Not Applicable; Heat Dissipation Capacity for Water 1;724;000 BtuH; Heat Dissipation Capacity for Oil 323;300 BtuH; Heat Dissipation Capacity for Refrigerant Not Applicable; Total Surface Area 29.03 sq ft; Overall Height 34 in; Overall Width 12 1/8 in; Overall Depth 27 3/8 in; Maximum Pressure Rating 150 psi; Maximum Operating Temperature 284 Degrees F; Minimum Operating Temperature 32 Degrees F
STANDARD XCHANGE Gasketed Plate Heat Exchanger;150 psi
Gasketed Plate Heat Exchanger; Heat Exchanger Type Plate and Frame; Mounting Stud Thread Size Not Applicable; Heat Dissipation Capacity for Water 443;900 BtuH; Heat Dissipation Capacity for Oil 76;500 BtuH; Heat Dissipation Capacity for Refrigerant Not Applicable; Total Surface Area 7.75 sq ft; Overall Height 19 in; Overall Width 8 1/2 in; Overall Depth 16 3/8 in; Maximum Pressure Rating 150 psi; Maximum Operating Temperature 284 Degrees F; Minimum Operating Temperature 32 Degrees F
STANDARD XCHANGE Gasketed Plate Heat Exchanger;150 psi
Gasketed Plate Heat Exchanger; Heat Exchanger Type Plate and Frame; Mounting Stud Thread Size Not Applicable; Heat Dissipation Capacity for Water 3;909;800 BtuH; Heat Dissipation Capacity for Oil 697;700 BtuH; Heat Dissipation Capacity for Refrigerant Not Applicable; Total Surface Area 61.35 sq ft; Overall Height 34 in; Overall Width 12 1/8 in; Overall Depth 27 3/8 in; Maximum Pressure Rating 150 psi; Maximum Operating Temperature 284 Degrees F; Minimum Operating Temperature 32 Degrees F
STANDARD XCHANGE Gasketed Plate Heat Exchanger;150 psi
Gasketed Plate Heat Exchanger; Heat Exchanger Type Plate and Frame; Mounting Stud Thread Size Not Applicable; Heat Dissipation Capacity for Water 61;489;600 BtuH; Heat Dissipation Capacity for Oil 7;953;000 BtuH; Heat Dissipation Capacity for Refrigerant Not Applicable; Total Surface Area 1;032.04 sq ft; Overall Height 79 in; Overall Width 25 3/4 in; Overall Depth 58 1/4 in; Maximum Pressure Rating 150 psi; Maximum Operating Temperature 284 Degrees F; Minimum Operating Temperature 32 Degrees F
STANDARD XCHANGE Heat Exchanger;65 1/2 in Overall H
Heat Exchanger; Heat Exchanger Type Braze Plate; Mounting Stud Thread Size Not Applicable; Heat Dissipation Capacity for Water Not Applicable; Heat Dissipation Capacity for Oil 433;000 BtuH; Heat Dissipation Capacity for Refrigerant Not Applicable; Total Surface Area 130.6 sq ft; Overall Height 65 1/2 in; Overall Width 65 1/2 in; Overall Depth 32 3/4 in; Maximum Pressure Rating 200 psi; Maximum Operating Temperature 350 Degrees F; Minimum Operating Temperature -10 Degrees F
STANDARD XCHANGE Heat Exchanger;18 in Overall H
Heat Exchanger; Heat Exchanger Type Braze Plate; Mounting Stud Thread Size Not Applicable; Heat Dissipation Capacity for Water Not Applicable; Heat Dissipation Capacity for Oil 22;500 BtuH; Heat Dissipation Capacity for Refrigerant Not Applicable; Total Surface Area 7.5 sq ft; Overall Height 18 in; Overall Width 18 in; Overall Depth 21 7/8 in; Maximum Pressure Rating 200 psi; Maximum Operating Temperature 350 Degrees F; Minimum Operating Temperature -10 Degrees F; Flow Capacity 60 gpm
STANDARD XCHANGE Gasketed Plate Heat Exchanger;150 psi
Gasketed Plate Heat Exchanger; Heat Exchanger Type Plate and Frame; Mounting Stud Thread Size Not Applicable; Heat Dissipation Capacity for Water 59;579;300 BtuH; Heat Dissipation Capacity for Oil 8;334;300 BtuH; Heat Dissipation Capacity for Refrigerant Not Applicable; Total Surface Area 872.85 sq ft; Overall Height 72 1/2 in; Overall Width 20 1/2 in; Overall Depth 57 3/4 in; Maximum Pressure Rating 150 psi; Maximum Operating Temperature 284 Degrees F; Minimum Operating Temperature 32 Degrees F
STANDARD XCHANGE Heat Exchanger;45 1/2 in Overall H
Heat Exchanger; Heat Exchanger Type Braze Plate; Mounting Stud Thread Size Not Applicable; Heat Dissipation Capacity for Water Not Applicable; Heat Dissipation Capacity for Oil 195;000 BtuH; Heat Dissipation Capacity for Refrigerant Not Applicable; Total Surface Area 60.4 sq ft; Overall Height 45 1/2 in; Overall Width 45 1/2 in; Overall Depth 25 in; Maximum Pressure Rating 200 psi; Maximum Operating Temperature 350 Degrees F; Minimum Operating Temperature -10 Degrees F; Flow Capacity 95 gpm
STANDARD XCHANGE Shell/Tube Heat Exchanger;Copper;36"L
Heat Exchanger; Heat Dissipation Capacity for Water 2;700;000 BtuH; Heat Dissipation Capacity for Oil 395;000 BtuH; Total Surface Area 68.3 sq ft; Shell Outside Diameter 8 in; Tube Length 36 in; Shell Material Carbon Steel; Tube Material Copper; Number of Passes 4; Shell Maximum Pressure Rating 300 psig; Shell Maximum Operating Temperature 300 Degrees F; Tube Maximum Pressure Rating 150 psig; Tube Maximum Operating Temperature 300 Degrees F; Fluid Compatibility Fluids; Jacket Water; Lube Oil
STANDARD XCHANGE Gasketed Plate Heat Exchanger;150 psi
Gasketed Plate Heat Exchanger; Heat Exchanger Type Plate and Frame; Mounting Stud Thread Size Not Applicable; Heat Dissipation Capacity for Water 1;341;600 BtuH; Heat Dissipation Capacity for Oil 214;300 BtuH; Heat Dissipation Capacity for Refrigerant Not Applicable; Total Surface Area 24.11 sq ft; Overall Height 30 in; Overall Width 8 1/2 in; Overall Depth 16 3/8 in; Maximum Pressure Rating 150 psi; Maximum Operating Temperature 284 Degrees F; Minimum Operating Temperature 32 Degrees F
STANDARD XCHANGE Heat Exchanger;2;750;000 BtuH;42 5/8in L
Heat Exchanger; Heat Dissipation Capacity for Water 2;750;000 BtuH; Heat Dissipation Capacity for Oil 400;000 BtuH; Total Surface Area 62 sq ft; Shell Outside Diameter 8 1/8 in; Tube Length 42 5/8 in; Shell Material Stainless Steel; Tube Material Stainless Steel; Number of Passes 4; Shell Maximum Pressure Rating 225 psig; Shell Maximum Operating Temperature 450 Degrees F; Tube Maximum Pressure Rating 150 psig; Tube Maximum Operating Temperature 450 Degrees F
STANDARD XCHANGE Heat Exchanger;20 1/2 in Overall H
Heat Exchanger; Heat Exchanger Type Braze Plate; Mounting Stud Thread Size Not Applicable; Heat Dissipation Capacity for Water Not Applicable; Heat Dissipation Capacity for Oil 26;800 BtuH; Heat Dissipation Capacity for Refrigerant Not Applicable; Total Surface Area 10.2 sq ft; Overall Height 20 1/2 in; Overall Width 20 1/2 in; Overall Depth 22 in; Maximum Pressure Rating 200 psi; Maximum Operating Temperature 350 Degrees F; Minimum Operating Temperature -10 Degrees F; Flow Capacity 80 gpm
STANDARD XCHANGE Plate Heat Exchanger Replacement Gasket
Plate Heat Exchanger Replacement Gasket; Product Type Replacement Gasket; Material Nitrile HT; Includes Not Applicable; Compatible with Manufacturer Model Number P-62-143-TM; P62-173-TM; Compatible with Series P62; Compatible with Grainger Part Number 810RF2; 810RF3; Compatible with Brand Standard Xchange
STANDARD XCHANGE Heat Exchanger;3;800;000 BtuH;78 5/8in L
Heat Exchanger; Heat Dissipation Capacity for Water 3;800;000 BtuH; Heat Dissipation Capacity for Oil 649;000 BtuH; Total Surface Area 124 sq ft; Shell Outside Diameter 8 1/8 in; Tube Length 78 5/8 in; Shell Material Brass; Tube Material Copper; Number of Passes 4; Shell Maximum Pressure Rating 225 psig; Shell Maximum Operating Temperature 300 Degrees F; Tube Maximum Pressure Rating 150 psig; Tube Maximum Operating Temperature 300 Degrees F; Fluid Compatibility Glycol; Oil; Steam; Water
STANDARD XCHANGE Gasketed Plate Heat Exchanger;150 psi
Gasketed Plate Heat Exchanger; Heat Exchanger Type Plate and Frame; Mounting Stud Thread Size Not Applicable; Heat Dissipation Capacity for Water 15;524;700 BtuH; Heat Dissipation Capacity for Oil 2;157;300 BtuH; Heat Dissipation Capacity for Refrigerant Not Applicable; Total Surface Area 232.07 sq ft; Overall Height 44 3/4 in; Overall Width 17 5/8 in; Overall Depth 28 3/8 in; Maximum Pressure Rating 150 psi; Maximum Operating Temperature 284 Degrees F; Minimum Operating Temperature 32 Degrees F
STANDARD XCHANGE Heat Exchanger;45 1/2 in Overall H
Heat Exchanger; Heat Exchanger Type Braze Plate; Mounting Stud Thread Size Not Applicable; Heat Dissipation Capacity for Water 252;000 BtuH; Heat Dissipation Capacity for Oil Not Applicable; Heat Dissipation Capacity for Refrigerant Not Applicable; Total Surface Area 60.4 sq ft; Overall Height 45 1/2 in; Overall Width 45 1/2 in; Overall Depth 25 in; Maximum Pressure Rating 200 psi; Maximum Operating Temperature 350 Degrees F; Minimum Operating Temperature -10 Degrees F; Flow Capacity 76 gpm
STANDARD XCHANGE Gasketed Plate Heat Exchanger;150 psi
Gasketed Plate Heat Exchanger; Heat Exchanger Type Plate and Frame; Mounting Stud Thread Size Not Applicable; Heat Dissipation Capacity for Water 4;909;900 BtuH; Heat Dissipation Capacity for Oil 867;800 BtuH; Heat Dissipation Capacity for Refrigerant Not Applicable; Total Surface Area 77.5 sq ft; Overall Height 34 in; Overall Width 12 1/8 in; Overall Depth 27 3/8 in; Maximum Pressure Rating 150 psi; Maximum Operating Temperature 284 Degrees F; Minimum Operating Temperature 32 Degrees F
STANDARD XCHANGE Plate Heat Exchanger Replacement Gasket
Plate Heat Exchanger Replacement Gasket; Product Type Replacement Gasket; Material Nitrile HT; Includes Not Applicable; Compatible with Manufacturer Model Number P47-115-TM; P47-161-TM; P47-95-TM; Compatible with Series P47; Compatible with Grainger Part Number 810RE9; 810RF0; 810RF1; Compatible with Brand Standard Xchange
STANDARD XCHANGE Gasketed Plate Heat Exchanger;150 psi
Gasketed Plate Heat Exchanger; Heat Exchanger Type Plate and Frame; Mounting Stud Thread Size Not Applicable; Heat Dissipation Capacity for Water 15;913;900 BtuH; Heat Dissipation Capacity for Oil 2;374;600 BtuH; Heat Dissipation Capacity for Refrigerant Not Applicable; Total Surface Area 201.5 sq ft; Overall Height 47 in; Overall Width 20 1/2 in; Overall Depth 44 1/8 in; Maximum Pressure Rating 150 psi; Maximum Operating Temperature 284 Degrees F; Minimum Operating Temperature 32 Degrees F
STANDARD XCHANGE Heat Exchanger;240;000 BtuH; 10 3/8 in L
Heat Exchanger; Heat Dissipation Capacity for Water 240;000 BtuH; Heat Dissipation Capacity for Oil 12;700 BtuH; Total Surface Area 2.4 sq ft; Shell Outside Diameter 3 1/8 in; Tube Length 10 3/8 in; Shell Material Brass; Tube Material Copper; Number of Passes 4; Shell Maximum Pressure Rating 300 psig; Shell Maximum Operating Temperature 300 Degrees F; Tube Maximum Pressure Rating 150 psig; Tube Maximum Operating Temperature 300 Degrees F; Fluid Compatibility Glycol; Oil; Steam; Water
STANDARD XCHANGE Heat Exchanger;35 1/2 in Overall H
Heat Exchanger; Heat Exchanger Type Braze Plate; Mounting Stud Thread Size Not Applicable; Heat Dissipation Capacity for Water 140;500 BtuH; Heat Dissipation Capacity for Oil Not Applicable; Heat Dissipation Capacity for Refrigerant Not Applicable; Total Surface Area 35.3 sq ft; Overall Height 35 1/2 in; Overall Width 35 1/2 in; Overall Depth 24 1/2 in; Maximum Pressure Rating 200 psi; Maximum Operating Temperature 350 Degrees F; Minimum Operating Temperature -10 Degrees F; Flow Capacity 58 gpm
STANDARD XCHANGE Gasketed Plate Heat Exchanger;150 psi
Gasketed Plate Heat Exchanger; Heat Exchanger Type Plate and Frame; Mounting Stud Thread Size Not Applicable; Heat Dissipation Capacity for Water 43;855;000 BtuH; Heat Dissipation Capacity for Oil 6;077;300 BtuH; Heat Dissipation Capacity for Refrigerant Not Applicable; Total Surface Area 620.32 sq ft; Overall Height 72 1/2 in; Overall Width 20 1/2 in; Overall Depth 45 7/8 in; Maximum Pressure Rating 150 psi; Maximum Operating Temperature 284 Degrees F; Minimum Operating Temperature 32 Degrees F
STANDARD XCHANGE Heat Exchanger;18 in Overall H
Heat Exchanger; Heat Exchanger Type Braze Plate; Mounting Stud Thread Size Not Applicable; Heat Dissipation Capacity for Water Not Applicable; Heat Dissipation Capacity for Oil 10;000 BtuH; Heat Dissipation Capacity for Refrigerant Not Applicable; Total Surface Area 3.8 sq ft; Overall Height 18 in; Overall Width 18 in; Overall Depth 19 7/8 in; Maximum Pressure Rating 200 psi; Maximum Operating Temperature 350 Degrees F; Minimum Operating Temperature -10 Degrees F; Flow Capacity 30 gpm