Filters
Cable Guided Wave Radar, Product Type Liquid Level Sensor Transmitter, Connection Size 3/4 in, For Media Type Oils, Wastewater, Water, Connection Type NPT, Body Material Aluminum, Accuracy +/-3 mm, Range 18 ft, Stem Length 216 in, Operating Pressure - Maximum 250 psi, Media Temperature - Maximum 302 Degrees F, Mounting Orientation Vertical, Enclosure Rating NEMA 4, Number of Outputs - Analog 1, Float Diameter 7/8 in, Float Length 216 in, Output Wire Configuration 3-Wire
Reflective Ultrasonic Level Sensor, For Media Type Chemicals, Oil, Wastewater, Water, Antenna Diameter 2 3/8 in, Range 235.2 in, Connection Size 2 in, Connection Type NPT, Accuracy +/-0.2 Percent of Range, Voltage - Maximum 28V DC, Dead Band 8 in, Operating Frequency 50 kHz, Spatial Resolution 0.079 in, Beam Width 3 in, Operating Pressure - Maximum 30 psi, Media Temperature - Minimum -40 Degrees F, Media Temperature - Maximum 176 Degrees F, Output Wire Configuration 2-Wire
Noncontact Radar Level Sensor, For Media Type Chemicals, Oil, Wastewater, Water, Antenna Diameter 3 7/8 in, Range 787.2 in, Connection Size 1/2 in, Connection Type NPT, Accuracy +/-3 mm, Voltage - Maximum 26V DC, Dead Band 12 in, Beam Angle 12 Degrees , Operating Frequency 26 kHz, Spatial Resolution 0.118 in, Operating Pressure - Maximum 72 psi, Media Temperature - Minimum -76 Degrees F, Media Temperature - Maximum 302 Degrees F, Output Wire Configuration 2-Wire, Output Voltage Range 4 to 20mA
Noncontact Ultrasonic Level Sensor, For Media Type Corrosive Liquid, Sticky/Waste Liquid, Antenna Diameter 2 3/8 in, Range 314.4 in, Connection Size 2 in, Connection Type NPT, Accuracy +/-0.2 Percent of Range, Voltage - Maximum 28V DC, Dead Band 8 in, Operating Frequency 50 kHz, Spatial Resolution 0.079 in, Beam Width 3 in, Operating Pressure - Maximum 30 psi, Media Temperature - Minimum -4 Degrees F, Media Temperature - Maximum 140 Degrees F, Output Wire Configuration 2-Wire
Noncontact Ultrasonic Level Sensor; For Media Type Chemicals; Oil; Wastewater; Water; Antenna Diameter 3 7/8 in; Range 1;180.8 in; Connection Size 1/2 in; Connection Type NPT; Accuracy +/-3 mm; Voltage - Maximum 26V DC; Dead Band 12 in; Beam Angle 12 Degrees ; Operating Frequency 26 kHz; Spatial Resolution 0.118 in; Media Temperature - Minimum -76 Degrees F; Media Temperature - Maximum 302 Degrees F; Output Wire Configuration 2-Wire; Output Voltage Range 4 to 20mA; Display Type LCD
Coaxial Guided Wave Radar; Product Type Liquid Level Sensor Transmitter; Connection Size 3/4 in; For Media Type Oils; Wastewater; Water; Connection Type NPT; Body Material Aluminum; Accuracy +/-3 mm; Range 9.8 ft; Stem Length 118 in; Operating Pressure - Maximum 250 psi; Media Temperature - Maximum 302 Degrees F; Mounting Orientation Vertical; Enclosure Rating NEMA 4; Number of Outputs - Analog 1; Float Diameter 7/8 in; Float Length 118 in; Output Wire Configuration 3-Wire
Reflective Ultrasonic Level Sensor; For Media Type Chemicals; Oil; Wastewater; Water; Antenna Diameter 2 3/8 in; Range 235.2 in; Connection Size 2 in; Connection Type NPT; Accuracy +/-0.2 Percent of Range; Voltage - Maximum 28V DC; Dead Band 8 in; Operating Frequency 50 kHz; Spatial Resolution 0.079 in; Beam Width 3 in; Operating Pressure - Maximum 30 psi; Media Temperature - Minimum -40 Degrees F; Media Temperature - Maximum 176 Degrees F; Output Wire Configuration 2-Wire
Noncontact Ultrasonic Level Sensor; For Media Type Corrosive Liquid; Sticky/Waste Liquid; Antenna Diameter 3 3/8 in; Range 393.6 in; Connection Size 2 in; Connection Type NPT; Accuracy +/-0.2 Percent of Range; Voltage - Maximum 24V DC; Dead Band 8 in; Operating Frequency 50 kHz; Spatial Resolution 0.079 in; Beam Width 3 in; Operating Pressure - Maximum 30 psi; Media Temperature - Minimum -4 Degrees F; Media Temperature - Maximum 140 Degrees F; Output Wire Configuration 2-Wire
Capacitance Level Switch; Product Type Liquid Level Switch; Connection Size 3/4 in; For Media Type Corrosive Liquids; Connection Type NPT; Body Material Polypropylene; Accuracy +/-1 mm; Range Not Applicable; Stem Length Not Applicable; Operating Pressure - Maximum 150 psi; Media Temperature - Maximum 176 Degrees F; Mounting Orientation Vertical; Enclosure Rating NEMA 6; Number of Outputs - Analog 1; Float Diameter 1 in; Number of Outputs - Digital 1; Float Length 5 1/2 in
Noncontact Ultrasonic Level Sensor; For Media Type Chemicals; Oil; Wastewater; Water; Antenna Diameter 3 7/8 in; Range 393.6 in; Connection Size 1 1/2 in; Connection Type NPT; Accuracy +/-5 mm; Voltage - Maximum 26V DC; Dead Band 12 in; Beam Angle 22 Degrees ; Operating Frequency 26 kHz; Spatial Resolution 0.019 in; Operating Pressure - Maximum 43.5 psi; Media Temperature - Minimum -40 Degrees F; Media Temperature - Maximum 266 Degrees F; Output Wire Configuration 2-Wire
Reflective Ultrasonic Level Sensor; For Media Type Chemicals; Oil; Wastewater; Water; Antenna Diameter 2 3/8 in; Range 58.8 in; Connection Size 2 in; Connection Type NPT; Accuracy 3 mm; Voltage - Maximum 28V DC; Dead Band 1.5 in; Operating Frequency 80 kHz; Spatial Resolution 0.019 in; Beam Width 2 in; Operating Pressure - Maximum 30 psi; Media Temperature - Minimum -40 Degrees F; Media Temperature - Maximum 176 Degrees F; Output Wire Configuration 2-Wire; Output Voltage Range 4 to 20mA
Ultrasonic Level Switch; Product Type Liquid Level Switch; Connection Size 3/4 in; For Media Type Corrosive Liquids; Connection Type NPT; Body Material Polypropylene; Accuracy +/-1 mm; Range Not Applicable; Stem Length Not Applicable; Operating Pressure - Maximum 150 psi; Media Temperature - Maximum 176 Degrees F; Mounting Orientation Horizontal; Enclosure Rating NEMA 4; Number of Outputs - Analog 1; Float Diameter 1 in; Number of Outputs - Digital 1; Float Length 4 3/4 in
Noncontact Ultrasonic Level Sensor; For Media Type Corrosive Liquid; Sticky/Dirty Liquid; Antenna Diameter 1 3/8 in; Range 49.2 in; Connection Size 1 in; Connection Type NPT; Accuracy 1/8 in; Voltage - Maximum 24V DC; Dead Band 2 in; Operating Frequency 100 kHz; Spatial Resolution 0.019 in; Beam Width 2 in; Operating Pressure - Maximum 30 psi; Media Temperature - Minimum 20 Degrees F; Media Temperature - Maximum 140 Degrees F; Output Wire Configuration 3-Wire; Display Type None
Reflective Ultrasonic Level Sensor; For Media Type Chemicals; Oil; Wastewater; Water; Antenna Diameter 2 3/8 in; Range 117.6 in; Connection Size 2 in; Connection Type NPT; Accuracy +/-0.2 Percent of Range; Voltage - Maximum 28V DC; Dead Band 4 in; Operating Frequency 80 kHz; Spatial Resolution 0.039 in; Beam Width 2 in; Operating Pressure - Maximum 30 psi; Media Temperature - Minimum -40 Degrees F; Media Temperature - Maximum 176 Degrees F; Output Wire Configuration 2-Wire
Reflective Ultrasonic Level Sensor; For Media Type Chemicals; Oil; Wastewater; Water; Antenna Diameter 3 1/2 in; Range 471.6 in; Connection Size 3 in; Connection Type NPT; Accuracy +/-0.2 Percent of Range; Voltage - Maximum 28V DC; Dead Band 18 in; Operating Frequency 50 kHz; Spatial Resolution 0.196 in; Beam Width 6 in; Operating Pressure - Maximum 30 psi; Media Temperature - Minimum -40 Degrees F; Media Temperature - Maximum 176 Degrees F; Output Wire Configuration 2-Wire
Noncontact Ultrasonic Level Sensor; For Media Type Chemicals; Oil; Wastewater; Water; Antenna Diameter 3 7/8 in; Range 1;180.8 in; Connection Size 1 1/2 in; Connection Type NPT; Accuracy +/-3 mm; Voltage - Maximum 26V DC; Dead Band 12 in; Beam Angle 12 Degrees ; Operating Frequency 26 kHz; Spatial Resolution 0.118 in; Operating Pressure - Maximum 150 psi; Media Temperature - Minimum -76 Degrees F; Media Temperature - Maximum 302 Degrees F; Output Wire Configuration 2-Wire
Noncontact Ultrasonic Level Sensor; For Media Type Corrosive Liquid; Sticky/Dirty Liquid; Antenna Diameter 2 3/8 in; Range 314.4 in; Connection Size 2 in; Connection Type NPT; Accuracy 0.25 in; Voltage - Maximum 250V DC; Dead Band 8 in; Operating Frequency 50 kHz; Spatial Resolution 0.25 in; Beam Width 3 in; Operating Pressure - Maximum 30 psi; Media Temperature - Minimum -7 Degrees F; Media Temperature - Maximum 140 Degrees F; Output Wire Configuration 4-Wire; Output Voltage Range 4 to 20mA
Reflective Ultrasonic Level Sensor; For Media Type Chemicals; Oil; Wastewater; Water; Antenna Diameter 3 1/2 in; Range 471.6 in; Connection Size 3 in; Connection Type NPT; Accuracy +/-0.2 Percent of Range; Voltage - Maximum 28V DC; Dead Band 18 in; Operating Frequency 50 kHz; Spatial Resolution 0.196 in; Beam Width 6 in; Operating Pressure - Maximum 30 psi; Media Temperature - Minimum -40 Degrees F; Media Temperature - Maximum 176 Degrees F; Output Wire Configuration 2-Wire
Noncontact Ultrasonic Level Sensor; For Media Type Chemicals; Oil; Wastewater; Water; Antenna Diameter 1 3/8 in; Range 49.2 in; Connection Size 1 in; Connection Type NPT; Accuracy 1/8 in; Voltage - Maximum 24V DC; Dead Band 2 in; Operating Frequency 100 kHz; Spatial Resolution 0.019 in; Beam Width 2 in; Operating Pressure - Maximum 30 psi; Media Temperature - Minimum 20 Degrees F; Media Temperature - Maximum 140 Degrees F; Output Wire Configuration 2-Wire; Output Voltage Range 4 to 20mA
Reflective Ultrasonic Level Sensor; For Media Type Chemicals; Oil; Wastewater; Water; Antenna Diameter 3 1/2 in; Range 471.6 in; Connection Size 3 in; Connection Type NPT; Accuracy +/-0.2 Percent of Range; Voltage - Maximum 28V DC; Dead Band 18 in; Operating Frequency 50 kHz; Spatial Resolution 0.196 in; Beam Width 6 in; Operating Pressure - Maximum 30 psi; Media Temperature - Minimum -40 Degrees F; Media Temperature - Maximum 176 Degrees F; Output Wire Configuration 2-Wire
Noncontact Ultrasonic Level Sensor; For Media Type Corrosive Liquid; Sticky/Waste Liquid; Antenna Diameter 1 3/8 in; Range 117.6 in; Connection Size 1 in; Connection Type NPT; Accuracy +/-0.2 Percent of Range; Voltage - Maximum 24V DC; Dead Band 4 in; Operating Frequency 100 kHz; Spatial Resolution 0.019 in; Beam Width 2 in; Operating Pressure - Maximum 30 psi; Media Temperature - Minimum -4 Degrees F; Media Temperature - Maximum 140 Degrees F; Output Wire Configuration 2-Wire
Reflective Ultrasonic Level Sensor; For Media Type Chemicals; Oil; Wastewater; Water; Antenna Diameter 2 3/8 in; Range 117.6 in; Connection Size 2 in; Connection Type NPT; Accuracy +/-0.2 Percent of Range; Voltage - Maximum 28V DC; Dead Band 4 in; Operating Frequency 80 kHz; Spatial Resolution 0.039 in; Beam Width 2 in; Operating Pressure - Maximum 30 psi; Media Temperature - Minimum -40 Degrees F; Media Temperature - Maximum 176 Degrees F; Output Wire Configuration 2-Wire
Side Mount Bracket; Product Type Mounting Bracket; Compatible Manufacturer Part Number DL10-01; DL14-01; DL24-01; DS14-01; DX14-01; LU27-01; LU77-5005; LU80-5101
Level Controller; Application General Purpose; Contact Rating 3 A @ 30V DC; Contact Type SPDT; Display Type LED; Enclosure Material Polycarbonate; Enclosure Rating NEMA 4X; IP 65; Height 5.64 in; Manufacturers Warranty Length 3 yr; Maximum Operating Temperature 149 Degrees F; Minimum Operating Temperature -40 Degrees F; Mounting Panel Mount
Noncontact Ultrasonic Level Sensor; For Media Type Chemicals; Oil; Wastewater; Water; Antenna Diameter 3 7/8 in; Range 1;180.8 in; Connection Size 1 1/2 in; Connection Type NPT; Accuracy +/-3 mm; Voltage - Maximum 26V DC; Dead Band 12 in; Beam Angle 18 Degrees ; Operating Frequency 26 kHz; Spatial Resolution 0.118 in; Operating Pressure - Maximum 150 psi; Media Temperature - Minimum -76 Degrees F; Media Temperature - Maximum 302 Degrees F; Output Wire Configuration 2-Wire
Dessicant Filter; Series LD90; Compatible Brand and Series DeltaSpan LD32 GP Pump Lift Station Pressure Level Transmitter; Flowline LD31-S101; Flowline LD31-S111; Flowline LD31-S131; Features Protection Against Humidity
Reflective Ultrasonic Level Sensor; For Media Type Chemicals; Oil; Wastewater; Water; Antenna Diameter 2 3/8 in; Range 58.8 in; Connection Size 2 in; Connection Type NPT; Accuracy 3 mm; Voltage - Maximum 28V DC; Dead Band 1.5 in; Operating Frequency 80 kHz; Spatial Resolution 0.019 in; Beam Width 2 in; Operating Pressure - Maximum 30 psi; Media Temperature - Minimum -40 Degrees F; Media Temperature - Maximum 176 Degrees F; Output Wire Configuration 2-Wire; Output Voltage Range 4 to 20mA
Reflective Ultrasonic Level Sensor; For Media Type Chemicals; Oil; Wastewater; Water; Antenna Diameter 2 3/8 in; Range 235.2 in; Connection Size 2 in; Connection Type NPT; Accuracy +/-0.2 Percent of Range; Voltage - Maximum 28V DC; Dead Band 8 in; Operating Frequency 50 kHz; Spatial Resolution 0.079 in; Beam Width 3 in; Operating Pressure - Maximum 30 psi; Media Temperature - Minimum -40 Degrees F; Media Temperature - Maximum 176 Degrees F; Output Wire Configuration 2-Wire
Reflective Ultrasonic Level Sensor; For Media Type Chemicals; Oil; Wastewater; Water; Antenna Diameter 2 3/8 in; Range 235.2 in; Connection Size 2 in; Connection Type NPT; Accuracy +/-0.2 Percent of Range; Voltage - Maximum 28V DC; Dead Band 8 in; Operating Frequency 50 kHz; Spatial Resolution 0.079 in; Beam Width 3 in; Operating Pressure - Maximum 30 psi; Media Temperature - Minimum -40 Degrees F; Media Temperature - Maximum 176 Degrees F; Output Wire Configuration 2-Wire
Noncontact Ultrasonic Level Sensor; For Media Type Corrosive Liquid; Sticky/Waste Liquid; Ultrapure Liquid; Antenna Diameter 1 3/8 in; Range 117.6 in; Connection Size 1 in; Connection Type NPT; Accuracy +/-0.2 Percent of Range; Voltage - Maximum 28V DC; Dead Band 4 in; Operating Frequency 100 kHz; Spatial Resolution 0.019 in; Beam Width 2 in; Operating Pressure - Maximum 30 psi; Media Temperature - Minimum -7 Degrees F; Media Temperature - Maximum 140 Degrees F; Output Wire Configuration 2-Wire