Close
Noble
Free Shipping on orders over $100 - CONUS ONLY
Home
Filters
Apply Filters

NARROW DOWN


CONTRACT
-

47QSCCD0007


COUNTRY_OF_ORIGIN
-

Japan


BRAND
-
GASTEC Tube,Carbon Dioxide,100-4000,PK10
Detector Tube, Measurement Range 100 to 4,000 ppm, Gas Detected Carbon Dioxide, For Use With Gastec Pump, Color Change Pale Orange Red to Orange, Operating Pressure 912 to 1,114 hPa, Operating Temperature - Minimum 32 Degrees F, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Sampling Method With Pump, Shelf Life 2 yr, Application Industrial Safety and Health, Sampling Time 2 min (100 to 2,000 ppm), Sampling Volume 100 mL (1 Pump Stroke)
GASTEC Tube,Hydrogen,0.5-2,PK10
Detector Tube, Measurement Range 0.5 to 2 Percent, Gas Detected Hydrogen, For Use With Gastec Pump, Color Change Yellow to Yellowish Brown, Operating Pressure 912 to 1,114 hPa, Operating Temperature - Minimum 32 Degrees F, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Sampling Method With Pump, Shelf Life 3 yr, Application Industrial Safety and Health, Sampling Time 3 min (0.5 to 2 Percent vol), Sampling Volume 100 mL (1 Pump Stroke)
GASTEC Detector Tube,Propane,PK10
Detector Tube, Measurement Range 0.1 to 2 Percent vol, Gas Detected Propane, For Use With No. 611 Syringe, Color Change Yellowish Brown to Greenish Brown, Operating Pressure 912 to 1,114 hPa, Operating Temperature - Minimum 32 Degrees F, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Sampling Method With Pump, Shelf Life 3 yr, Application Industrial Safety and Health, Sampling Time 2 min (0.1 to 2 Percent vol), Sampling Volume 20 mL
GASTEC Formaldehyde Detector Tube,PK10
Detector Tube, Measurement Range 2 to 100 ppm, Gas Detected Formaldehyde, For Use With Mfr. No. GV-100-SOHA-TR, Mfr. No. GV-110-S-TR, Mfr. No. GV-110-SOHA-TR, Color Change White to Brown, Operating Pressure Ambient, Operating Temperature - Minimum 32 Degrees F, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Sampling Method With Pump, Shelf Life 3 yr, Application Industrial Safety and Health, Sampling Time 1.5 min (2 to 20 ppm)
GASTEC Tube,Methyl Alcohol,200-1000,PK10
Detector Tube, Measurement Range 20 to 1,000 ppm, Gas Detected Methanol, For Use With Gastec Pump, Color Change Pale Orange Red to Pale Blue, Operating Pressure 912 to 1,114 hPa, Operating Temperature - Minimum 32 Degrees F, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Sampling Method With Pump, Shelf Life 3 yr, Application Industrial Safety and Health, Sampling Time 2 min (40 to 1,000 ppm), Sampling Volume 100 mL (1 Pump Stroke)
GASTEC Tube,Gasoline,30-2000,PK10
Detector Tube, Measurement Range 30 to 2,000 ppm, Gas Detected Gasoline, For Use With Gastec Pump, Color Change Yellowish Brown to Greenish Brown, Operating Pressure 912 to 1,114 hPa, Operating Temperature - Minimum 32 Degrees F, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Sampling Method With Pump, Shelf Life 3 yr, Application Industrial Safety and Health, Sampling Time 4 min (30 to 1,000 ppm), Sampling Volume 200 mL (2 Pump Stroke)
GASTEC Gas Sampling Pump,Plastic
Gas Sampling Pump, Gas Detected Chemical Substances, Product Type Detection Tube Pump Kit, Power Source Manual/Non-Powered, Includes (3) Rubber Inlets, Lubricant, Features Adjustable Sampling Volume, Calibrated Scale Directly Printed On The Tube, Each Detector Tube Has Its Own Quality Control Number Printed On The Tube, Long Shelf-Life, On-Site Measurements, Housing Material Plastic, Overall Length 10 in, Series GV-100
GASTEC Tube,Acetaldehyde,2.5 to 100ppm,PK10
Detector Tube, Measurement Range 2.5 to 100 ppm, Gas Detected Acetaldehyde, For Use With Mfr. No. 70510, Mfr. No. GV-100-SOHA-TR, Mfr. No. GV-110-S-TR, Mfr. No. GV-110-SOHA-TR, Color Change Yellow to Red, Operating Pressure Ambient, Operating Temperature - Minimum 32 Degrees F, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Sampling Method With Pump, Shelf Life 2 yr, Application Industrial Safety and Health, Sampling Time 1 min (5 to 100 ppm)
GASTEC Tube,Carbon Dioxide,0.13-6,PK10
Detector Tube, Measurement Range 0.13 to 6 Percent, Gas Detected Carbon Dioxide, For Use With Gastec Pump, Color Change White to Purple, Operating Pressure 912 to 1,114 hPa, Operating Temperature - Minimum 32 Degrees F, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Sampling Method With Pump, Shelf Life 3 yr, Application Industrial Safety and Health, Sampling Time 1.5 min (0.25 to 3 Percent vol), Sampling Volume 100 mL (1 Pump Stroke)
GASTEC Tube,Methyl Chloroform*,7-660,PK10
Detector Tube, Measurement Range 6 to 900 ppm, Gas Detected Methyl Chloroform, For Use With Gastec Pump, Color Change White to Pale Pink, Operating Pressure 912 to 1,114 hPa, Operating Temperature - Minimum 32 Degrees F, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Sampling Method With Pump, Shelf Life 27 mo, Application Industrial Safety and Health, Sampling Time 3 min (20 to 200 ppm), Sampling Volume 100 mL (1 Pump Stroke), Chemical Formula C2H3Cl3
GASTEC Carbon Monoxide Dosimeter;1.04-2000;PK10
Detector Tube; Measurement Range 1.04 to 2;000 ppm; Gas Detected Carbon Monoxide; For Use With Dosiholder; Color Change Pale Yellow to Brown; Operating Pressure 912 to 1;114 hPa; Operating Temperature - Minimum 32 Degrees F; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Shelf Life 2 yr; Application Industrial Safety and Health; Sampling Time 0.5 to 48 hr (1.04 to 2;000 ppm); Chemical Formula CO; Operating Temperature - Maximum 104 Degrees F
GASTEC Perc Tetrachloroethylene Dosimeter;PK10
Detector Tube; Measurement Range 3 to 150 ppm; Gas Detected Tetrachloroethylene; For Use With Dosiholder; Color Change Yellow to Purple; Operating Pressure 912 to 1;114 hPa; Operating Temperature - Minimum 32 Degrees F; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Shelf Life 15 mo; Application Industrial Safety and Health; Sampling Time 1 to 8 hr (3 to 150 ppm); Chemical Formula C2Cl4; Operating Temperature - Maximum 104 Degrees F; Package Quantity 10
GASTEC Formaldehyde Gas Sampling Tube;PK10
Detector Tube; Measurement Range 0.01 to 1.75 ppm; Gas Detected Formaldehyde; For Use With Mfr. No. GV-100-SOHA-TR; Mfr. No. GV-110-S-TR; Mfr. No. GV-110-SOHA-TR; Color Change Yellow to Pale Orange; Operating Pressure Ambient; Operating Temperature - Minimum 41 Degrees F; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Shelf Life 1 yr; Application Industrial Safety and Health; Sampling Time 10 min (0.01 to 0.50 ppm); Sampling Volume 1;000 mL
GASTEC Tube;Carbon Monoxide;5-50;PK10
Detector Tube; Measurement Range 5 to 50 ppm; Gas Detected Carbon Monoxide; For Use With Gastec Pump; Color Change Yellow to Blackish Brown; Operating Pressure 912 to 1;114 hPa; Operating Temperature - Minimum 32 Degrees F; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Sampling Method With Pump; Shelf Life 3 yr; Application Industrial Safety and Health; Sampling Time 6 min (5 to 50 ppm); Sampling Volume 200 mL (2 Pump Stroke); Chemical Formula CO
GASTEC Hydrogen Sulfide Detctor Tube;PK10
Detector Tube; Measurement Range 0.25 to 20 Percent vol; Gas Detected Hydrogen Sulphide; For Use With Mfr. No. GV-100-SOHA-TR; Mfr. No. GV-110-S-TR; Mfr. No. GV-110-SOHA-TR; Color Change Pale Blue to Blackish Brown; Operating Pressure Ambient; Operating Temperature - Minimum 32 Degrees F; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Sampling Method With Pump; Shelf Life 3 yr; Application Industrial Safety and Health
GASTEC Hydrogen Cyanide Dosimeter;1-200;PK10
Detector Tube; Measurement Range 1 to 200 ppm; Gas Detected Hydrogen Cyanide; For Use With Dosiholder; Color Change Yellow to Pink; Operating Pressure 912 to 1;114 hPa; Operating Temperature - Minimum 32 Degrees F; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Shelf Life 2 yr; Application Industrial Safety and Health; Sampling Time 1 to 10 hr (1 to 200 ppm); Chemical Formula HCN; Operating Temperature - Maximum 104 Degrees F; Package Quantity 10
GASTEC Hydrogen Sulfide Odorant Tube;PK10
Detector Tube; Measurement Range 10 to 200 ppb; Gas Detected Hydrogen Sulphide; For Use With Mfr. No. GV-100-SOHA-TR; Mfr. No. GV-110-S-TR; Mfr. No. GV-110-SOHA-TR; Color Change Yellow to Purple; Operating Pressure Ambient; Operating Temperature - Minimum 32 Degrees F; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Shelf Life 1.5 yr; Application Industrial Safety and Health; Sampling Time 5 min (10 to 200 ppb); Chemical Formula H2S
GASTEC Carbon Monoxide Detector Tube;PK10
Detector Tube; Measurement Range 0.05 to 4 Percent; Gas Detected Carbon Monoxide; For Use With Mfr. No. GV-100-SOHA-TR; Mfr. No. GV-110-S-TR; Mfr. No. GV-110-SOHA-TR; Color Change White to Pale Brown; Operating Pressure Ambient; Operating Temperature - Minimum 32 Degrees F; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Sampling Method With Pump; Shelf Life 3 yr; Application Industrial Safety and Health; Sampling Time 1 min (0.1 to 2 Percent vol)
GASTEC Tube;Sulfr Dioxide;0.5 to 60ppm;PK10
Detector Tube; Measurement Range 0.5 to 60 ppm; Gas Detected Sulfur Dioxide; For Use With Mfr. No. 73234; Mfr. No. GV-100-SOHA-TR; Mfr. No. GV-110-S-TR; Mfr. No. GV-110-SOHA-TR; Color Change Blue to Yellow; Operating Pressure Ambient; Operating Temperature - Minimum 32 Degrees F; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Sampling Method With Pump; Shelf Life 3 yr; Application Industrial Safety and Health; Sampling Time 2 min (2 to 30 ppm)
GASTEC Benzene Automatic Gas Sampling Tube;PK10
Detector Tube; Measurement Range 250 to 3;000 micron g/m3; Gas Detected Benzene; For Use With Mfr. No. GV-100-SOHA-TR; Mfr. No. GV-110-S-TR; Mfr. No. GV-110-SOHA-TR; Color Change White to Brown; Operating Pressure Ambient; Operating Temperature - Minimum 32 Degrees F; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Shelf Life 30 mo; Application Industrial Safety and Health; Sampling Time 60 min (250 to 3;000 microng/m); Sampling Volume 3;000 mL
GASTEC Detector Tube;Methanol;2 to 56 ppm;PK10
Detector Tube; Measurement Range 2 to 62 ppm; Gas Detected Methanol; For Use With Mfr. No. 71640; Mfr. No. GV-100-SOHA-TR; Mfr. No. GV-110-S-TR; Mfr. No. GV-110-SOHA-TR; Color Change Pale Yellow to Pale Bluish Green; Operating Pressure Ambient; Operating Temperature - Minimum 32 Degrees F; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Sampling Method With Pump; Shelf Life 2 yr; Application Industrial Safety and Health; Sampling Time 8 min (2 to 20 ppm)
GASTEC Tube;Sulfur Dioxide;20-3600;PK10
Detector Tube; Measurement Range 20 to 3600 ppm; Gas Detected Sulphur Dioxide; For Use With Gastec Pump; Color Change Purple to Yellow; Operating Pressure 912 to 1;114 hPa; Operating Temperature - Minimum 32 Degrees F; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Sampling Method With Pump; Shelf Life 3 yr; Application Industrial Safety and Health; Sampling Time 45 min (100 to 1;800 ppm); Sampling Volume 100 mL (1 Pump Stroke); Chemical Formula SO2
GASTEC Gas Sampling Pump;Plastic
Gas Sampling Pump; Gas Detected Chemical Substances; Product Type Detection Tube Pump Kit; Power Source Manual/Non-Powered; Includes (3) Rubber Inlets; Lubricant; Features Adjustable Sampling Volume; Calibrated Scale Directly Printed On The Tube; Each Detector Tube Has Its Own Quality Control Number Printed On The Tube; Long Shelf-Life; On-Site Measurements; For Use With All Nextteq Gas Detection Tubes; Housing Material Plastic; Overall Length Not Applicable; Series GV-110
GASTEC Tube;Hydrgen Sulfide;1 to 40ppm;PK10
Detector Tube; Measurement Range 1 to 40 ppm; Gas Detected Hydrogen Sulphide; For Use With Mfr. No. 70180; Mfr. No. GV-100-SOHA-TR; Mfr. No. GV-110-S-TR; Mfr. No. GV-110-SOHA-TR; Color Change White to Brown; Operating Pressure Ambient; Operating Temperature - Minimum 32 Degrees F; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Sampling Method With Pump; Shelf Life 3 yr; Application Industrial Safety and Health; Sampling Time 1 min (2 to 20 ppm)
GASTEC Tube;Water Vapor;0.5-32mg/L;PK10
Detector Tube; Measurement Range 0.5 to 32 mg/L; Gas Detected Water Vapor; For Use With Gastec Pump; Color Change Yellowish Green to Purple; Operating Pressure 912 to 1;114 hPa; Operating Temperature - Minimum 50 Degrees F; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Sampling Method With Pump; Shelf Life 3 yr; Application Industrial Safety and Health; Sampling Time 45 min (1 to 18 mg/L); Sampling Volume 100 mL (1 Pump Stroke); Chemical Formula H2O
GASTEC Tube;Hydrazine;0.05-2;PK10
Detector Tube; Measurement Range 0.04 to 2 ppm; Gas Detected Hydrazine; For Use With Gastec Pump; Color Change Pink to Yellow; Operating Pressure 912 to 1;114 hPa; Operating Temperature - Minimum 32 Degrees F; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Sampling Method With Pump; Shelf Life 3 yr; Application Industrial Safety and Health; Sampling Time 5 min (0.1 to 2 ppm); Sampling Volume 500 mL (5 Pump Stroke); Chemical Formula N2H4
GASTEC Tube;Stoddard Solvent;50-8000mg/m3;PK10
Detector Tube; Measurement Range 50 to 8;000 mg/m3; Gas Detected Stoddard Solvent; For Use With Gastec Pump; Color Change White to Brown; Operating Pressure 912 to 1;114 hPa; Operating Temperature - Minimum 32 Degrees F; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Sampling Method With Pump; Shelf Life 3 yr; Application Industrial Safety and Health; Sampling Time 1.5 min (50 to 8;000 mg/m3); Sampling Volume 100 mL (1 Pump Stroke)
GASTEC Tube;Water Vapor;500 to 5000ppm;PK10
Detector Tube; Measurement Range 500 to 5;000 ppm; Gas Detected Water Vapor; For Use With Mfr. No. 73151; Mfr. No. GV-100-SOHA-TR; Mfr. No. GV-110-S-TR; Mfr. No. GV-110-SOHA-TR; Color Change Green to Purple; Operating Pressure Ambient; Operating Temperature - Minimum 32 Degrees F; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Shelf Life 3 yr; Application Industrial Safety and Health; Sampling Time 1 min (500 to 5;000 ppm); Sampling Volume 300 mL
GASTEC Tube;Amines;1-280;PK10
Detector Tube; Measurement Range 5 to 100 ppm; Gas Detected Amines; For Use With Gastec Pump; Operating Pressure 912 to 1;114 hPa; Operating Temperature - Minimum 32 Degrees F; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Sampling Method With Pump; Shelf Life 3 yr; Application Industrial Safety and Health; Sampling Time 30 sec (5 to 100 ppm); Sampling Volume 100 mL (1 Pump Stroke); Chemical Formula R¿NH2; Operating Temperature - Maximum 104 Degrees F
GASTEC Sulfur Dioxide Detector Tube;PK10
Detector Tube; Measurement Range 0.1 to 22 ppm; Gas Detected Sulphur Dioxide; For Use With Mfr. No. GV-100-SOHA-TR; Mfr. No. GV-110-S-TR; Mfr. No. GV-110-SOHA-TR; Color Change Blue Purple to White; Operating Pressure Ambient; Operating Temperature - Minimum 32 Degrees F; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Sampling Method With Pump; Shelf Life 3 yr; Application Industrial Safety and Health; Sampling Time 4 min (0.25 to 10 ppm)