Close
Noble
Free Shipping on orders over $100 - CONUS ONLY
Home
Filters
Apply Filters

NARROW DOWN


COUNTRY_OF_ORIGIN
-

China

Czech Republic

France

Indonesia

Thailand


CONTRACT
-

47QSCCD0007


PROP_65_INDICATOR
-

Y


BRAND
-
SCHNEIDER IECMagContactor, NonReversing, 240VAC
IEC Magnetic Contactor, Auxiliary Contact Form 1NO, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 240V AC, Number of Poles 3, Full Load Current - Inductive 32 A, Reversing Capability Non-Reversing, Overall Height 3.35 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Easy, Number of Auxillary Contacts 1, Contactor Style IEC, Horsepower @ Three Phase - 240V AC 7 1/2 hp
SCHNEIDER Force,DIN Rail,4.72" D,3.94" H,0.89"W,2W
Force, Delay Time 0.5 sec, 2 sec, 4 sec, Delay Type Adjustable, Electrical Connection Screw Terminal, Terminal Block Removable, IP Rating IP20; IP40; IP54, Input Voltage 24V AC/DC, Mounting Style DIN Rail, Number of Inputs 2, Response Time 20 msec, Standards CCC, cULus Listed, EAC, IEC 60947-5-1, IEC 61508-1/2/3, IEC 62061, ISO 13849-1, TUV Certified, Contact Rating (AC) 1 A @ 15V (NC), 3 A @ 1V (NC), 3 A @ 15V (NO), 5 A @ 1V (NO)
SCHNEIDER IECMagContactor; NonReversing; 120VAC
IEC Magnetic Contactor; Auxiliary Contact Form 1NO; NEMA Enclosure Rating No Enclosure; NEMA Size Not Applicable; Coil Voltage 120V AC; Number of Poles 3; Full Load Current - Inductive 18 A; Full Load Current - Resistive 18 A; Reversing Capability Non-Reversing; Overall Height 3.03 in; Overall Width 1.77 in; Terminal Connection Type Screw Clamp Terminals; Mounting Style DIN Rail; Plate; Series TeSys Easy; Number of Auxillary Contacts 1; Contactor Style IEC
SCHNEIDER IECMagneticContactor,NonReversing,24VDC
IEC Magnetic Contactor, Auxiliary Contact Form 1NO, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V DC, Number of Poles 3, Full Load Current - Inductive 9 A, Full Load Current - Resistive 9 A, Reversing Capability Non-Reversing, Overall Height 3.03 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Easy, Number of Auxillary Contacts 1, Contactor Style IEC, Horsepower @ Three Phase - 240V AC 2 hp
SCHNEIDER IECMagneticContactor;NonReversing;24VAC
IEC Magnetic Contactor; Auxiliary Contact Form 1NO; NEMA Enclosure Rating No Enclosure; NEMA Size Not Applicable; Coil Voltage 24V AC; Number of Poles 3; Full Load Current - Inductive 18 A; Full Load Current - Resistive 18 A; Reversing Capability Non-Reversing; Overall Height 3.03 in; Overall Width 1.77 in; Terminal Connection Type Screw Clamp Terminals; Mounting Style DIN Rail; Plate; Series TeSys Easy; Number of Auxillary Contacts 1; Contactor Style IEC; Horsepower @ Three Phase - 240V AC 3 hp
SCHNEIDER OverloadRelay; IEC; Thermal; Auto/Manual
IEC Overload Relay; Auxiliary Contact Form 1NO/1NC; Maximum Overload Relay Current Setting 0.4 A; Minimum Overload Relay Current Setting 0.25 A; Trip Class 10; Maximum Voltage Rating 690V AC; NEMA Size Not Applicable; Number of Poles 3; Reset Type Auto; Manual; Mounting Style Separately Mounted; Terminal Connection Type Screw Clamp Terminals; Compatible with Series Easy TeSys; Relay Style IEC; Overload Protection Type Thermal; Phase Three
SCHNEIDER ManualMotorStarter;IEC;PushButton;Therm
Manual Motor Starter; NEMA Size Not Applicable; Horsepower @ Single Phase - 120V AC 2 hp; Horsepower @ Single Phase - 240V AC 5 hp; Maximum Voltage Rating 690V AC; Number of Poles 3; Operator Push Button; Phase Three; Current AC 32 A; Horsepower @ Three Phase - 208V AC 7 1/2 hp; Horsepower @ Three Phase - 240V AC 10 hp; Horsepower @ Three Phase - 480V AC 20 hp; Series TeSys Easy; Horsepower @ Three Phase - 600V AC 25 hp; Maximum Overload Relay Current Setting 32 A
SCHNEIDER IECMagneticContactor;NonReversing;24VAC
IEC Magnetic Contactor; Auxiliary Contact Form Auxiliary Contacts Not Included; NEMA Enclosure Rating No Enclosure; NEMA Size Not Applicable; Coil Voltage 24V AC; Number of Poles 3; Full Load Current - Inductive 38 A; Full Load Current - Resistive 38 A; Reversing Capability Non-Reversing; Overall Height 3.35 in; Overall Width 1.77 in; Terminal Connection Type Screw Clamp Terminals; Mounting Style DIN Rail; Plate; Series TeSys Easy; Number of Auxillary Contacts 0; Contactor Style IEC
SCHNEIDER OverloadRelay; IEC; Thermal; Auto/Manual
IEC Overload Relay; Auxiliary Contact Form 1NO/1NC; Maximum Overload Relay Current Setting 8 A; Minimum Overload Relay Current Setting 5.5 A; Trip Class 10; Maximum Voltage Rating 690V AC; NEMA Size Not Applicable; Number of Poles 3; Reset Type Auto; Manual; Mounting Style Separately Mounted; Terminal Connection Type Screw Clamp Terminals; Compatible with Series Easy TeSys; Relay Style IEC; Overload Protection Type Thermal; Phase Three
SCHNEIDER IECMagneticContactor;NonReversing;24VAC
IEC Magnetic Contactor; Auxiliary Contact Form 1NO; NEMA Enclosure Rating No Enclosure; NEMA Size Not Applicable; Coil Voltage 24V AC; Number of Poles 3; Full Load Current - Inductive 9 A; Full Load Current - Resistive 9 A; Reversing Capability Non-Reversing; Overall Height 3.03 in; Overall Width 1.77 in; Terminal Connection Type Screw Clamp Terminals; Mounting Style DIN Rail; Plate; Series TeSys Easy; Number of Auxillary Contacts 1; Contactor Style IEC; Horsepower @ Three Phase - 240V AC 2 hp
SCHNEIDER ManualMotorStarter;IEC;PushButton;Therm
Manual Motor Starter; NEMA Size Not Applicable; Horsepower @ Single Phase - 120V AC 1 1/2 hp; Horsepower @ Single Phase - 240V AC 3 hp; Maximum Voltage Rating 690V AC; Number of Poles 3; Operator Push Button; Phase Three; Current AC 23 A; Horsepower @ Three Phase - 208V AC 5 hp; Horsepower @ Three Phase - 240V AC 7 1/2 hp; Horsepower @ Three Phase - 480V AC 15 hp; Series TeSys Easy; Horsepower @ Three Phase - 600V AC 20 hp; Maximum Overload Relay Current Setting 23 A
SCHNEIDER ManualMotorStarter;IEC;PushButton;Therm
Manual Motor Starter; NEMA Size Not Applicable; Maximum Voltage Rating 690V AC; Number of Poles 3; Operator Push Button; Phase Three; Current AC 0.4 A; Series TeSys Easy; Maximum Overload Relay Current Setting 0.4 A; Minimum Overload Relay Current Setting 0.25 A; Mounting Style DIN Rail; NEMA Enclosure Rating No Enclosure; Number of Required Thermals Not Applicable; Overload Protection Type Thermal; Starter Style IEC; Terminal Connection Type Screw Clamp Terminals; IP Rating IP20
SCHNEIDER IECMagContactor; NonReversing; 240VAC
IEC Magnetic Contactor; Auxiliary Contact Form 1NO; NEMA Enclosure Rating No Enclosure; NEMA Size Not Applicable; Coil Voltage 240V AC; Number of Poles 3; Full Load Current - Inductive 25 A; Full Load Current - Resistive 25 A; Reversing Capability Non-Reversing; Overall Height 3.03 in; Overall Width 1.77 in; Terminal Connection Type Screw Clamp Terminals; Mounting Style DIN Rail; Plate; Series TeSys Easy; Number of Auxillary Contacts 1; Contactor Style IEC
SCHNEIDER IECMagContactor; NonReversing; 120VAC
IEC Magnetic Contactor; Auxiliary Contact Form 1NO; NEMA Enclosure Rating No Enclosure; NEMA Size Not Applicable; Coil Voltage 120V AC; Number of Poles 3; Full Load Current - Inductive 25 A; Full Load Current - Resistive 25 A; Reversing Capability Non-Reversing; Overall Height 3.03 in; Overall Width 1.77 in; Terminal Connection Type Screw Clamp Terminals; Mounting Style DIN Rail; Plate; Series TeSys Easy; Number of Auxillary Contacts 1; Contactor Style IEC
SCHNEIDER ManualMotorStarter;IEC;PushButton;Therm
Manual Motor Starter; NEMA Size Not Applicable; Maximum Voltage Rating 690V AC; Number of Poles 3; Operator Push Button; Phase Three; Current AC 1 A; Series TeSys Easy; Horsepower @ Three Phase - 600V AC 1/2 hp; Maximum Overload Relay Current Setting 1 A; Minimum Overload Relay Current Setting 0.63 A; Mounting Style DIN Rail; NEMA Enclosure Rating No Enclosure; Number of Required Thermals Not Applicable; Overload Protection Type Thermal; Starter Style IEC
SCHNEIDER OverloadRelay; IEC; Thermal; Auto/Manual
IEC Overload Relay; Auxiliary Contact Form 1NO/1NC; Maximum Overload Relay Current Setting 4 A; Minimum Overload Relay Current Setting 2.5 A; Trip Class 10; Maximum Voltage Rating 690V AC; NEMA Size Not Applicable; Number of Poles 3; Reset Type Auto; Manual; Mounting Style Separately Mounted; Terminal Connection Type Screw Clamp Terminals; Compatible with Series Easy TeSys; Relay Style IEC; Overload Protection Type Thermal; Phase Three
SCHNEIDER OverloadRelay; IEC; Thermal; Auto/Manual
IEC Overload Relay; Auxiliary Contact Form 1NO/1NC; Maximum Overload Relay Current Setting 0.16 A; Minimum Overload Relay Current Setting 0.1 A; Trip Class 10A; Maximum Voltage Rating 690V AC; NEMA Size Not Applicable; Number of Poles 3; Reset Type Auto; Manual; Mounting Style Separately Mounted; Terminal Connection Type Screw Clamp Terminals; Compatible with Series Easy TeSys; Relay Style IEC; Overload Protection Type Thermal; Phase Three
SCHNEIDER Safety Relay Extension Module;24 V AC/DC
Force; Delay Time None; Delay Type Fixed; Electrical Connection Screw Terminal; Terminal Block Removable; IP Rating IP20; IP40; IP54; Input Voltage 24V AC/DC; Mounting Style DIN Rail; Number of Inputs 2; Number of Pins 16; Output Switch Configuration (3) NO; Response Time 20 msec; Standards CCC; cULus Listed; EAC; IEC 60947-5-1; IEC 61508-1/2/3; IEC 62061; ISO 13849-1; TUV Certified; Contact Rating (AC) 8 A @ 250V
SCHNEIDER Force;DIN Rail;4.72"D;3.94"H;1.77"W;4.5W
Force; Delay Time 0.5 sec; 2 sec; 4 sec; Delay Type Adjustable; Electrical Connection Screw Terminal; Terminal Block Removable; IP Rating IP20; IP40; IP54; Input Voltage 24V AC/DC; Mounting Style DIN Rail; Response Time 20 msec; Standards CCC; cULus Listed; EAC; IEC 60947-5-1; IEC 61508-1/2/3; IEC 62061; ISO 13849-1; TUV Certified; Contact Rating (AC) 1 A @ 15V (NC); 3 A @ 1V (NC); 3 A @ 15V (NO); 5 A @ 1V (NO); Contact Rating (DC) 1 A @ 13V (NC); 3 A @ 1V (NC); 3 A @ 13V (NO); 5 A @ 1V (NO)
SCHNEIDER IECMagContactor; NonReversing; 120VAC
IEC Magnetic Contactor; Auxiliary Contact Form 1NO; NEMA Enclosure Rating No Enclosure; NEMA Size Not Applicable; Coil Voltage 120V AC; Number of Poles 3; Full Load Current - Inductive 12 A; Full Load Current - Resistive 12 A; Reversing Capability Non-Reversing; Overall Height 3.03 in; Overall Width 1.77 in; Terminal Connection Type Screw Clamp Terminals; Mounting Style DIN Rail; Plate; Series TeSys Easy; Number of Auxillary Contacts 1; Contactor Style IEC
SCHNEIDER IECMagContactor; NonReversing; 240VAC
IEC Magnetic Contactor; Auxiliary Contact Form 1NO; NEMA Enclosure Rating No Enclosure; NEMA Size Not Applicable; Coil Voltage 240V AC; Number of Poles 3; Full Load Current - Inductive 12 A; Full Load Current - Resistive 12 A; Reversing Capability Non-Reversing; Overall Height 3.03 in; Overall Width 1.77 in; Terminal Connection Type Screw Clamp Terminals; Mounting Style DIN Rail; Plate; Series TeSys Easy; Number of Auxillary Contacts 1; Contactor Style IEC
SCHNEIDER ManualMotorStarter;IEC;PushButton;Therm
Manual Motor Starter; NEMA Size Not Applicable; Horsepower @ Single Phase - 240V AC 1/6 hp; Maximum Voltage Rating 690V AC; Number of Poles 3; Operator Push Button; Phase Three; Current AC 2.5 A; Horsepower @ Three Phase - 208V AC 1/2 hp; Horsepower @ Three Phase - 240V AC 1/2 hp; Horsepower @ Three Phase - 480V AC 1 hp; Series TeSys Easy; Horsepower @ Three Phase - 600V AC 1 1/2 hp; Maximum Overload Relay Current Setting 2.5 A; Minimum Overload Relay Current Setting 1.6 A
SCHNEIDER Force;DIN Rail;4.72" D;3.94" H;1.77"W;3W
Force; Maximum Operating Temperature 185 Degrees F; Minimum Operating Temperature -13 Degrees F
SCHNEIDER IECMagneticContactor;NonReversing;24VDC
IEC Magnetic Contactor; Auxiliary Contact Form 1NO; NEMA Enclosure Rating No Enclosure; NEMA Size Not Applicable; Coil Voltage 24V DC; Number of Poles 3; Full Load Current - Inductive 12 A; Full Load Current - Resistive 12 A; Reversing Capability Non-Reversing; Overall Height 3.03 in; Overall Width 1.77 in; Terminal Connection Type Screw Clamp Terminals; Mounting Style DIN Rail; Plate; Series TeSys Easy; Number of Auxillary Contacts 1; Contactor Style IEC; Horsepower @ Three Phase - 240V AC 2 hp
SCHNEIDER ManualMotorStarter;IEC;PushButton;Therm
Manual Motor Starter; NEMA Size Not Applicable; Horsepower @ Single Phase - 240V AC 1/10 hp; Maximum Voltage Rating 690V AC; Number of Poles 3; Operator Push Button; Phase Three; Current AC 1.6 A; Horsepower @ Three Phase - 480V AC 3/4 hp; Series TeSys Easy; Horsepower @ Three Phase - 600V AC 3/4 hp; Maximum Overload Relay Current Setting 1.6 A; Minimum Overload Relay Current Setting 1 A; Mounting Style DIN Rail; NEMA Enclosure Rating No Enclosure; Number of Required Thermals Not Applicable
SCHNEIDER Force;DIN Rail;4.72" D;3.94" H;0.89"W;2W
Force; Delay Time 0.5 sec; 2 sec; 4 sec; Delay Type Adjustable; Electrical Connection Screw Terminal; Terminal Block Removable; IP Rating IP20; IP40; IP54; Input Voltage 24V AC/DC; Mounting Style DIN Rail; Number of Inputs 2; Standards CCC; cULus Listed; EAC; IEC 60947-5-1; IEC 61508-1/2/3; IEC 62061; ISO 13849-1; TUV Certified; Contact Rating (AC) 1 A @ 15V (NC); 3 A @ 1V (NC); 3 A @ 15V (NO); 5 A @ 1V (NO); Contact Rating (DC) 1 A @ 13V (NC); 3 A @ 1V (NC); 3 A @ 13V (NO); 5 A @ 1V (NO)
SCHNEIDER OverloadRelay; IEC; Thermal; Auto/Manual
IEC Overload Relay; Auxiliary Contact Form 1NO/1NC; Maximum Overload Relay Current Setting 6 A; Minimum Overload Relay Current Setting 4 A; Trip Class 10; Maximum Voltage Rating 690V AC; NEMA Size Not Applicable; Number of Poles 3; Reset Type Auto; Manual; Mounting Style Separately Mounted; Terminal Connection Type Screw Clamp Terminals; Compatible with Series Easy TeSys; Relay Style IEC; Overload Protection Type Thermal; Phase Three
SCHNEIDER Auxiliary Contact Block; 1NO/1NC; 2.5 A
Auxiliary Contact Block; Current AC 2.5 A; Number of Contacts 2; Mounting Front; Number of Normally Open Contacts 1; Maximum Voltage Rating 240V AC; 60V DC; Number of Normally Closed Contacts 1; Terminal Connection Type Screw Clamp Terminals; Compatible with Series Easy TeSys; TeSys
SCHNEIDER OverloadRelay; IEC; Thermal; Auto/Manual
IEC Overload Relay; Auxiliary Contact Form 1NO/1NC; Maximum Overload Relay Current Setting 18 A; Minimum Overload Relay Current Setting 12 A; Trip Class 10; Maximum Voltage Rating 690V AC; NEMA Size Not Applicable; Number of Poles 3; Reset Type Auto; Manual; Mounting Style Separately Mounted; Terminal Connection Type Screw Clamp Terminals; Compatible with Series Easy TeSys; Relay Style IEC; Overload Protection Type Thermal; Phase Three
SCHNEIDER Safety Relay Extension;48 to 240 VAC/VDC
Force; Delay Time None; Delay Type Fixed; Electrical Connection Screw Terminal; Terminal Block Removable; IP Rating IP20; IP40; IP54; Input Voltage 48 to 240V AC/DC; Mounting Style DIN Rail; Number of Inputs 2; Number of Pins 16; Output Switch Configuration (3) NO; Response Time 20 msec; Standards CCC; cULus Listed; EAC; IEC 60947-5-1; IEC 61508-1/2/3; IEC 62061; ISO 13849-1; TUV Certified; Contact Rating (AC) 8 A @ 250V