Filters
Clamp On Earth Resistance Tester; Jaw Capacity 1.3 in (35mm); Leakage Current Range 0.2 mA to 40 A; Number of Records Stored 300; Resistance Accuracy High Range +/-25 Percent; Low Range +/-1.5 Percent; Communication Protocol Bluetooth; Includes (4) AA Batteries; Hard Carrying Case
Kelvin Probe Set, CAT Safety Rating Not Rated, Cable/Lead Color Black, Red, For Use With Microohmmeters, Test Lead Length 10 ft, Product Type Kelvin Probe, Compatible with Grainger Part Number - New 4YY53, Compatible with Manufacturer Model Number - New AEMC 6250
Phase Sequence and Motor Rotation; CAT Safety Rating CAT III 1000V; CAT IV 600V; Display Screen Type LCD; Display Type Digital; For Voltage Range 40 to 850 VAC (15 to 400Hz); Includes (3) 4 ft Color-Coded Test Leads (Red/Black/Blue); (3) Alligator Clips; Carrying Case; Maximum Frequency 400 Hz; Minimum Frequency 15 Hz; Testing Functions Phase Rotation; Phase Voltage Presence; Alert Type Digital Display; Battery Chemistry Not Applicable; Battery Size Not Applicable
Power/Energy Logger; Calibration Certificate None; Current Channels 3; For Phase Three; Includes (12) Color Coded ID Markers; (3) MiniFlex(R) MA193-10-BK Sensors; (4) Black Test Leads with Alligator Clips; Carrying Bag; USB SD Card Adapter; Maximum AC Current Measured 6;500 A; Peak Capture No; Power Factor 0 to 1; Voltage Channels 3; Calibration Frequency 42.5 to 69 to 400 Hz; Communication Protocol Bluetooth; SD Card; USB; Crest Factor I=6.5; V=6.5
Earth Ground Tester; CAT Safety Rating CAT III; Calibration Certificate NIST; Display Type Digital; IP Rating IP63; IP65; Maximum Ground Resistance Measurement 2;000 ohm; Minimum Ground Resistance Measurement 0 ohm; Test Current 0.1 mA to 10 mA; Waterproof Not Applicable; Standards EN 61010-1; EN 61326-1; EN 61557; Pollution Degree 2; Battery Chemistry Alkaline; Battery Size C; Display Screen Type LCD; Includes (8) Batteries
Micro Ohmmeter; Communication Protocol USB; Insulation Resistance Resolution 1 microohm; Maximum Insulation Resistance 50 microohm; Minimum Insulation Resistance 2 microohm; Number of Digits 2; Power Source Battery; Includes (2) 10 ft Cables with 10 A Kelvin Clips; and User Manual; Battery; Power Cord; Software; USB Interface Cable
Clamp On Earth Tester; Ground Resistance Range 0.025 to 1500 ohm; Jaw Capacity 1.3 In. (35mm); Resolution 0.001 ohm; Operating Frequency 50; 60 128; 2083 Hz; Current Measurement Range 0.2mA to 40A; Display OLED; Counts 10;000; Resistance Accuracy Low Range +/- 1.5 Percent; High Range +/- 25 Percent; Auto Power Off Yes; Interface Bluetooth(R); Battery Type (2) 1.5V AA; Safety Rating ETL; CAT IV 600V; Special Features Stores 2000 Measurements
Clamp On Earth Tester; Ground Resistance Range 0.025 to 1500 ohm; Jaw Capacity 1.3 In. (35mm); Resolution 0.001 ohm; Operating Frequency 50; 60 128; 2083 Hz; Current Measurement Range 0.2mA to 40A; Display OLED; Counts 10;000; Resistance Accuracy Low Range +/- 1.5 Percent; High Range +/- 25 Percent; Auto Power Off Yes; Battery Type (2) 1.5V AA; Safety Rating ETL; CAT IV 600V; Special Features Stores 300 Measurements; Includes Hard Carrying Case; (4) AA Batteries
Clamp On AC Current Logger; Current Range 0 to 600 A AC; 1 Current Channels; Current Accuracy +/-1 Percent of Reading to 400A; +/-3 Percent of Reading to 600A; True RMS Yes; Single Phase; Power Source (2) AA Batteries; 1 Minute To Greater Than 8 Weeks; User Programmable Recording Capacity; Neutral Current Logging Up to 600 AC A; Current Harmonics Logging Up To The 50th; Sampling Rate -; Interface USB
Voltage Data Logger; AC Voltage Accuracy +/-0.5 Percent; Alert Type Light; Current Channels Not Applicable; For Phase Single; Maximum AC Current Measurement Not Applicable; Maximum AC Voltage Measured 600 V AC; Minimum Operating Temperature Degrees F 14 Degrees F; Maximum Operating Temperature Degrees F 122 Degrees F; Minimum AC Current Measurement Not Applicable; Maximum Sampling Rate 64 sec; Minimum AC Voltage Measured 5 V AC; Number of Records Stored 240;000