Close
Noble
Free Shipping on orders over $100 - CONUS ONLY
Home
Filters
Apply Filters

NARROW DOWN


COUNTRY_OF_ORIGIN
-

Canada

China

India

Italy

Japan

Mexico

United States


PROP_65_INDICATOR
-

Y


CONTRACT
-

47QSCCD0007

47QSEA19D00AY


BRAND
-
BELL & GOSSETT Impeller;In-Line;Bronze;4 27/32" OD
Impeller; Compatible with Brand Bell and Gossett; Compatible with Manufacturer Model Number 60-602S; 60-602T; 60-605S; 60-605T; 60-B602S; 60-B602T; 60-B605S; 60-B605T; Compatible with Series 60; Compatible with Series Family 60; Impeller Material Bronze; Overall Diameter 5.75 in; Compatible with Pump Type In-Line Circulating Pumps; Manufacturers Warranty Length 1 yr
BELL & GOSSETT Bp400-30 Heat Exchanger
Bp400-30 Heat Exchanger
BELL & GOSSETT Steam Trap;25 psi;Brass;3/4 in;2 Ports
Steam Trap; Application Convectors; Steam Kettles; Evaporators; Heating Coils; Radiators; Sterilizers; Steam Tracing; Unit Heaters; Body Material Brass; Condensate Capacity 162 lb/hr; Configuration Angle; Distance Between Inlet and Outlet Port 3 1/8 in; Includes Air Vent Air Vent Included; Inlet Port Connection Gender Female; Inlet Port Connection Size 3/4 in; Inlet Port Connection Type NPT; Installation Orientation Horizontal; Manufacturer Series 17C; Number of Ports 2
BELL & GOSSETT Heat Exch;Braze Plate;900;000 BtuH
Heat Exchanger; Heat Exchanger Type Braze Plate; Heat Dissipation Capacity for Water 900;000 BtuH; Heat Dissipation Capacity for Oil 110;000 BtuH; Total Surface Area 13.54 sq ft; Overall Height 12 1/4 in; Overall Width 4 3/8 in; Overall Depth 5 1/2 in; Maximum Pressure Rating 435 psig; Maximum Operating Temperature 450 Degrees F; Minimum Operating Temperature -190 Degrees F; Flow Capacity 50 gpm; Pipe Connection Size 1 in; Channel Plate Material Stainless Steel
BELL & GOSSETT Hydronic Circulating Pump;Flanged;1/6HP
Hydronic Circulating Pump; Compatible Intake Pipe Size 3/4 in; 1 in; 1 1/4 in; 1 1/2 in; Connection Type Flange; Face to Face Dimension 8 1/2 in; Flange or Union Included No; For Use With Potable Systems Yes; Horsepower 1/6; Maximum Feet of Head 18 ft; Maximum Flow Rate @ 10 Feet of Head 22 gpm; Maximum Flow Rate @ 15 Feet of Head 13 gpm; Maximum Flow Rate @ 1 Foot of Head 29 gpm; Nameplate Voltage 115V AC; Number of Speeds 1; Phase Single; Pump Type 3-Piece; Series Family Series PR
BELL & GOSSETT Submersible Sump Pump
Submersible Sump Pump
BELL & GOSSETT Potable Water Circulating Pump
Potable Water Circulating Pump; Compatible Intake Pipe Size 3 in; For Use With Potable Systems Yes; Horsepower 5; Maximum Feet of Head 71 ft; Nameplate Voltage 208 to 240/460V AC; Phase Three; Series Family E90; Series BE9037T; Amps 6.5 to 13.0/13.7; Compatible Discharge Pipe Size 3 in; Compatible Media Type Water
BELL & GOSSETT Inboard Ball Bearing
Inboard Ball Bearing
BELL & GOSSETT Float/Therm Steam Trap Cover Gasket
Steam Trap Cover Gasket; Compatible Brand Bell & Gossett; Compatible Grainger Part Number 2CMD2; 2CMD5; 2CMD6; 2CMD7; 4NU59; 4NU60; 4NU64; 4NU69; 4NU70; Compatible Manufacturer Model Number FT015C-10; FT015C-6; FT015C-8; FT015H-3; FT015H-4; FT015H-5; FT015H-6; FT015H-8; FT015X-8; Compatible Series FT015; Compatible Steam Trap Type Float; Product Type Steam Trap Cover Gasket
BELL & GOSSETT O Ring
O Ring
BELL & GOSSETT Brazed Plate Heat Exchanger;BP400-20
Heat Exchanger; Heat Exchanger Type Braze Plate; Overall Height 8 1/4 in; Overall Width 3 1/8 in; Overall Depth 3 in; Maximum Pressure Rating 435 psig; Maximum Operating Temperature 450 Degrees F; Minimum Operating Temperature -310 Degrees F; Flow Capacity 52 gpm; Pipe Connection Size Not Applicable; Channel Plate Material Stainless Steel; Brazing Material Copper; Pipe Connection Gender Not Applicable; Pipe Connection Type Not Applicable; Cover Plate Material Stainless Steel
BELL & GOSSETT Pump Shaft Sleeve
Pump Shaft Sleeve
BELL & GOSSETT Bearing Assembly; For 189162LF
Bearing Assembly; Compatible with Brand Bell and Gossett; Compatible with Series HD; HV; Series 100; Compatible with Series Family HD; HV; Series 100; Compatible with Pump Type In-Line Circulating Pumps
BELL & GOSSETT Flange;Chrome Plated Steel;3/4 NPT
Flange; Compatible Pipe Size 3/4 in; Compatible with Brand Bell and Gossett; Compatible with Series 100B; Ecocirc XLB; NBF-12F/LW; NBF-22; NBF-33; NBF-36; PL-100; PL-30B; PL-36B; PRAB; Flange to Pipe Connection Type FNPT; For Use With Potable Systems Yes; Flange Type Standard; Number of Mounting Holes 2; Valve Type Not Applicable; Flange Material Stainless Steel
BELL & GOSSETT Hydronic Circulating Pump;Flanged;1/12HP
Hydronic Circulating Pump; Compatible Intake Pipe Size 3/4 in; 1 in; 1 1/4 in; 1 1/2 in; Connection Type Flange; Face to Face Dimension 6 3/8 in; Flange or Union Included No; For Use With Potable Systems Yes; Horsepower 1/12; Maximum Feet of Head 25 ft; Maximum Flow Rate @ 10 Feet of Head 20 gpm; Maximum Flow Rate @ 15 Feet of Head 15 gpm; Maximum Flow Rate @ 1 Foot of Head 30 gpm; Nameplate Voltage 115V AC; Number of Speeds 1; Phase Single; Pump Type Standard; Series Family PL
BELL & GOSSETT Hft-30 Diaphragm Expan Tank
Hft-30 Diaphragm Expan Tank
BELL & GOSSETT Pump Motor;3/4 hp;3 phase
Circulating Pump Motor; Compatible with Brand Bell and Gossett; Compatible with Pump Type In-Line Circulating Pumps; Compatible with Series Family BE609T; BE611S; BE611T; BE615S; BE615T; BE626S; BE626T; E609S; E609TBE609S; E611S; E611T; E613S; E613T; E615S; E615T; E622S; E622T; E626S; E626T; Horsepower 3/4; Maximum RPM 1;725 RPM; Minimum Ambient Temperature 40 Degrees F; Motor Enclosure Design Open Dripproof; Motor Thermal Protection None; Nameplate Voltage 230/460V AC; Number of Speeds 1
BELL & GOSSETT Heat Exch;Braze Plate;1;100;000 BtuH
Heat Exchanger; Heat Exchanger Type Braze Plate; Heat Dissipation Capacity for Water 1;100;000 BtuH; Heat Dissipation Capacity for Oil 190;875 BtuH; Total Surface Area 29.76 sq ft; Overall Height 24 1/4 in; Overall Width 7 1/2 in; Overall Depth 3 7/8 in; Maximum Pressure Rating 435 psig; Maximum Operating Temperature 450 Degrees F; Minimum Operating Temperature -310 Degrees F; Flow Capacity 225 gpm; Pipe Connection Size 2 in; Channel Plate Material Stainless Steel
BELL & GOSSETT Ser 1510 Shaft Sleeve
Ser 1510 Shaft Sleeve
BELL & GOSSETT Gasket;for Triple Duty Valve
Gasket;for Triple Duty Valve
BELL & GOSSETT Steam Trap;Cast Iron;30 psi;3/4 in
Steam Trap; Application Process Equipment; Body Material Cast Iron; Condensate Capacity 1;900 lb/hr; Configuration H Pattern; Distance Between Inlet and Outlet Port 5 1/2 in; Float Material Cast Iron; Includes Air Vent Air Vent Included; Includes Strainer Strainer Included; Installation Orientation Horizontal; Manufacturer Series H; Maximum Capacity at Maximum Pressure Load 1;900 lb/hr at 30 psi; Number of Ports 4; Operating Pressure - Maximum 30 psi
BELL & GOSSETT Motor Bracket
Motor Bracket
BELL & GOSSETT Bearing;Inbound Side
Bearing;Inbound Side
BELL & GOSSETT Overload Protector-Relay
Overload Protector-Relay
BELL & GOSSETT Packing Nut;w/O Set Screw
Packing Nut;w/O Set Screw
BELL & GOSSETT Valve 3Dv-1 1/4Rff 1.25"Tripledutyvl
Valve 3Dv-1 1/4Rff 1.25 In.Tripledutyvl
BELL & GOSSETT Flange;Chrome Plated Steel;3/4 NPT;PK2
Flange; Compatible Pipe Size 3/4 in; Compatible with Brand Bell and Gossett; Compatible with Grainger Part Number 5JPA6; 5JPA7; 5JPA9; 5JPC0; 5JPC1; 5JPC2; 5JPC3; 5JPD3; 5JPD9; 788NP4; 788NP5; 788NT7; Compatible with Series 100B; Ecocirc XLB; NBF-12F/LW; NBF-22; NBF-33; NBF-36; PL-100; PL-30B; PL-36B; PRAB; Flange to Pipe Connection Type FNPT; For Use With Potable Systems Yes; Flange Type Standard; Number of Mounting Holes 2; Valve Type Not Applicable
BELL & GOSSETT Hydronic Circulating Pump;FNPT;1HP
Hydronic Circulating Pump; Compatible Intake Pipe Size 1 1/2 in; Connection Type FNPT; Face to Face Dimension 13 1/2 in; Flange or Union Included Not Applicable; For Use With Potable Systems No; Horsepower 1; Maximum Feet of Head 41 ft; Maximum Flow Rate @ 15 Feet of Head 125 gpm; Nameplate Voltage 115/208-230V AC; Number of Speeds 1; Phase Single; Pump Type 3-Piece; Series Family E-60; Maximum Flow Rate @ 20 Feet of Head 110 gpm; Maximum Flow Rate @ 25 Feet of Head 100 gpm
BELL & GOSSETT Hydronic Circulating Pump;Flanged;1HP
Hydronic Circulating Pump; Compatible Intake Pipe Size 2 in; Connection Type Flange; Face to Face Dimension 14 in; Flange or Union Included Yes; For Use With Potable Systems Yes; Horsepower 1; Maximum Feet of Head 32 ft; Maximum Flow Rate @ 15 Feet of Head 130 gpm; Nameplate Voltage 208-230/460V AC; Number of Speeds 1; Phase Three; Pump Type 3-Piece; Series Family E-60; Maximum Flow Rate @ 20 Feet of Head 110 gpm; Maximum Flow Rate @ 25 Feet of Head 90 gpm
BELL & GOSSETT Air Separator;Brass;250F;150 psi;Water
Air Separator; Air Vent Connection Gender Female; Air Vent Connection Size Not Applicable; Air Vent Connection Type Not Applicable; Application Air Removers; Body Material Brass; Cap Material Brass; Configuration In-line; Distance Between Inlet and Outlet Port 1 13/16 in; Expansion Tank Connection Size 1/2 in; Expansion Tank Connection Type NPT; For Media Water; Inlet Port Connection Gender Female; Inlet Port Connection Size 3/4 in; Inlet Port Connection Type NPT