Filters
Master Controller, 10 Channels, Product Type Dust Collector Timer Controller, Overall Length 8 3/4 in, Overall Width 2 3/4 in
Clip Pipe Mount Dial Thermometer, 20 Degrees to 260 Degrees C, Clip, For Pipe Diameter 1 5/8 in to 2 3/8 in, Dial Diameter 2 in, Steel Housing with Glass Lens, Celsius
Digital Process Pressure Gauge, Accuracy +/-0.50 Percent, Gauge Case Material ABS, Nominal Dial Size 3 in, IP/NEMA Rating Not Rated, Hazardous Location Rating Not Rated, Compatible Process Media Liquids and Compatible Gases, Sensor Material Silicone, Socket Material Stainless Steel, Process Connection Type NPT, Display Units bar, in Hg, kg/sq cm, kPa, psi, Process Connection Gender Male, Battery Type 9V Battery, Process Connection Location Bottom, Process Connection Size 1/4 in
Clip On Dial Thermometer, -40 Degrees to 160 Degrees F, NSF Rated No, Stem Length 8 in, Includes NIST-Traceable Certificate No, Glow-in-the-Dark No, Dial Diameter 2 in, Long Reach No, Clip-On, Fahrenheit
Submersible Level Transmitter, Output 4 to 20mA DC, Tip Design Bullet Nose, Minimum Pressure 0 m wc, Maximum Pressure 30 m wc, Accuracy +/-0.25 Percent of Full Scale, Cable Length 36 m, Cable Coating Polyurethane, Sensor Length 6.7 in, Electrical Protection Yes, Power Required 10 to 33V DC, Series MBLT, Cable Material Polyurethane, Electrical Connections Cable & Wire Leads, Housing Material 316 Stainless Steel, Manufacturers Warranty Length 1 yr, Maximum Loop Resistance 1000 Ohm
Digital Process Pressure Gauge; Accuracy +/-0.50 Percent; Gauge Case Material ABS; Nominal Dial Size 3 in; IP/NEMA Rating Not Rated; Hazardous Location Rating Not Rated; Compatible Process Media Liquids and Compatible Gases; Sensor Material Silicone; Socket Material Stainless Steel; Process Connection Type NPT; Display Units bar; in Hg; kg/sq cm; kPa; mbar; mm Hg; oz/sq in; psi; Process Connection Gender Male; Battery Type 9V Battery; Process Connection Location Bottom
Thread-Mounted Digital Thermometer, -58 Degrees to 302 Degrees F/-50 Degrees to 150 Degrees C, Stem Length 18 in, 1/2 in NPT, Adjustable-Angle, Includes NIST-Traceable Certificate No, 3 in dia Display with 3 1/2-Digit LCD - 1/2 in Digit Height, 300 Stainless Steel Housing with Acrylic Lens and Stainless Steel Stem, 3V Solar Cell (Minimum 35 lux), Digital, Solar-Powered Digital Thermometer
Temperature Controller, Digital, Thermocouple Sensor Type, DIN Size 1/4, Input Voltage 100 to 240V AC, Switch Function 2.5 A @ 240V AC Resistive, Output SSR, Temp. Range 14 Degrees to 131 Degrees F, Control Mode PID, PI, 0 to 20mA Amps, Length 95.9 mm, Width 95.9 mm, Depth 115.8 mm, Outputs Include Solid State Relay, Mechanical Relay, Programmable Alarm can Act as High or Low or High/Low Guard Band Alarm, Power Consumption 5 VA, Standards CE, cULus, Series 2500
Clip On Dial Thermometer, 50 Degrees to 300 Degrees F, NSF Rated No, Stem Length 8 in, Includes NIST-Traceable Certificate No, Glow-in-the-Dark No, Dial Diameter 1 3/4 in, Long Reach No, Clip-On, Fahrenheit
Submersible Level Transmitter, Output 4 to 20mA DC, Tip Design Bullet Nose, Minimum Pressure 0 m wc, Maximum Pressure 100 m wc, Accuracy +/-0.25 Percent of Full Scale, Cable Length 106 m, Cable Coating Polyurethane, Sensor Length 6.7 in, Electrical Protection Yes, Power Required 10 to 33V DC, Series MBLT, Cable Material Polyurethane, Electrical Connections Cable & Wire Leads, Housing Material 316 Stainless Steel, Manufacturers Warranty Length 1 yr, Maximum Loop Resistance 1000 Ohm
Analog Manometer; Pressure Range -4 to 4 in wc; For Tubing Diameter 0.187 in; Maximum Operating Pressure 100 psi; Maximum Pressure 4 in wc; Minimum Pressure -4 in wc; Scale Units in wc; Series 1223; Manometer Type Flexible U-Tube; Housing Material Plastic; Includes Gas Pressure Kit No; Fluid Color Red; Includes 1 oz Red Gage Fluid; Magnetic Mounting Clips; Plastic Tubing; Tube Adapters; Tube Clamp and Nylon Tubing Connections; Lens Material Butyrate; Minor Graduations 0.1 in wc
Humidity Transmitters; Output 4 to 20mA; Temperature Accuracy +/-0.54 Degrees F @ 32 Degrees F; Maximum Sensed Temperature 140 Degrees F; Minimum Sensed Temperature -40 Degrees F; Relative Humidity Range 0 to 100 Percent; Relative Humidity Accuracy +/-2 Percent 10 to 90 Percent RH at 25 Degrees C; Probe Length 3 in; Electrical Connections Screw Terminals; IP Rating IP66; NEMA Rating NEMA 4X; Series RHP; Compensated Temperature Range -4 Degrees to 140 Degrees F
Window Sight Flow Indicator with Impeller, Indicator Type Rotor, Body Material 316 Stainless Steel, Connection Size 3/4 in, Connection Type FNPT, Operating Pressure - Maximum 125 psig, Sight Material Tempered Glass, Sight Diameter 2 in, Number of Windows 2, Flow Direction Horizontal Left, Horizontal Right, Vertical Down, Vertical Up, Media Temperature - Minimum 32 Degrees F, Media Temperature -Maximum 200 Degrees F, Seal Material Buna-N
Digital Process Pressure Gauge, Accuracy +/-0.50 Percent, Gauge Case Material ABS, Nominal Dial Size 3 in, IP/NEMA Rating Not Rated, Hazardous Location Rating Not Rated, Compatible Process Media Air and Compatible Gases, Sensor Material Silicone, Socket Material Stainless Steel, Process Connection Type NPT, Display Units bar, in Hg, kg/sq cm, kPa, psi, Process Connection Gender Male, Battery Type 9V Battery, Process Connection Location Bottom, Process Connection Size 1/4 in, Power Source Battery
Differential Pressure Gauge, Pressure Range 0-6.0 Inches WC, Pressure Range Minor Divisions 0.20, Rated Total Pressure -20 Inches Hg to 15 PSIG, Differential Pressure
Flow Meter, Accuracy 2 Percent Full Scale, Not Applicable Interface
Carbon Dioxide/RH/Temperature Transmitter, For Use With Building Management Controllers, Gas Detected Carbon Dioxide, Standards CE Compliant, RoHS Compliant, Product Type Detector Transmitter, Mounting Location Duct, Sensor Type Infrared, Display Type None, Detection Concentration - Minimum 0 ppm, Detection Concentration - Maximum 2,000 ppm, Response Time 2 min, Measures Temperature Temperature Measuring, Operating Temperature - Minimum 32 Degrees F, Operating Temperature - Maximum 122 Degrees F
Averaging Flow Sensor, Insertion Length 3 1/8 in, Maximum Media Temperature 120 Degrees F, Connection Size 1/4 in, 3/8 in, Connection Type Push-On, Series PAFS-1000, Wetted Materials ABS/Polycarbonate, Center to Center Distance 2.75 in, Flange Length 3.5 in, Flange Width 1.25 in, For Media Air, Compatible Gases, Includes Integral Mounting Flange with Gasket, K Factor 1.32, Maximum Operating Temperature 120 Degrees F, Minimum Media Temperature 40 Degrees F
Clip On Dial Thermometer, 50 Degrees to 330 Degrees F, NSF Rated No, Stem Length 5 in, Includes NIST-Traceable Certificate No, Glow-in-the-Dark No, Dial Diameter 1 3/4 in, Long Reach No, Clip-On, Fahrenheit
Digital Industrial Pressure Gauge, Accuracy +/-1.00 Percent, Gauge Case Material ABS, Nominal Dial Size 2 1/2 in, IP/NEMA Rating Not Rated, Hazardous Location Rating Not Rated, Compatible Process Media Air and Compatible Gases, Sensor Material Silicone, Socket Material 316L Stainless Steel, Process Connection Type NPT, Display Units bar, cm wc, ft wc, in Hg, in wc, kg/sq cm, kPa, mbar, mm Hg, oz/sq in, psig, Process Connection Gender Male, Battery Type 9V Battery
Air Manometer Kit, Maximum Pressure 20 in wc, Minimum Pressure 0 in wc, Pressure Accuracy +/-0.5 Percent of Full Scale, Process Connection Size 1/8 in, 3/16 in, Process Connection Type Hose Barb, Digital Display Features 4 Digit LED, Series 475, Includes Batteries Yes
Digital Industrial Pressure Gauge, Accuracy +/-1.00 Percent, Gauge Case Material ABS, Nominal Dial Size 3 in, IP/NEMA Rating Not Rated, Hazardous Location Rating Not Rated, Compatible Process Media Air and Compatible Gases, Sensor Material Silicone, Socket Material 316L Stainless Steel, Process Connection Type NPT, Display Units bar, cm wc, ft wc, in Hg, in wc, kg/sq cm, kPa, mbar, mm Hg, oz/sq in, psig, Process Connection Gender Male, Battery Type 9V Alkaline Battery
Calibration Adapter; Product Type Calibration Adapter; For Gas Type Carbon Monoxide/Nitrogen Dioxide; For Use With CMS300 Series Carbon Monoxide Transmitter and Switch; GSTA and GSTC Series Carbon Monoxide Gas Transmitter/Nitrogen Dioxide Gas Transmitter
Digital Vacuum Gauge with Transmitter; Nominal Dial Size 3 in; Wetted Materials 316L Stainless Steel; Accuracy +/-0.25 Percent of Full Scale; Minimum Pressure 0 psi; Maximum Pressure 30 psi; Display Units bar; cm wc; ft wc; in Hg; in wc; kg/cm2; kPa; mbar; mm Hg; oz/in²; psig; Output 4 to 20mA DC; Series DPG-200; Gauge Primary Range Units psi; Gauge Process Connection Gender Male; IP Rating IP66; NEMA Rating NEMA 4X; Gauge Process Connection Location Bottom; Gauge Process Connection Size 1/4 in
Temperature Controller, Digital, RTD, Thermocouple Sensor Type, DIN Size 1/16, Input Voltage 100 to 240V AC, Switch Function 0 to 20 mA, Output Current, Temp. Range 14 Degrees to 131 Degrees F, Control Mode Fuzzy Logic, On/Off Action, P, PI or PID Manual Tune, PID, Universal Input, 20mA Amps, Length 48 mm, Width 48 mm, Depth 144.4 mm, Four Security Levels are Password Protected, Front Panel is Waterproof and Corrosion Resistant, Two 4-Digit LED Displays, Alarms Relay, 3A, SPST
Extendable Pole for SAH-22, Product Type Extendable Pole, Compatible with Manufacturer Model Number SAH, Overall Height 12 ft
Air Velocity Transmitter, Digital Display Screen Type LED, Response Time 1.5 sec, Maximum Operating Temperature 140 Degrees F, Probe Diameter 0.5 in, Maximum Output Signal 20 mA, Maximum Temperature Measured 212 Degrees F, Maximum Velocity Measured 15,000 fpm, Minimum Operating Temperature 32 Degrees F, Minimum Temperature Measured -40 Degrees F, Minimum Velocity Measured 250 fpm, Minimum Output Signal 4 mA, Pressure Limit 100 psi, Air Velocity Accuracy +/-3 Percent (32 to 122 Degrees F)
Temperature Controller, Digital, RTD, Thermocouple Sensor Type, DIN Size 1/8, Input Voltage 100 to 240V AC, Switch Function SPST, 5 A @ 250V AC Resistive, Output (2) Relay, Temp. Range 32 Degrees to 122 Degrees F, Control Mode Fuzzy Logic, Manual, On/Off Action, PID, 5A Amps, Length 148.03 mm, Width 72.78 mm, Depth 127.61 mm
Carbon Dioxide Sensor, Gas Detected Carbon Dioxide, Standards BTL Listed, CE Compliant, Product Type Fixed Gas Detector, Mounting Location Wall, Sensor Type Infrared, Display Type None, Detection Concentration - Minimum 0 ppm, Detection Concentration - Maximum 2,000 ppm, Measures Temperature Temperature Measuring, Includes Temperature Set Point Temperature Set Point Included, Operating Temperature - Minimum 32 Degrees F, Operating Temperature - Maximum 122 Degrees F, Number of Gases Detected 1