Close
Noble
Free Shipping on orders over $100 - CONUS ONLY
Filters
Apply Filters

NARROW DOWN


COUNTRY OF ORIGIN
-

-

China

Czech Republic

Mexico

United States


PROPOSITION 65 WARNING
-

Y


UNIT OF MEASURE QTY
-

EA


CONTRACT ID
-

47QSCCD0007


BRAND
-

SQUARE D Panelboard Enclosure/Box Type 1 73H 32W
Panelboard Enclosure/Box Type 1 73H 32W
SQUARE D Switch Fusible Qmb 600V 60A 3P Twin
Switch Fusible Qmb 600V 60A 3P Twin
SQUARE D Compression Lug Kit,125A
Compression Lug Kit, Amps 125 A, Mounting Location Breaker, Number of Lugs Included 2, Number of Poles 2, Includes (2) Compression Lug, For Use With Powerpact(R) B Circuit Breakers
SQUARE D Circuit Breaker,10A,120/240V,3P
Miniature Circuit Breaker, Amps 10 A, AC Voltage Rating 120/240V AC, Circuit Breaker Type Standard, Number of Poles 3, DC Voltage Rating 48V DC, Circuit Breaker Actuator Toggle, Circuit Breaker Mounting Style Surface/DIN Rail, Compatible Panelboard/Load Center Series QO, Phase Three, Series QOU, Max. AIR Rating 10kA at 120/240V AC, For Use With Air Conditioning and Refrigeration Equipment, Heating, Terminal Connection Slotted Box Lug (Reversible Line and Load), Frame Size 100A/QOU
SQUARE D Pnlbd Cover/Trim Iline T1 S 42W86H Hr
Pnlbd Cover/Trim Iline T1 S 42W86H Hr
SQUARE D Circuit Breaker,30A,Plug In,120V,3P
Miniature Circuit Breaker, Amps 30 A, AC Voltage Rating 120V AC, Circuit Breaker Type Ground Fault Circuit Interrupter (Class A - 5mA), Number of Poles 3, DC Voltage Rating Not Rated, Circuit Breaker Actuator Toggle, Circuit Breaker Mounting Style Plug In, Compatible Panelboard/Load Center Series NQ, QO, Phase Three, Series QO, Max. AIR Rating 10kA at 120V AC, For Use With QO Load Centers and NQ Panelboards, Terminal Connection Pressure Plate, Frame Size 100A/QO, Length 4.12 in, Width 2.25 in
SQUARE D Circuit Breaker,25A,Bolt On,120V,1P
Miniature Circuit Breaker, Amps 25 A, AC Voltage Rating 120V AC, Circuit Breaker Type Ground Fault Circuit Interrupter, Number of Poles 1, DC Voltage Rating Not Rated, Circuit Breaker Actuator Paddle, Circuit Breaker Mounting Style Bolt On, Compatible Panelboard/Load Center Series NQ, QO, Phase Single, Series QOB, Max. AIR Rating 10kA at 120V AC, For Use With QO Load Centers and NQ Panelboards, Terminal Connection Pressure Plate, Frame Size 100A/QO, Length 4.12 in, Width 0.75 in, Depth 2.91 in
SQUARE D Thermal Unit, TripClass 20, MeltingAlloy
Thermal Unit, Trip Class 20, Overload Protection Type Melting Alloy, Full Load Current 35.5 to 38.2 A, 38.4 to 39.9 A, NEMA Size 2, Frame Size B, S, Compatible with Grainger Part Number 48P834, 4DF22, 4DF23, Compatible with Manufacturer Model Number 8911DPSG53V06, 8911DPSG53V09, 9065SEO8
SQUARE D Handle
Handle
SQUARE D PowerPact J-Frame breaker,I-Line,therm
PowerPact J-Frame breaker,I-Line,therm
SQUARE D IECMagContactor, NonReversing, 240VAC
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 240V AC, Number of Poles 3, Full Load Current - Inductive 150 A, Full Load Current - Resistive 200 A, Reversing Capability Non-Reversing, Overall Height 6.22 in, Overall Width 0.47 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
SQUARE D Handle
Handle
SQUARE D Surge mod IMA-120kA-480Y/277VAC-3P
Surge mod IMA - 120kA - 480Y/277VAC - 3P
SQUARE D Cover Frame,X Series,5 Gangs,Screwles
Cover Frame,X Series,5 Gangs,Screwles
SQUARE D METER MAIN RING T-FEED THRU OH/UG 200A
METER MAIN RING T-FEED THRU OH/UG 200A
SQUARE D Safety Switch, Fusible, 600 A, Steel
Safety Switch, Compatible with Manufacturer Model Number HRK4060, Contact Form 3PST, Current Rating 600 A, Depth 10 1/4 in, Duty Heavy Duty, Environment Indoor, For Fuse Class Class H, Class J, Class K, Class R, Fuse Kit (Class R) Mfr. No. HRK4060, Height 50 1/4 in, Horsepower @ 480V AC 400 hp, Horsepower @ 600V AC 500 hp, Housing Material Steel, IP Rating IP20, Mounting Style Surface Mount, NEMA Enclosure Rating 1, Neutral Assembly Included No
SQUARE D Safety Switch, Non-Fusible, 30 A, Steel
Safety Switch, Contact Form 3PST, Current Rating 30 A, Depth 3 3/4 in, Duty Standard, Enclosure Type Enclosed, Environment Indoor/Outdoor, For Fuse Class Not Applicable, Height 9 3/4 in, Horsepower @ 240V AC 7 1/2 hp, Housing Material Steel, IP Rating IP14, Mounting Style Surface Mount, NEMA Enclosure Rating 3R, Neutral Assembly Included No
SQUARE D Circuit Breaker Earth Leakage Module
Circuit Breaker Earth Leakage Module
SQUARE D Contactor 600Vac 60Amp Dpa +Options
Definite Purpose Magnetic Contactor
SQUARE D Miniature Circuit Breaker 240V 15A
Miniature Circuit Breaker 240V 15A, Series QOB
SQUARE D FuseHolder, NEMASizes 00;0;1;2;3;4;5;6;7
Fuse Holder, Accessory Type Fuse Holder, Current AC 6 A, NEMA Size 0, 00, 1, 2, 3, 4, 5, 6, 7, Number of Poles 2, Standards UL Listed
SQUARE D Circuit Breaker,90A,2P,525VAC,BGA
Molded Case Circuit Breaker, 90 A Amps, AC Voltage Rating 525V AC, Max. AIR Rating 100kA at 240V AC, For Use With Electrical Distribution Equipment, Industrial Control Panels, Series BGA, Circuit Breaker Type Standard, Number of Poles 2, DC Voltage Rating Not Rated, Terminal Connection Al Mechanical Lug OFF End, I-Line ON End, Trip Type Thermal Magnetic, Phase Single, Instantaneous Trip Fixed, Phase Connection AB, Frame Size 125A/BG, Circuit Breaker Mounting Style I-Line, Height 5.39 in
SQUARE D Power Distr Block,Al/Cu,600V AC/DC
Power Distribution Block 600V 350A, For Conductor Material Aluminum, Copper, Line Connections/Pole 2, For Line Copper Wire Size - Minimum 14 AWG, For Line Copper Wire Size - Maximum 2/0 AWG, Load Connections/Pole 6, For Load Copper Wire Size - Minimum 14 AWG, For Load Copper Wire Size - Maximum 4 AWG, Maximum Current - Copper Conductor 350 A, Maximum Voltage 600 V AC/DC, Mounting Type Surface Mount, Number of Poles 1, Overall Depth 2.61 in, Overall Length 4 in, Overall Width 1.94 in
SQUARE D Solid Core Current Transformer,200 Amp
Solid Core Current Transformer, Primary Range 0 to 200A, Secondary Range 0 to 5A, Hole Dia. - Current Transformer 1.13 in, Electrical Connection - Current Transformer 4 ft 18 AWG Leads, Window Round, Overall Depth 1.56 in
SQUARE D Circuit Breaker,80A,Plug In,120/240V,2P
Miniature Circuit Breaker, Amps 80 A, AC Voltage Rating 120/240V AC, Circuit Breaker Type High Interrupting Capacity, Number of Poles 2, DC Voltage Rating Not Rated, Circuit Breaker Actuator Paddle, Circuit Breaker Mounting Style Plug In, Compatible Panelboard/Load Center Series QO, Phase Single, Series QO, Max. AIR Rating 22kA at 120/240V AC, For Use With QO Load Centers and NQ Panelboards, Terminal Connection Lug, Frame Size 100A/QO, Length 3.5 in, Width 1.5 in, Depth 2.91 in
SQUARE D Circuit breaker,PowerPact H,I Line,th
Circuit breaker,PowerPact H,I Line,th
SQUARE D Clip In Marking Strip,Yellow
Warning Label
SQUARE D Circuit Brkr,PowerPact H,thermal magne
Circuit Brkr,PowerPact H,thermal magne
SQUARE D PowerPact J-Frame breaker,Micrologic 3.
PowerPact J-Frame breaker,Micrologic 3.
SQUARE D NEMAMagMotorStarter,Electronic,480VAC
NEMA Magnetic Motor Starter, Includes Auxiliary Contacts No, Maximum Overload Relay Current Setting 18 A, Overload Protection Type Electronic, Minimum Overload Relay Current Setting 6 A, Trip Class 10/20, Number of Poles 3, Number of Auxillary Contacts 0, Phase Three, Operator None, Operator Function Not Applicable, Auxiliary Contact Form Not Applicable, Starter Style NEMA, Reversing Capability Non-Reversing, Maximum Voltage Rating 600V AC, Coil Voltage 480V AC