Telecom Protection Fuse, 600 A, Not Rated, 170V DC, TPN Series, Nonindicating, Fast Acting, Body Style Blade, Rejection, 100kA at 170V DC, Fuse Size 10-3/8 in L x 2-1/2 in dia, Length 10 3/8 in, Diameter 2 1/2 in, Width Not Applicable, Depth Not Applicable, Equivalent Brand and Series Bussmann TPN, Littelfuse TLN, Mersen TGN, Equivalent Series TGN, TLN, TPN, Body Material Melamine, Single Element, Color Code No Color Code, Standards UL Recognized, Guide JFHR2, FILE E56412
Fuse, 150 A, 600V AC, Not Rated, Class J, JKS Series, Nonindicating, Fast Acting, Body Style Bolt-On, Nonrejection, Interrupt Rating 200kA at 600V AC, Fuse Size 5-3/4 in L x 1-1/2 in dia, Length 5 3/4 in, Width Not Applicable, Depth Not Applicable, Diameter 1 1/2 in, Equivalent Brand and Series Bussmann JKS, Littelfuse JLS, Mersen A4J, Equivalent Series A4J, JKS, JLS, Compatible Fuse Block Series CH30J, CH60J, J600, JM600, JM601, JM602, JM604, JM606, JP600, JT600, JTN600, Body Material Melamine
In-Line Fuse Holder, Fits Fuse Type Automotive, Fuse UL Class Not Class Rated, 0 to 20 A, Number of Poles 1, 32V DC, For Fuse Size 3/4 in L x 3/4 in W x 13/64 in D, Compatible Fuse Series 257, AF, ATC, Series HHF, Nonindicating, Nonrejection, Fuse Block Design Covered, Wire Size 16 AWG, Wire Length (2) 4 in, Mounting Style Inline, Body Material Rubber, Connector Type Wire Leads, Body Height 0.62 in, Body Width 0.9 in, Body Length 1.12 in, Features Cover
Fuse; 35 A; 250V AC; 125V DC; Class RK1; LPN-RK-SPI Series; Indicating; Time Delay; Body Style Cylindrical; Rejection; Interrupt Rating 100kA at 125V DC; 300kA at 250V AC; Fuse Size 3 in L x 13/16 in dia; Length 3 in; Diameter 13/16 in; Equivalent Brand and Series Bussmann LPN-RK-SPI; Littelfuse LLNRK-ID; Mersen A2D-R; Equivalent Series A2D-R; LLNRK-ID; LPN-RK-SPI; Compatible Fuse Block Series HM600; R250; Body Material Melamine; Dual Element
Buss Small Dimension Fuse,PK100, 10 A, 250V AC, Not Rated, Nonindicating, Time Delay, Body Style Cylindrical, Interrupt Rating 1.5k A at 250V AC, Fuse Size 20.00 mm L x 5.00 mm dia, Length 20 mm, Diameter 5 mm, Equivalent Brand and Series Bussmann S505, Equivalent Series 215, GSF, S505, Body Material Ceramic, Compatible Fuse Block Series 1A3399, H15, HHT, HTB, HTC-15M, Cap Diameter 5 1/5 in
CVR Fuse Block Covers, 0 to 30 A, 600V AC, For Fuse Class H, RK5 and RK1, Indicating, For Use With Most Brands of Fuse Blocks, Length 1.2 in, Width 2.3 in, Height 7.2 in, Standards CSA Certified, REACH, RoHS, UL Listed
Fuse, 8 A, 125V AC, Not Rated, GMA Series, Glass Fuse, Fast Acting, Body Style Cylindrical, Nonrejection, Interrupt Rating 200A at 125V AC, Fuse Size 20mm L x 5mm dia, Length 20 mm, Diameter 5 mm, Equivalent Brand and Series Bussmann GMA, Littelfuse 235, Mersen GGM, Equivalent Series 235, GGM, GMA, Body Material Glass, Compatible Fuse Block Series HTB, Single Element, Standards CE, PSE Approval, UL 248-14 Guide JDYX2 File E19180, Package Quantity 5
GMC Series Time-Delay Fuse,PK100, 1 A, 250V AC, Not Rated, Nonindicating, Time Delay, Body Style Cylindrical, Interrupt Rating 35 A at 250V AC, Fuse Size 20.00 mm L x 5.00 mm dia, Length 20 mm, Diameter 5 mm, Equivalent Brand and Series Bussmann GMC, Equivalent Series 239, GMC, GSC, Body Material Ceramic, Compatible Fuse Block Series 1A3399, H15, HHT, HTB, HTC-15M, Cap Diameter 5 1/5 in
Automotive Circuit Breaker, Mount Type Plug In, Mount Style Surface, Current Rating 20 A, Voltage Rating 14V DC, Interrupt Rating 1.5 kA at 14V DC, Terminal Connection Stud, Circuit Breaker Type Heavy Duty Circuit Breaker, Compatible Vehicle Type Trucks, Housing Material Thermoplastic/Metal, Overall Depth 9/16 in, Overall Height 1 1/4 in, Overall Width 1 11/16 in, Reset Type Automatic, Series CBC, Standards SAE J553, Stud Size #10-32
Miniature Distribution Block; For Conductor Material Aluminum; Copper; Line Connections/Pole 1; For Line Copper Wire Size - Minimum 14 AWG; For Line Copper Wire Size - Maximum 2/0 AWG; Load Connections/Pole 1; For Load Copper Wire Size - Minimum 14 AWG; For Load Copper Wire Size - Maximum 2/0 AWG; Maximum Current - Copper Conductor 175 A; Maximum Voltage 600 V AC/DC; Number of Poles 3; Overall Depth 1 in; Overall Length 3 in; Overall Width 3 in; UL 94 Flammability Rating V-0; Housing Color Black
Power Distribution Block; For Conductor Material Aluminum; Copper; Line Connections/Pole 2; For Line Copper Wire Size - Minimum 6 AWG; For Line Copper Wire Size - Maximum 350 kcmil; Load Connections/Pole 2; For Load Copper Wire Size - Minimum 6 AWG; For Load Copper Wire Size - Maximum 350 kcmil; Maximum Current - Copper Conductor 620 A; Maximum Voltage 600 V AC/DC; Number of Poles 3; Overall Depth 2.87 in; Overall Length 5.45 in; Overall Width 8.3 in; UL 94 Flammability Rating V-0
Power Distribution Block, For Conductor Material Aluminum, Copper, Line Connections/Pole 1, For Line Copper Wire Size - Minimum 2 AWG, For Line Copper Wire Size - Maximum 600 kcmil, Load Connections/Pole 12, For Load Copper Wire Size - Minimum 14 AWG, For Load Copper Wire Size - Maximum 4 AWG, Maximum Current - Copper Conductor 420 A, Maximum Voltage 600 V AC/DC, Number of Poles 3, Overall Depth 3.75 in, Overall Length 6.5 in, Overall Width 4.25 in, UL 94 Flammability Rating V-0
Fuse, 8/10 A, 250V AC, 125V DC, Class RK1, LPN-RK-SP Series, Nonindicating, Time Delay, Body Style Cylindrical, Rejection, Interrupt Rating 100kA at 125V DC, 300kA at 250V AC, Fuse Size 2 in L x 9/16 in dia, Length 2 in, Diameter 9/16 in, Equivalent Brand and Series Bussmann LPN-RK-SP, Littelfuse LLNRK, Mersen A2D-R, Equivalent Series A2D-R, LLNRK, LPN-RK-SP, Compatible Fuse Block Series HM600, R250, Body Material Melamine, Dual Element
Fuse, 35 A, 600V AC, Not Rated, Class J, JKS Series, Nonindicating, Fast Acting, Body Style Cylindrical, Nonrejection, Interrupt Rating 200kA at 600V AC, Fuse Size 2-3/8 in L x 1-1/16 in dia, Length 2 3/8 in, Width Not Applicable, Depth Not Applicable, Diameter 1 1/16 in, Equivalent Brand and Series Bussmann JKS, Littelfuse JLS, Mersen A4J, Equivalent Series A4J, JKS, JLS, Compatible Fuse Block Series CH30J, CH60J, J600, JM600, JM601, JM602, JM604, JM606, JP600, JT600, JTN600
Fuse, 8 A, 300V AC, Not Rated, GLR Series, Glass Fuse, Fast Acting, Body Style Cylindrical, Nonrejection, Interrupt Rating 10kA at 300V AC, Fuse Size 2-1/4 in L x 5/8 in dia, Length 2 1/4 in, Diameter 5/8 in, Equivalent Brand and Series Bussmann GLR, Littelfuse LGR, Mersen SLR, Equivalent Series GLR, LGR, SLR, Body Material Glass, Compatible Fuse Block Series HLR, Cap Diameter 5/8 in, Single Element, Standards CE, CSA Certification Class 1422-01, UL 248-14 Guide JDYX
Plug Fuse, 3 1/2 A, 125V AC, Not Rated, S Series, Indicating, Time Delay, Body Style Screw-In, Rejection, Interrupt Rating 10kA at 125V AC, Equivalent Brand and Series Bussmann S, Littelfuse S, Littelfuse SLO, Littelfuse SOO, Mersen S, Equivalent Series S, SLO, SOO, Body Material Ceramic, Dual Element, Standards CE, UL 248-11 Guide JFHR, File E56412, CSA Class 1423-01, File 53787, Package Quantity 4
Semiconductor Fuse; 60 A; 600V AC; Not Rated; KAC Series; Nonindicating; Fast Acting; Body Style Bolt-On; Nonrejection; Interrupt Rating 200kA at 600V AC; Fuse Size 4-3/8 in L x 13/16 in dia; Length 4 3/8 in; Diameter 13/16 in; Equivalent Brand and Series Bussmann KAC; Littelfuse KLC; Mersen A60X; Equivalent Series A60X; KAC; KLC; Compatible Fuse Block Series 1BS; Body Material Fiberglass; Single Element; Standards CE; UL Recognized
Finger-Safe Fuse Block, Body Material Thermoplastic, Compatible Fuse Series A4J, AJT, DFJ, HSJ, JKS, JLS, JTD, JTD-ID, LDFJ, LPJ, LPJ-I, Box Lug, Amp Range 0 to 30 A, Fits Fuse Type Class J, For Fuse Size 2-1/4 in L x 13/16 in dia, Fuse Block Design Finger-Safe, Nonrejection, Height 3.06 in, Length 3.11 in, Mounting Style DIN Rail, Number of Poles 1, Visual Indication Nonindicating, Voltage Rating 600V AC/DC, Width 2.42 in, Wire Range 18 to 8 AWG
Buss Small Dimension Fuse;PK100; 0.25 A; 250V AC; Not Rated; Nonindicating; Fast Acting; Body Style Cylindrical; Interrupt Rating 35 A at 250V AC; Fuse Size 20.00 mm L x 5.00 mm dia; Length 20 mm; Diameter 5 mm; Equivalent Brand and Series Bussmann S500; Equivalent Series 217; GDB; GSB; S500; Body Material Ceramic; Compatible Fuse Block Series 1A3399; H15; HHT; HTB; HTC-15M; Cap Diameter 5 1/5 in
Fuse Block; Fits Fuse Type Limiter; Fuse UL Class Not Class Rated; 10 to 800 A; Number of Poles 1; 125V AC/80V DC; For Fuse Size 3 3/16 in L x 7/8 in dia; Compatible Fuse Series ANL; ANN; CNL; CNN; Series 4164; Nonindicating; Nonrejection; Fuse Block Design Open; Mounting Style Bolt-Down; Body Material Thermoplastic; Height 1.62 in; Width 1 in; Length 3.37 in
Panel-Mount Fuse Holder, Fits Fuse Type Midget, Fuse UL Class Midget, 0 to 15 A, Number of Poles 1, 600V AC, For Fuse Size 1 1/2 in L x 13/32 in Dia., Compatible Fuse Series AGU, ATM, ATQ, BAF, BLF, BLN, FLM, FLQ, FNM, FNQ, GGU, HC10S, KLK, KLKD, KLM, KTK, OTM, TRM, Series HPS, Nonindicating, Nonrejection, Fuse Cap Style Screw Knob, Mounting Style Panel, Mounting Hole 1 1/64 in Dia., Body Material Thermoplastic, Connector Type 1/4 in Quick Connect, Diameter 1.125 in, Length 2.81 in
Fuse, 0.25 A, 250V AC, Not Rated, AGX Series, Glass Fuse, Fast Acting, Body Style Cylindrical, Rejection, Interrupt Rating 10kA at 125V AC, 35A at 250V AC, Fuse Size 1 in L x 1/4 in dia, Length 1 in, Diameter 1/4 in, Equivalent Brand and Series Bussmann AGX, Littelfuse 361, Littelfuse 362, Mersen GGX, Equivalent Series 361, 362, AGX, GGX, Body Material Glass, Compatible Fuse Block Series 3823, HFA, HHN, HK, HKP, HPF, HRK, HTB, S-8000, Single Element
CVR Fuse Block Covers, 101 to 200 A, 600V AC, For Fuse Class H, RK5 and RK1, Indicating, For Use With HM60200-1CR, HM60200-2CR, HM60200-3CR, RM60200-1CR, RM60200-2CR, RM60200-3CR, Length 10.7 in, Width 2.7 in, Height 3.6 in, Standards CSA Certified, UL Listed
Fuse, 125 A, 600V AC, 300V DC, Class RK1, LPS-RK-SPI Series, Indicating, Time Delay, Body Style Blade, Rejection, Interrupt Rating 100kA at 300V DC, 300kA at 600V AC, Fuse Size 9-5/8 in L x 1-19/32 in dia, Length 9 5/8 in, Diameter 1 19/32 in, Equivalent Brand and Series Bussmann LPS-RK-SPI, Littelfuse LLSRK-ID, Mersen A6D-R, Equivalent Series A6D-R, LLSRK-ID, LPS-RK-SPI, Compatible Fuse Block Series 1BR, R600, Body Material Melamine, Dual Element
Fuse, 9 A, 600V AC, 300V DC, Class RK1, LPS-RK-SP Series, Nonindicating, Time Delay, Body Style Cylindrical, Rejection, Interrupt Rating 100kA at 300V DC, 300kA at 600V AC, Fuse Size 5 in L x 13/16 in dia, Length 5 in, Diameter 13/16 in, Equivalent Brand and Series Bussmann LPS-RK-SP, Littelfuse LLSRK, Mersen A6D-R, Equivalent Series A6D-R, LLSRK, LPS-RK-SP, Compatible Fuse Block Series 1BR, R600, Body Material Melamine, Dual Element
Fuse Block, Fits Fuse Type Industrial, Fuse UL Class R, 201 to 400 A, Number of Poles 2, 600V AC/300V DC, For Fuse Size 8 5/8 in L x 2 3/8 in dia, Compatible Fuse Series A6D-R, A6K-R, FRS-R, KLSR, KTS-R, KWS-R, LLSRK, LPS-RK, TRS-R, Series RM, Nonindicating, Rejection, Fuse Block Design Open, Wire Range 4 AWG to 600 MCM, Mounting Style Bolt-Down; DIN Rail, Body Material Thermoplastic, Connector Type Box Lug, Height 4.8 in, Width 7.3 in, Length 9.5 in
Fuse, 50 A, 250V AC, 250V DC, Class RK1, KTN-R Series, Nonindicating, Fast Acting, Body Style Cylindrical, Rejection, Interrupt Rating 100kA at 250V DC, 200kA at 250V AC, Fuse Size 3 in L x 81/100 in dia, Length 3 in, Diameter 81/100 in, Equivalent Brand and Series Bussmann KTN-R, Littelfuse KLNR, Mersen A2K-R, Equivalent Series A2K-R, KLRN, KTN-R, Compatible Fuse Block Series R250, RM250, RM251, RM252, RM254, RM256, RM600, RM601, RM602, RM604, RM606, Body Material Melamine, Single Element
Plug Fuse, 8A, 125V AC, Not Rated, S Series, Indicating, Time Delay, Body Style Screw-In, Rejection, Interrupt Rating 10kA at 125V AC, Equivalent Brand and Series Bussmann S, Littelfuse S, Littelfuse SLO, Littelfuse SOO, Mersen S, Equivalent Series S, SLO, SOO, Body Material Ceramic, Dual Element, Standards CE, UL 248-11 Guide JFHR, CSA Class 1423-01, Package Quantity 4
Fuse Block, Fits Fuse Type Industrial, Fuse UL Class R, 0 to 30 A, Number of Poles 1, 250V AC/125V DC, For Fuse Size 2 in L x 9/16 in dia, Compatible Fuse Series A2D-R, A2K-R, FLNR, FRN-R, KLNR, KTN-R, KWN-R, LLNRK, LPN-RK, TR-R, Series RM, Nonindicating, Rejection, Fuse Block Design Open, Wire Range 14 to 2 AWG, Mounting Style Bolt-Down; DIN Rail, Body Material Thermoplastic, Connector Type Box Lug, Height 2 in, Width 1 in, Length 3.2 in, Standards CE, CSA Certified, REACH, RoHS, UL Listed
Power Distribution Block, For Conductor Material Aluminum, Copper, Line Connections/Pole 1, Line Side Stud Size 3/8-16 x 1-7/16 In., Load Connections/Pole 2, Load Side Stud Size 1/4-20 x 9/16 In., Maximum Current - Copper Conductor 310 A, Maximum Voltage 600 V AC/DC, Number of Poles 3, Overall Depth 3.75 in, Overall Length 6.5 in, Overall Width 1.88 in, UL 94 Flammability Rating V-0, Housing Color Black, Housing Material Thermoplastic, Line Side Connection Type Stud