Close
Noble
Free Shipping on orders over $100 - CONUS ONLY
Home
Filters
Apply Filters

NARROW DOWN


COUNTRY OF ORIGIN
-

United States

China

Germany


CONTRACT
-

47QSCCD0007

47QSEA19D00AY


COUNTRY_OF_ORIGIN
-

-

China

Costa Rica

Czech Republic

Denmark

France

GREAT BRITAIN

Germany

India

Italy

Malaysia

Mexico

Romania

Singapore

Taiwan

Thailand

United States

Vietnam


MANUFACTURER
-

Pyramex Safety Products


PROP_65_INDICATOR
-

Y


BRAND
-
FLUKE AC Clamp OnCurrent Probe,3 to 3000A
Clamp On Current Probe, Connector Type BNC, For Use With Fluke 120B Series, Maximum AC Current Measurement 3,000 A, Minimum AC Current Measurement 30 A, Maximum Conductor Size 7 in, Output 100mV/A, 10mV/A, 1mV/A, Parameters Measured AC Current, AC Voltage, DC Voltage, Safety Rating CAT III 600V, Probe Type Flexible, Jaw Opening 10.5 in, Battery Chemistry Alkaline, Battery Size AA, Battery Voltage 1.5V DC, Manufacturers Warranty Length 1 yr, Maximum AC Voltage Measurement 600 V
FLUKE Multimeter; Auto Kit; LCD
Automotive Multimeter Kit; Product Type Automotive Multimeter Kit; Display Type LCD; Voltage 1;000V; Maximum Frequency 200 KHz; Maximum Speed 12;000 RPM; 9;000 RPM; Minimum Speed 30 RPM; 60 RPM; Maximum Resistance 50 megaohm; Maximum Duty Cycle 99.9 Percent
FLUKE Drywell,Temperature
Drywell, Field Metrology Well, Fluke 9143, -196 Degrees to 660 Degrees C, 0 Degrees to 1,480 Degrees C, Calibration Details NVLAP Accredited Calibration Included, Interface RS-232, 11 13/32 in H x 7 5/16 in W x 11 39/64 in D
FLUKE I V Curve Tracer with 1 Year FPC
I V Curve Tracer with 1 Year FPC, Display No Display, Open Circuit Voltage Measurement - Minimum 20 V DC, Open Circuit Voltage Measurement - Maximum 1,500 V DC, Insulation Resistance Measurement - Minimum 200 kiloohm, Insulation Resistance Measurement - Maximum 500 gigohm, Datalogging Yes, Includes Solmetric PVA-1500HE2 with 1 Year of Fluke Premium Care, Manufacturer Warranty 1 yr
FLUKE Digital Pressure Gauge,4-1/4 in,0-3000
Digital Test Pressure Gauge, Accuracy +/-0.02 Percent, Gauge Case Material Cast Zinc Aluminum, Nominal Dial Size 4 1/4 in, IP/NEMA Rating Not Rated, Hazardous Location Rating Not Rated, Compatible Process Media Any Clean Dry Non-Corrosive Gas, Any Liquids or Gases Compatible With 316 Stainless Steel, Any Non-Flammable, Non-Toxic, Non-Explosive, Non-Oxidizing Liquid or Gas Compatible With 316 Stainless Steel, Socket Material Zinc Alloy, Process Connection Type NPT, Display Units psi
FLUKE Water Cooling Enclosure, c/w-Fluke
Cooling Jacket and Air Purge, Features The Water Cooling Enclosure Allows the Camera to be used in High Ambient Temperatures with Water Cooling, Compatible with Series ThermoView TV30, Overall Depth 22 3/4 in, Overall Height 14 3/4 in, Overall Width 11 3/8 in, Product Type Water Cooling Enclosure, Compatible with Brand Fluke
FLUKE Test Lead Kit,10A
Test Lead Kit, For Use With Any Multimeter, Clamp Meter, or Test Instrument that Accepts a Standard Shrouded Banana Plug, Includes AC285 Suregrip(TM) Large Jaw Alligator Clips, C33, Soft Carrying Case, Tp238 Suregrip(TM) Insulated Test Probe Set, Length Not Applicable, Maximum Voltage 1,000 V, Instrument Safety Rating CAT III 1000V, CAT IV 600V, Test End Termination Alligator Clip, Probe, Maximum Current 10 A, Meter Connection Type Standard Shrouded Banana Plug, Number of Modular Test Clips 1
FLUKE Hydraulic Test Pump,Up to 10000 psi
Hydraulic Test Pressure Kit, For Use With Fluke Pressure Calibrators, Function Hydraulic Pressure, Up to 10,000 psi, 1/8 and 1/4 Adapter Thread Fitting (F)NPT, Features Generate Pressure upto 10,000 psi (690 bar) with the Included 700HTP-2 Test Pump, Includes Hard Case, Transmitter Test Hose Kit
FLUKE Drywell,Temperature
Drywell, Field Metrology Well, Fluke 9144, -196 Degrees to 660 Degrees C, 0 Degrees to 1,480 Degrees C, Calibration Details NVLAP Accredited Calibration Included, Interface RS-232, Number of Set Points Variable, 11 13/32 in H x 7 5/16 in W x 11 39/64 in D
FLUKE Universal Battery Eliminator,345
Universal Battery Eliminator,345
FLUKE IR Thermometer, SingleDot,-40 to 1472F
Infrared Thermometer, Laser Sighting Type Single Dot, Secondary Measuring Method Type K Thermocouple, Emissivity Adjustability Adjustable, Distance To Spot Ratio 50:1, Alert Type Digital Display, Light, Sound, Field of View Not Applicable, Minimum Emissivity Setting 0.10, Maximum Emissivity Setting 1.00, Minimum Temperature Measured Degrees F -40 Degrees F, Maximum Temperature Measured Degrees F 1,472 Degrees F, Minimum Operating Temperature Degrees F 32 Degrees F
FLUKE Electronic Deadweight Tester,10,000 psi
Electronic Deadweight Tester, Pressure Range 0 to 10,000 psi, Accuracy 0.02 Percent Reading, Displayed Pressure Units bar, custom, hPa, inH2O, inHg, kcm2, kPa, mbar, mmH2O, mmHg, mTorr, Pa, psf, psi, Torr, Calibration Certificate ISO, Display 2 x 20 Vacuum Fluorescent Display, Interface RS-232, Powered By 100 to 240V AC, 50/60 Hz, Standards ISO, Includes Power Supply
FLUKE Drywell;Temperature Calibrator
Thermometer Calibrator; Fluke 7103; Portable Calibration Baths; Includes NIST-Traceable Certificate Yes; -30 Degrees to 125 Degrees C; 13 13/64 in H x 9 in W x 10 1/2 in D; Fluid Volume 1 L; Tank Size 2 1/2 in Dia x 5 1/2 in D Tank; 1 29/32 in Working Diameter
FLUKE Pressure Calibrator,-12 to 30 psi
Handheld Pressure Calibrator, Internal Electric Pump Pressure Source, Measurement Functions mA DC, Pressure, Temperature, VDC, Internal Pressure Measurement Range -12 to 30 psi, Internally Generated Pressure Range -12 to 30 psi, Pressure Range with External Modules -15 psi to 10,000 psi, Loop Supply Voltage 24 V DC, Current Measurement Range 0 to 24mA DC, Source Current 4 to 20mA DC, Voltage Measurement Range 0 to 30V DC, RTD Temperature Range -40 Degrees to 150 Degrees C, Display Multiline LCD
FLUKE Norma 4000 Precision Power Analyzer,3PH
Norma 4000 Precision Power Analyzer,3PH
FLUKE Tele Lens; 320x240IR Res; 22x 16FOV
TV33 FIXED TI;Tele Lens; Frame Rate 60 Hz; Calibration Certificate Type Available Separately; Alert Type Digital Display; Data Transfer Type Wireless; Digital Display Screen Type LED; Emissivity Adjustability Adjustable; Maximum Emissivity Setting 1.00; Minimum Emissivity Setting 0.10; Thermal Sensitivity 80 mK; 120 mK; Minimum Focus Distance 7.5 in; Minimum Operating Temperature Degrees F 14 Degrees F; Minimum Temperature Measured Degrees F 14 Degrees F
FLUKE Retractable Tip Test Lead,1.5 m L,PR
Test Leads, Color Code Black, Red, For Use With Clamp Meter, Digital Multimeter, mA Loop Calibrators, Portable Oscilloscope, Power Quality Analyzes, Length 4 7/8 ft, Maximum Voltage 1,000 V, Number of Test Leads 2, Instrument Safety Rating CAT II 1000V, CAT III 1000V, CAT IV 600V, Maximum Current 10 A, Meter Connection Type Right Angle Shrouded Plug, Features Heavy-Duty Strain Relief, Wearguard Silicone Leads Indicate When to Replace Leads, Manufacturers Warranty Length 1 yr
FLUKE Alligator Clips, FTP,FTPL,FTP1,FTPL1
Alligator Clips, FTP,FTPL,FTP1,FTPL1
FLUKE True-Rms Logging Multimeter W/Trndcaptre
True-Rms Logging Multimeter W/Trndcaptre
FLUKE Drywell,Temperature Calibrator
Drywell, Field Metrology Well, Fluke 9190A, -139 Degrees to 284 Degrees F/-95 Degrees to 140 Degrees C, Interface RS-232, USB Cable, Number of Set Points Variable, 18 13/16 in H x 8 in W x 14 29/32 in D
FLUKE Insulation Tester,Display LCD,10.6" L
Insulation Tester, Backlit Digital Display No, Bluetooth Compatible Yes, CAT Safety Rating CAT II, CAT III 1000V, CAT IV 600V, Calibration Certificate Included, Capacitance Auto Discharge No, Display Type Analog, Digital, Dustproof No, Greater Than 30V Warning Yes, Includes AC Power Cord, Heavy Duty Alligator Clip Leads, InfraRed Adapter with Interface Cable, IP67 Hard Case, Quick Reference Card, Test Cables with Alligator Clips (Red, Black, Green), USB-IR Cable Installation Guide
FLUKE Test Pump,Hydraulic,0 To 10K PSI
Hydraulic Test Pump, Features Directly Connection to Pressure Modules Consolidates Two Separate Pieces into One when Performing Pressure Calibration and Testing, Improved Priming, Improved Stroke Limiting Mechanism, Integral Pressure Adjustment Vernier Knob for Fine Pressure Adjustment, Variable Size Stroke Adjustment, Allows the user to Vary the Volume and Pressure per Stroke, Includes (2) 1/4 in NPT male to 1/4 in BSP Female adapters
FLUKE Norma 4000 Precision Power Analyzer,3PH
Norma 4000 Precision Power Analyzer,3PH
FLUKE Test Lead Kit,10A,59 In. L
Test Lead Kit, For Use With Any Multimeter, Clamp Meter, or Test Instrument that Accepts a Standard Shrouded Banana Plug, Includes AC220 Suregrip(TM) Alligator Clip Set, Insulated Test Probe Set, TL224 Suregrip(TM) Silicone Test Lead Set, TP220 Suregrip(TM), Length 4 11/12 ft, Maximum Voltage 1,000 V, Maximum Temperature Measurement Not Applicable, Minimum Temperature Measurement Not Applicable, Instrument Safety Rating CAT II 1000V, Test End Termination Alligator Clip, Probe
FLUKE Rplcmt Bladehead,For  61110,5G110,6110G
Replacement Bladhead, Blade Configuration Terminate/Cut, Compatible with Manufacturer Model Number JR-LEV-2, Compatible Block Type Leviton 5G110; Leviton 6110G; Leviton 61110, Compatible Product Type Leviton, Includes Blade Head, Product Type Replacement Bladhead
FLUKE Full Ops Training,Single Seat
OPS TRAINING - FULL - ON DEMAND VIRTUAL PER SEAT
FLUKE Access Cover,Metal Blank Access
Access Cover, Spare Tank Lid, Compatible Product Type Liquid Bath Calibrators, Number of Holes 0
FLUKE Alligator Clip,Pk3
Alligator Clip, For Use With 120 Series Handheld Digital Storage Oscilloscopes, Includes Black Clip, Package Quantity 3
FLUKE Pressure Module,Gage
Pressure Module, Gage, Pressure Range 0 to 300 psi (0 to 2000 KPa), Total Uncertainty 0.035 Percent, High Side Compatible With 316 Stainless Steel, Fitting Material Stainless Steel, For Use With Fluke Calibrators, NIST Traceable Calibration Certificate, Includes Adapters, Certificate of Calibration, Manufacturers Warranty Length 3 yr.
FLUKE Twist Guard TM Test Leads,Dia Probe Tips
Twist Guard TM Test Leads,Dia Probe Tips