Filters
Ductless Enclosure, Filter Type Not Applicable, Overall Height 30 in, Overall Width 34 in, Overall Length 34 in, Voltage Not Applicable, Number of Filters Required Not Applicable, For Use With Airborne Particulates, Series Purair Vented Enclosure
Fume Hood Cart; Depth 28 in; Load Capacity 300 lb; Door Type Not Applicable; Material Powder-Coated Steel; Number of Shelves 0; Number of Doors 0; Number of Drawers 0; For Use With Purair 10 Ductless Fume Hood; Includes Casters
Filter; HEPA; 20 in; 4 in; 20 in; Filter Efficiency 99.99 Percent Efficient on 0.3 micron Particles; For Use With Ductless Fume Hoods; Not Applicable; Includes Not Applicable
Filter; 21 in; 4 in; 21 in; Filter Efficiency Varies by Chemical; For Use With Solvents; Not Applicable; Includes Not Applicable
PCR Workstation; Filter Type HEPA; Prefilter; ULPA; 250 cfm CFM; Overall Height 35 in; Overall Width 36 in; Overall Length 36 in; Inside Height 24 in; Inside Length 35 1/2 in; Inside Width 25 1/2 in; Opening Size 8 in; 0.4 hp HP; Voltage 115V AC; Number of Filters Required 1; Polycarbonate; Polypropylene; Powder-Coated Steel; Compliance UL 61010; Width 36 in; Depth 26 in; Height 35 in; Voltage (AC) 115V; For Use With Mfr. No. CART M15; Series Purair PCR
Fume Hood Work Surface; For Use With Purair 15 Ductless Fume Hood
Filtering Storage Cabinet; Filter Type Carbon; HEPA; Prefilter; ULPA; 250 cfm CFM; Overall Height 29 in; Overall Width 34 in; Overall Length 34 in; Inside Height 16 in; Inside Length 33 in; Inside Width 19 in; Opening Size 12 in; 0.4 hp HP; Voltage 115V AC; Number of Filters Required 1; Acrylic; Polypropylene; Compliance UL 61010; Width 34 in; Depth 20 in; Height 29 in; Voltage (AC) 115V; For Use With Instructional Laboratories; Series SafeSTORE Vented Chemical Storage Cabinets
Carbon Filter; For Organics And Solvents; 20 in; 4 in; 20 in; Filter Efficiency Varies by Chemical; For Use With Ductless Fume Hoods; Not Applicable; Includes Not Applicable
Ductless Fume Hood; Filter Type Carbon; HEPA; Prefilter; ULPA; 440 cfm CFM; Overall Height 4 3/8 ft; Overall Width 5 3/4 ft; Overall Length 69 in; Voltage 115V AC; Number of Filters Required 2; For Use With Hazardous Vapors; Series Purair Advanced
Spill Tray, Polypropylene, For Use With 48 In. Wide Purair Basic(TM) Ductless Fume Hood
Fume Box Filtering Unit, Filter Type Carbon, HEPA, Prefilter, ULPA, Overall Height 12 in, Overall Width 21 1/4 in, Voltage 115V AC, Number of Filters Required 1, Width 21 1/4 in, Depth 19 3/4 in, Height 12 in, For Use With Fumes, Vapors or Powders in Laboratory Environments, Series Fume Box
Filter, Carbon And HEPA, 20 in, 4 in, 20 in, Filter Efficiency Varies by Chemical, For Use With Powders, Not Applicable, Includes Not Applicable
Filter; Carbon; 19 in; 1 1/2 in; 19 in; Filter Efficiency Varies by Chemical; For Use With Fuming Chambers; Not Applicable; Includes Not Applicable
Filter; HEPA; 19 in; 1 1/2 in; 19 in; Filter Efficiency 99.97 Percent Efficient on 0.3 micron Particles; For Use With Powders; Not Applicable; Includes Not Applicable
Clean Bench; Filter Type HEPA; Prefilter; ULPA; 350 cfm CFM; Overall Height 42 1/4 in; Overall Width 6 3/8 ft; Overall Length 76 in; Voltage 115V AC; Number of Filters Required 1; For Use With Laboratory Equipment; Series Purair LF
Vented Balance Enclosure Fume Extractor
Filtering Storage Cabinet; Filter Type Carbon; HEPA; Prefilter; ULPA; 500 cfm CFM; Overall Height 5 7/8 ft; Overall Width 5 1/4 ft; Overall Length 64 in; Inside Height 64 in; Inside Length 63 in; Inside Width 23 in; Opening Size 60 in; 0.8 hp HP; Voltage 115V AC; Number of Filters Required 1; Acrylic; Polypropylene; Compliance UL 61010; Width 64 in; Depth 24 in; Height 79 in; Voltage (AC) 115V; For Use With Instructional Laboratories; Series SafeSTORE Vented Chemical Storage Cabinets
Fume Hood Work Surface; For Use With Purair 40 Ductless Fume Hood
Evidence Drying Cabinet; Filter Type Carbon; HEPA; Prefilter; ULPA; 295 cfm CFM; Overall Height 6 1/4 ft; Overall Width 5 ft; Overall Length 75 in; Voltage 115V AC; Number of Filters Required 2; For Use With Uncontrolled Environments
Ductless Fume Hood; Filter Type Carbon; HEPA; Prefilter; ULPA; 136 cfm CFM; Overall Height 35 in; Overall Width 27 in; Overall Length 24 in; Voltage 115V AC; Number of Filters Required 1; Series PurairRX
Continuous Airflow Display; For Use With Purair Basic(TM) Ductless Fume Hoods
PCR Workstation; Filter Type HEPA; Prefilter; ULPA; 500 cfm CFM; Overall Height 35 in; Overall Width 4 ft; Overall Length 48 in; Inside Height 24 in; Inside Length 47 1/2 in; Inside Width 25 1/2 in; Opening Size 8 in; 0.8 hp HP; Voltage 115V AC; Number of Filters Required 2; Polycarbonate; Polypropylene; Powder-Coated Steel; Compliance UL 61010; Width 48 in; Depth 26 in; Height 35 in; Voltage (AC) 115V; For Use With Mfr. No. CART M20; Series Purair PCR
Filter; Carbon For Acids; 18 in; 1 3/4 in; 18 in; Filter Efficiency Varies by Chemical; For Use With Acids; Not Applicable; Includes Not Applicable