Filters
Air Velocity Probe, Compatible Product Type Data Logging Air Quality Meters, Product Type Replacement Carbon Dioxide Probe, Compatible with Grainger Part Number 56HN84, Compatible with Manufacturer Model Number R9910SD, SD-9901, Overall Height 7 1/2 in, Overall Length 1 1/2 in, Overall Width 1 1/8 in
Sound Level Meter, Includes Carrying Case, Data Logger, Sound Level Meter, USB Cable, Windshield Ball, Digital Display Screen Type LCD with Backlight, Frequency Weighting A, C, Maximum Frequency Measurement 8 kHz, Maximum Sound Level Measurement 130 dB, Minimum Frequency Measurement 20 Hz, Minimum Sound Level Measurement 30 dB, Number of Records Stored 64,000, Sound Level Measurement Accuracy +/-1.4 dB, Sound Level Measurement Resolution 0.1 dB, Interface USB, Features Bar Graph Display
Indoor Air Quality Meter; Calibration Certificate Type Available Separately; Digital Display Screen Type LCD with Backlight; Features Calculates Time-Weighted Average (TWA) and Short-Term Exposure Limit (STEL); Triple LCD Display; Includes Carrying Case; USB Cable; Maximum Carbon Dioxide Measured 30;000 ppm; Maximum Carbon Monoxide Measured Not Applicable; Maximum Dew Point Measured Not Applicable; Maximum Oxygen Measured Not Applicable; Maximum Pressure Measured Not Applicable
HD Video Inspection Camera System
Ultrasonic Thickness Gauge, Includes Carrying Case, Probe, Ultrasonic Couplant Gel, Ultrasonic Thickness Gauge, Thickness Measurement Accuracy +/-0.1 Percent, Thickness Measurement Resolution 0.01 in, Calibration Certificate Type Available Separately, Maximum Frequency 5 MHz, Maximum Thickness Measured 15.7 in, Minimum Thickness Measured 0.03 in, Maximum Velocity 9,999 mps, Minimum Velocity 990 mps, Number of Digits 4, Minimum Frequency 5 MHz, Number of Records Stored 500, Standards CE
Probe;Type K;Male Thermocouple
Replacement Probe, Product Type Replacement Probe, Compatible with Manufacturer Model Number R7900, Compatible Product Type Ultrasonic Thickness Gauge, Features 5 MHz Frequency, Includes Ultrasonic Thickness Gauge Probe, Steel Thickness - Maximum 15.70 in, Steel Thickness - Minimum 0.04 in, Overall Diameter 0.78 in, Calibration Certificate Type Not Certified, Overall Height Not Applicable, Overall Length Not Applicable, Overall Width Not Applicable, Manufacturer Warranty Length 1 yr
Baker Viscosity Cup; Viscosity Range 146 to 848 cSt; Height 305 mm; Standards ASTM D4212; ASTM D1084; ASTM D816
Hot Wire, Probe Diameter 0.5 in, Probe Type Hot Wire, Relative Humidity Accuracy Not Applicable, Connector Type J-Type, K-Type, Maximum Hot Wire Probe Length 37 in, Minimum Hot Wire Probe Length 11 in, Minimum Temperature Measured 32 Degrees F, Minimum Velocity Measured 40 fpm, Air Velocity Resolution 1 fpm, Maximum Temperature Measured 122 Degrees F, Maximum Velocity Measured 4,921 fpm, Compatible with Manufacturer Model Number R4500SD, SD-4214, Temperature Accuracy +/ 1.5 Degrees
Refractometer, Brix, Range 0 Percent to 32 Percent Brix, Accuracy +/-0.2 Percent, Resolution 0.2, Function Measures The Concentration of Sugar In Fruit Juice, Features Calibrated to Sucrose Content Contained In 100 g of Cane Sugar, Easy to Operate with Simple to Read Scales, Prism and Lens with A Simple Focus Adjustment Provides Repeatable Results, Requires Only 2 or 3 Drops of Sample, Length 6 1/2 in, Width 1 in, Height 1.5 in
Replacement Extension Shaft for R7100
Food Service Infrared Thermometer; Alert Type Digital Display; Sound; Maximum Emissivity Setting Fixed 0.95; Digital Display Screen Type LCD with Backlight; Response Time 1 sec; Standards CE; Battery Voltage 9V; Batteries Included Yes
Thermocouple Bead Probe; Type K; For Application Surface; Mini Plug; Probe Size 1/2 in x 7.9 in; Cable Length 39 in; -58 Degrees to 932 Degrees F/-50 Degrees to 500 Degrees C; Thermocouple
Thermocouple Wire Probe; Type K; For Application Surface; Mini Plug; Probe Size 1/8 in x 1/2 in; Cable Length 38 in; -40 Degrees to 482 Degrees F/-40 Degrees to 250 Degrees C; Thermocouple
Insulation/Resistance Meter; Tester Type Voltage Detector/Tester
Baker Viscosity Cup; Viscosity Range 460 to 1;840 cSt; Height 305 mm; Standards ASTM D4212; ASTM D1084; ASTM D816
Infrared Thermometer; Laser Sighting Type Single Dot; Secondary Measuring Method No Secondary Measuring Method; Emissivity Adjustability Adjustable; Distance To Spot Ratio 12:1; Alert Type Light; Sound; Field of View Not Applicable; Minimum Emissivity Setting 0.10; Maximum Emissivity Setting 1.00; Minimum Temperature Measured Degrees F -31 Degrees F; Maximum Temperature Measured Degrees F 1;202 Degrees F; Minimum Operating Temperature Degrees F 32 Degrees F
Surface Wheel Adapter for Tachometers
Contact/Laser Tachometer w/NIST
Data Logging Force Gauge; Maximum Force Measured 44 lbf; Minimum Force Measured 20 kgf; Force Resolution 0.01 kg/0.01 lb/0.02 N; Force Accuracy +/-0.5 Percent; Measuring Units kg; lbf; N; Display Type Digital; Analog Display Graduation Not Applicable; Includes Extension Rod; Flat Head; Cone Head; Chisel Head and Hook Adapters; Hard Carrying Case; Digital Display Screen Type LCD; Number of Records Stored 99; Auto Power Off Yes; Manufacturer Warranty Length 1 yr; Number of Digits 4
Sound Level Adaptor; Features Electric Condenser Microphone; Frequency Weighting Networks are Designed to Meet the IEC 61672 Class 2; Low Battery Indicator; Product Type Sound Level Adapter; Compatible with Manufacturer Model Number R4700SD; SD-9300; Meter Adaption Dosimeter; Compatible with Grainger Part Number 52ZK67; 56HN68; Overall Height 4 1/4 in; Overall Length 2 1/8 in; Overall Width 1 1/8 in; Calibration Over/Under Indicator
Milli-Ohmmeter;110V;Cat. II;230V; CAT Safety Rating CAT II; Display Type Digital; Insulation Resistance Resolution 0.1 milliohm to 1 ohm; Power Source 110V AC 50/60Hz; Includes 4 Wire With 2 Kelvin Clips; Milli Ohmmeter 110V; Power Cord; Protective Case; Shoulder Strap
Ultrasonic Thickness Gauge; Includes Carrying Case; Probe; Ultrasonic Couplant Gel; Thickness Measurement Accuracy +/-0.5 Percent; Thickness Measurement Resolution 0.001 in; Calibration Certificate Type NIST; Maximum Frequency 5 MHz; Maximum Thickness Measured 7.9 in; Minimum Thickness Measured 0.05 in; Maximum Velocity 9;000 mps; Minimum Velocity 500 mps; Number of Digits 4; Minimum Frequency 5 MHz; Number of Records Stored 0; Standards CE; Digital Display Screen Type LCD
Continuity Tester; Alert Type Light; Sound; Built-In Flashlight No; CAT Safety Rating Not Rated; Display Type No Display; Maximum AC Voltage Measured Not Applicable; Maximum DC Voltage Measured Not Applicable; Non-Contact No; Test Connection Type Probe Tip; Testing Functions Local and Remote Continuity; Features Lightweight Design; Connect Alligator Clips and the Instrument Suspends from Wire/Cable; Power Source Battery; Tester Type Continuity Tester; Battery Size 9V