DRAEGER RA/P Facepiece Adaptor Assembly
RA/P Facepiece Adaptor Assembly, For Use With SCBA Full Face Pieces, Panorama Nova Positive Pressure
DRAEGER Detector Tube,Carbon Monoxide,PK10
Detector Tube, Measurement Range 100 to 3,000 ppm/10 to 300 ppm, Gas Detected Carbon Monoxide, For Use With Mfr. No. 6400000, Color Change White to Brown Green, Operating Pressure 1,013 hPa, Operating Temperature - Minimum 32 Degrees F, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Shelf Life 2 yr, Application Civil Defense, Fire Brigades, Industrial Applications, Military, Includes Instructions
DRAEGER Chip,Hydrogen Peroxide,0.2 to 2 ppm
Detector Chip, Measurement Range 0.2 to 2 ppm, Gas Detected Hydrogen Peroxide, For Use With CMS Analyzer, Operating Pressure 700 to 1,100 hPa, Operating Temperature - Minimum 50 Degrees F, Tube Material Plastic, Calibrated Yes, Product Type Detector Chip, Sampling Time 180 to 600 sec (0.2 to 2 ppm), Chemical Formula H2O2, CAS Number 7722-84-1, Operating Temperature - Maximum 86 Degrees F
DRAEGER Detector Tube,Water Vapor,PK10
Detector Tube, Measurement Range 1 to 40 mg/L, Gas Detected Water Vapor, For Use With Mfr. No. 6400000, Color Change Yellow to Red Brown, Operating Pressure 1,013 hPa, Operating Temperature - Minimum 32 Degrees F, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Shelf Life 2 yr, Application Civil Defense, Fire Brigades, Industrial Applications, Military, Includes Instructions, Sampling Time 2 min (1 to 40 mg/L), Chemical Formula H2O, CAS Number 7732-18-5
DRAEGER Detector Tube,Carbon Monoxide,PK10
Detector Tube, Measurement Range 5 to 150 ppm, Gas Detected Carbon Monoxide, For Use With Aerotests, Color Change White to Brownish Green, Operating Pressure 1,013 hPa, Operating Temperature - Minimum 32 Degrees F, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Shelf Life 2 yr, Application Civil Defense, Fire Brigades, Industrial Applications, Military, Includes Instructions, Sampling Time 5 min (5 to 150 ppm), Sampling Volume 1,000 mL
DRAEGER Float Probe,For X-am 7000
Float Probe, Product Type Float Probe, Power Source Not Applicable, For Use With X-am 7000, Probe Diameter 3 in
DRAEGER Remote Sampling Module
Colorimetric Sample Draw Pump, Product Type Colorimetric Sample Draw Pump, Power Source Battery, Includes Pump, Features Chip Contains 10 Measurement Channels Filled with A Substance Specific Reagent That Provides A Quick Reaction with The Contaminant, Data Recorder Gives Contaminant, Concentration, Date, Time, and Location, Simple Menu Commands and One Switch Operation, Intelligent Interaction Ensures High Level of Accuracy, Stores Up to 50 Measurements, For Use With Mfr. No. 6405300
DRAEGER Detector Tube,Sulfur Dioxide ,PK10
Detector Tube, Measurement Range 1 to 25 ppm, Gas Detected Sulfur Dioxide, For Use With Mfr. No. 6400000, Color Change Gray Blue to White, Operating Pressure 1,013 hPa, Operating Temperature - Minimum 59 Degrees F, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Shelf Life 2 yr, Application Civil Defense, Fire Brigades, Industrial Applications, Military, Includes Instructions, Sampling Time 3 min (1 to 25 ppm), Chemical Formula SO2, CAS Number 7446-09-5
DRAEGER Detector Tube,Hydrogen Sulfide,PK10
Detector Tube, Measurement Range 10 to 200 ppm/1 to 20 ppm, Gas Detected Hydrogen Sulfide, For Use With Mfr. No. 6400000, Color Change White to Brown, Operating Pressure 1,013 hPa, Operating Temperature - Minimum 35.6 Degrees F, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Shelf Life 2 yr, Application Civil Defense, Fire Brigades, Industrial Applications, Military, Includes Instructions, Sampling Time 1/10 min (10 to 200 ppm/1 to 20 ppm)
DRAEGER PC Comm Set;USB DIRA w/USB Cable
PC Communication Set; Product Type USB DIRA; Series X-am 5600; Communication Protocol USB; Features USB Interface Works with Windows XP and Windows 7; For Use With Draeger X-am 5600; Includes Communication Adapter; USB Cable
DRAEGER Detector Tube,Phosphine,PK10
Detector Tube, Measurement Range 50 to 1,000 ppm, Gas Detected Phosphine, For Use With Mfr. No. 6400000, Color Change Yellow to Brown Black, Operating Pressure 1,013 hPa, Operating Temperature - Minimum 32 Degrees F, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Shelf Life 2 yr, Application Civil Defense, Fire Brigades, Industrial Applications, Military, Includes Instructions, Sampling Time 2 min (50 to 1,000 ppm), Chemical Formula PH3
DRAEGER Detector Tube,Mercaptans,PK10
Detector Tube, Measurement Range 20 to 100 ppm, Gas Detected Mercaptans, For Use With Mfr. No. 6400000, Color Change White to Yellow Brown, Operating Pressure 1,013 hPa, Operating Temperature - Minimum 32 Degrees F, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Shelf Life 2 yr, Application Civil Defense, Fire Brigades, Industrial Applications, Military, Includes Instructions, Sampling Time 2.5 min (20 to 100 ppm), Chemical Formula RSH
DRAEGER Detector Tube,Carbon Dioxide,PK10
Detector Tube, Measurement Range 100 to 3,000 ppm, Gas Detected Carbon Dioxide, For Use With Aerotests, Color Change White to Violet, Operating Pressure 1,013 hPa, Operating Temperature - Minimum 59 Degrees F, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Shelf Life 2 yr, Application Civil Defense, Fire Brigades, Industrial Applications, Military, Includes Instructions, Sampling Time 5 min (100 to 3,000 ppm), Sampling Volume 1,000 mL
DRAEGER Detector Tube,Formic Acid,1to15ppm,PK10
Detector Tube, Measurement Range 1 to 15 ppm, Gas Detected Formic Acid, For Use With Mfr. No. 6400000, Color Change Blue Violet to Yellow, Operating Pressure 1,013 hPa, Operating Temperature - Minimum 50 Degrees F, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Shelf Life 2 yr, Application Civil Defense, Fire Brigades, Industrial Applications, Military, Includes Instructions, Sampling Time 3 min (1 to 15 ppm), Chemical Formula CH2O2, CAS Number 64-18-6
DRAEGER Detector Tube,Carbon Dioxide,PK10
Detector Tube, Measurement Range 0.5 to 10 Percent vol, Gas Detected Carbon Dioxide, For Use With Mfr. No. 6400000, Color Change White to Violet, Operating Pressure 1,013 hPa, Operating Temperature - Minimum 32 Degrees F, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Shelf Life 2 yr, Application Civil Defense, Fire Brigades, Industrial Applications, Military, Includes Instructions, Sampling Time 30 sec (0.5 to 10 Percent vol), Chemical Formula CO2
DRAEGER Detector Tube,Multi Gases Qual,PK10
Detector Tube, Measurement Range Qualitative, Gas Detected Polytest, For Use With Mfr. No. 6400000, Color Change White to Brown, Green/Violet, Operating Pressure 1,013 hPa, Operating Temperature - Minimum 32 Degrees F, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Shelf Life 2 yr, Application Civil Defense, Fire Brigades, Industrial Applications, Military, Includes Instructions, Sampling Time 1.5 min, Operating Temperature - Maximum 122 Degrees F
DRAEGER Detector Tube,Carbon Disulfide,PK10
Detector Tube, Measurement Range 5 to 60 ppm, Gas Detected Carbon Disulfide, For Use With Draeger Accuro Pump, Color Change White to Brown Green, Operating Pressure 1,013 hPa, Operating Temperature - Minimum 32 Degrees F, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Shelf Life 2 yr, Application Civil Defense, Fire Brigades, Industrial Applications, Military, Includes Instructions, Sampling Time 3 min (5 to 60 ppm), Chemical Formula CS2
DRAEGER Detector Tube;Ethylene;0.1 to 5 ppm;PK10
Detector Tube; Measurement Range 0.2 to 5 ppm; Gas Detected Ethylene; For Use With Draeger Accuro Pump; Color Change Pale Yellow to Grayish Blue; Operating Pressure 1;013 hPa; Operating Temperature - Minimum 50 Degrees F; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Shelf Life 2 yr; Application Civil Defense; Fire Brigades; Industrial Applications; Military; Includes Instructions; Sampling Time 30 min (0.2 to 5 ppm); Chemical Formula C2H4
DRAEGER Extension Hose;15 Meter;Accuro
Extension Hose; For Use With Draeger Accuro Pump; Product Type Extension Hose; Includes Adapter; Overall Length 49 ft; Material Neoprene; Rubber
DRAEGER Detector Tube;Ethylene;50to2500ppm;PK10
Detector Tube; Measurement Range 50 to 2500 ppm; Gas Detected Ethylene; For Use With Mfr. No. 6400000; Color Change Yellow to Blue; Operating Pressure 1;013 hPa; Operating Temperature - Minimum 59 Degrees F; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Shelf Life 2 yr; Application Civil Defense; Fire Brigades; Industrial Applications; Military; Includes Instructions; Sampling Time 6 min (50 to 2;500 ppm); Chemical Formula C2H4; CAS Number 74-85-1
DRAEGER Detector Tube;Toluene;50 to 400ppm;PK10
Detector Tube; Measurement Range 50 to 400 ppm; Gas Detected Toluene; For Use With Mfr. No. 6400000; Color Change White to Brown; Operating Pressure 1;013 hPa; Operating Temperature - Minimum 32 Degrees F; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Shelf Life 2 yr; Application Civil Defense; Fire Brigades; Industrial Applications; Military; Includes Instructions; Sampling Time 1.5 min (50 to 400 ppm); Chemical Formula C7H8; CAS Number 108-88-3
DRAEGER Detector Tube;Amines Qualitative;PK10
Detector Tube; Measurement Range Qualitative; Gas Detected Amines; For Use With Mfr. No. 6400000; Color Change Yellow to Blue; Operating Pressure 1;013 hPa; Operating Temperature - Minimum 32 Degrees F; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Shelf Life 2 yr; Application Civil Defense; Fire Brigades; Industrial Applications; Military; Includes Instructions; Sampling Time 5 sec; Operating Temperature - Maximum 104 Degrees F; Package Quantity 10
DRAEGER Gas Regulator
Gas Regulator
DRAEGER Detector Chip;Ethanol
Detector Chip; Measurement Range 100 to 2;500 ppm; Gas Detected Ethanol; For Use With CMS Analyzer; Operating Pressure 700 to 1;100 hPa; Operating Temperature - Minimum 50 Degrees F; Tube Material Plastic; Calibrated Yes; Product Type Detector Chip; Sampling Time 60 to 340 sec (100 to 2;500 ppm); Operating Temperature - Maximum 86 Degrees F
DRAEGER Multinational Power Supply 100/240 Vac (
Multinational Power Supply 100/240 Vac (
DRAEGER Detector Tube;Hydrochloric Acid;PK10
Detector Tube; Measurement Range 0.2 to 3 ppm/3 to 20 ppm; Gas Detected Hydrochloric Acid; For Use With Mfr. No. 6400000; Color Change Blue to Yellow; Operating Pressure 1;013 hPa; Operating Temperature - Minimum 41 Degrees F; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Shelf Life 2 yr; Application Civil Defense; Fire Brigades; Industrial Applications; Military; Includes Instructions; Sampling Time 2 m/0.4 min (0.2 to 3 ppm/3 to 20 ppm)
DRAEGER CMS Chip;Sulfur Dioxide;0.4-10 ppm
Detector Chip; Measurement Range 0.4 to10 ppm; Gas Detected Sulfur Dioxide; For Use With CMS Analyzer; Operating Pressure 700 to 1;100 hPa; Operating Temperature - Minimum 41 Degrees F; Tube Material Plastic; Calibrated Yes; Product Type Detector Chip; Application Industrial Applications; Sampling Time 40 to 300 sec (0.4 to 10 ppm); Chemical Formula SO2; CAS Number 7446-09-5; Operating Temperature - Maximum 86 Degrees F
DRAEGER Air Monitor Communication Module
Air Monitor Communication Module; Product Type Communication Module; Series 7000 Single-Gas; Communication Protocol USB; For Use With 7000 Single-Gas Detection Device; Includes USB Cable
DRAEGER Detector Tube;Acetone;40 to 800ppm;PK10
Detector Tube; Measurement Range 400 to 800 ppm; Gas Detected Acetone; For Use With Mfr. No. 6400000; Color Change Pale Yellow to Yellow; Operating Pressure 1;013 hPa; Operating Temperature - Minimum 41 Degrees F; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Shelf Life 2 yr; Application Civil Defense; Fire Brigades; Industrial Applications; Military; Includes Instructions; Sampling Time 1 min (400 to 800 ppm); Chemical Formula C3H6O; CAS Number 67-64-1
DRAEGER Gas Sensor;Hydrgn Peroxide;0 to 30.0 ppm
Gas Detector Sensor; Gas Detected Amines; Hydrides; Organic Vapors; Measurement Range 0 to 20 ppm; Compatible Detector Model/Series X-am; Sensor Type Electrochemical; Compatible Detector Manufacturer Part Number Pac III S/E; X-am 5100; Series X-AM; Resolution 0.1 ppm; Operating Temperature - Maximum 104 Degrees F; Operating Temperature - Minimum -4 Degrees F; Chemical Formula H2O2