Filters
Pipe Clamp Surface Probe, Product Type Pipe Clamp Probe, Maximum Operating Temperature Degrees F 536 Degrees F, Maximum Temperature Measured Degrees F 266 Degrees F, Minimum Operating Temperature Degrees F -76 Degrees F, Minimum Temperature Measured Degrees F -76 Degrees F, Maximum Dew Point Measured Not Applicable, Maximum Relative Humidity Measured Not Applicable, Minimum Dew Point Measured Not Applicable, Minimum Relative Humidity Measured Not Applicable, Compatible with Brand Testo Saveris
Thermocouple Probe, Not Applicable, Not Applicable, For Application Surface, Not Applicable, Fixed, Probe Size 7 in x 4 in x 1 in, Cable Length Not Applicable, -40 Degrees to 302 Degrees F /-40 Degrees to 150 Degrees C, Thermocouple, Thermowell Connection Clamp
Pressure Set, Maximum Pressure 40 in wc, Minimum Pressure 0 in wc, Accuracy +/-(0.00 in H2O + 1.50 Percent of mv) (0.40 to 40.00 in H2O), +/-0.01 in H2O (0.00 to 0.12 in H2O), +/-0.02 in H2O (0.12 to 0.40 in H2O), Batteries Included Yes, Digital Display Features Backlit Display, Series Testo 510, Application Water and VAC System, Auto Power Off Yes, Batteries Required Yes, Battery Type (2) AAA, Calibration Certificate Included No
Vacuum Gauge, Digital, Measuring Range 0 to 20,000 Microns, Ambient Operating Range (F) 14 Degrees to 122 Degrees , Connection 2 x 1/4 in SAE, Power Supply (2) AA Batteries, Includes Bluetooth Communication
Surface Probe for Wireless Handle, Type K, For Application Surface, Probe Size 6/32 in x 4.72 in, Thermocouple
CO2 Measuring Instrument, Calibration Certificate Type Available Separately, Digital Display Screen Type LED, Features In-App Configuration, Graph History, Long-Term Stable, Testo Smart App, Second Screen, Includes Calibration Protocol, Transport Bag, Maximum Carbon Dioxide Measured 10,000 ppm, Maximum Carbon Monoxide Measured Not Applicable, Maximum Dew Point Measured Not Applicable, Maximum Oxygen Measured Not Applicable, Maximum Pressure Measured Not Applicable
Manifold Gauge Set; Number of Valves 4
Air flow capture hood; 24 In. x 48 In. - for testo 420; Product Type Hood; Includes Integrated Flow Straightener for testo 420; Compatible with Series Testo 440; Compatible with Manufacturer Model Number 400563 4200; Overall Width 24 in; Overall Height 48 in
Digital Clamp Meter; Audible Continuity Yes; Safety Rating CAT III 1000V; CAT IV 600V; AC Response Calculation TRMS; Maximum AC Current Measurement 600 A; Maximum AC Voltage Measurement 1;000 V; Maximum DC Current Measurement 600 A; Maximum DC Voltage Measurement 600 V; Current Leakage Testing Yes; IP Rating IP40
Anemometer; Minimum Velocity Measured 78.7 fpm; Probe Type Rotating Vane; Maximum Velocity Measured 5;906 fpm; Minimum Dew Point Measured Not Applicable; Minimum Hot Wire Probe Length Not Applicable; Minimum Operating Temperature -4 Degrees F; Minimum Relative Humidity Measured Not Applicable; Includes Certificate of Conformity; Temperature Accuracy +/ 0.9 Degrees ; Wind Speed Units ft/min; km/hr; knot; m/sec; mph; Air Velocity Resolution 0.1 fpm; Maximum Operating Temperature 122 Degrees F
Manifold Gauge Kit; Number of Valves 4; Number of Hoses 4; 5 ft; EU Directive 2014/30/EU; Includes (2) Wireless Clamp Thermometers; Calibration Protocol; Carrying Case; Hose Filling Set; Vacuum Probe
L-type Pilot Tube; Accessory Type Pitot Tube; Type 13.8 in Pitot Tube; For Use With 0440 3351; 480; Manufacturers Warranty Length 2 yr
Smart Probe with Flexible Temperature Probe (TC Type K); Thermocouple; Number of Channels Not Applicable; Accuracy +/-0.4 Degrees F + 1 Percent of mv at 176 Degrees to 400 Degrees F; +/-1.3 Degrees F + 1 Percent of mv at -58 Degrees to -30 Degrees F; +/-1.8 Degrees F at -22 Degrees to 176 Degrees F; -58 Degrees to 752 Degrees F/-50 Degrees to 400 Degrees C; (3) AAA; Functions Low Battery Indication; Resolution 0.1 Degrees F
Digital Differential Pressure Measuring Instrument; Maximum Pressure 800 in wc; Minimum Pressure 0 in wc; Accuracy 0.50 Percent of Full Scale; Includes Batteries Yes; Process Connection Type Hose; Wireless Connectivity Bluetooth; Series Testo 512; Digital Display Features Display Graphical Measured Value Curve; Alarm Yes; Auto Power Off Yes; Batteries Required Yes; Battery Type (3) AA; Connection Material Silicone; Display Units in H2O
Replacement pH Electrode; Tip Shape Round; Body Material ABS; Cable Length 1.4 in; Amplifier No; For Use With pH/Temperature Measuring Instrument; Standards Not Applicable; Shelf Life Not Applicable; Junction Not Applicable
CO Probe; Compatible Product Type Air Velocity Meters; IAQ Meters; Product Type Digital Probe; Features Bluetooth Connection; Intelligent Calibration Concept; Long-Term Stable Electrochemical Sensor; Compatible with Grainger Part Number 818EK8; Compatible with Manufacturer Model Number 0560 0400; 0560 4402; Overall Height 7 7/8 in; Overall Length 2 in; Overall Width 1 5/8 in
Testo 420 - flow hood with soft case; Maximum Air Flow Measurement 2;354 cfm; Minimum Air Flow Measurement 29 cfm; Overall Height 37 in; Base Diameter 22 in; Differential Pressure +/-120 Pa; Hood Opening Length 2 ft; Hood Opening Width 2 ft; Includes Flow Straightener; Soft Case; Telescoping Handle; USB Cable; Wheels; Display Type Digital; Maximum Temperature Measured 140 Degrees F; Minimum Temperature Measured -4 Degrees F; Bluetooth Compatible Yes; Digital Display Screen Type LCD
Smart Case; Length 9 13/16 in; Application Instrument Carrying Case; For Use With Smart Probe Refrigeration set
Smart Probes AC Refrigeration Test Kit; Number of Valves 0; Multiple Refrigerants; Number of Hoses 0; 0 to 870 psi; -14 to 870 psi; +/-0.50 Percent; Brass; 350 ft. Bluetooth Range; Smart Probes APP Automatically Calculates Superheat; Subcooling; FCC ID: 2ACVD-1115; FCC ID: 2ACVD-1549; Includes Soft Carrying Case; Batteries; (2) 549i Refrigeration Smart Pressure Probes; (2) 115i Smart Probe Pipe-Clamp Thermometers
Smart Probes Bluetooth Connector (works with testo 115i; 510i; 915i); Product Type Bluetooth Connector; Gas Type Not Applicable; Compatible Product Type 300 Combustion Analyzers; Compatible with Manufacturer Model Number Testo 115i; Testo 510i; Testo 915i
One Hand Thermometer; Includes Battery; Standard Measurement Clip
Smart Case; Length 11 5/34 in; Application Instrument Carrying Case; For Use With Smart ProbeV AC Set
CO Probe; Compatible Product Type Air Velocity Meters; IAQ Meters; Product Type Digital Probe; Features Fixed Cable; Intelligent Calibration Concept; Long-Term Stable Electrochemical Sensor; Probe with a Practical Button on the Handle for Storing Individual CO Readings; Compatible with Grainger Part Number 818EK8; Compatible with Manufacturer Model Number 0560 0400; 0560 4402; Overall Height 7 7/8 in; Overall Length 2 in; Overall Width 1 5/8 in
Differential Manometer; Maximum Pressure 60 in wc; Minimum Pressure -60 in wc; Accuracy +/-(0.1 in wc + 1.5 Percent of mv) (0 to 60 in wc); +/-0.02 in wc (0 to 0.4 in wc); Includes Batteries Yes; Process Connection Size 1/8 in; 1/4 in; Process Connection Type Hose Barb; Wireless Connectivity Bluetooth; Alarm No; Application Air; Auto Power Off Yes; Batteries Required Yes; Battery Type (3) AAA; Calibration Certificate Included Yes; Compatible Smart Phones Android 4.3; Bluetooth 4.0; iOS 8.3
Penetration Probe for Air/Immersion; Type K; For Application Air; Probe Size 6/32 in x 3.94 in; Thermocouple
Globe Probe; Accessory Type Globe Probe; Type Probe; Includes 1.45 m Fixed Cable; For Use With 480; Manufacturers Warranty Length 2 yr