BRAND
-
BRAH ELECTRIC AC462RI, 60 amp, 600 volt, 3 phase
Bus Plug, Amps 60 A, Voltage 600V, 3 Phase, 4 Wire, For Use With GE Armor Clad Busway, Fusible Yes, Fuse Class H, J, R, Breaker Type AC; BEC, Height 12 7/10 in, Width 9 61/100 in, Depth 9 11/25 in, Standards UL Listed, UL Recognized
BRAH ELECTRIC Amp 60, 600 volt, 3 phase, 3 wire
Bus Plug, Amps 60 A, Voltage 600V, 3 Phase, 3 Wire with Ground, For Use With Type FVK, Fusible Yes, Fuse Class H, J, R, Breaker Type BEK; FVK, Height 11 3/10 in, Width 9 61/100 in, Depth 10 63/100 in
BRAH ELECTRIC AC363R, 100 amp, 600 volt, 3 phase
Bus Plug, Amps 100 A, Voltage 600V, 3 Phase, 3 Wire, For Use With GE Armor Clad Busway, Fusible Yes, Fuse Class H, J, R, Breaker Type AC; BEC, Height 16 7/10 in, Width 9 61/100 in, Depth 9 11/25 in, Standards UL Listed, UL Recognized
BRAH ELECTRIC Amp 100; 240 volt; 3 phase; 4 wire
Bus Plug; Amps 100 A; Voltage 240V; 3 Phase; 4 Wire; For Use With Eaton POW-R-WAY I and II Busway; Fusible Yes; Fuse Class R; Breaker Type BIP; Height 16 7/10 in; Width 9 61/100 in; Depth 9 41/100 in
BRAH ELECTRIC Amp 100, 240 volt, 3 phase, 3 wire
Bus Plug, Amps 100 A, Voltage 240V, 3 Phase, 3 Wire with Ground, For Use With Type FVK, Fusible Yes, Fuse Class H, J, R, Breaker Type BEK; FVK, Height 16 7/10 in, Width 9 3/5 in, Depth 10 63/100 in
BRAH ELECTRIC SB321RI, 30 amp, 240 volt, 3 phase
Bus Plug, Amps 30 A, Voltage 240V, 3 Phase, 3 Wire, For Use With GE Spectra Series Busway, Fusible Yes, Fuse Class H, J, R, Breaker Type BEB; SB, Height 11 19/50 in, Width 9 61/100 in, Depth 11 9/20 in, Standards UL Listed, UL Recognized
BRAH ELECTRIC SB462R, 60 amp, 600 volt, 3 phase
Bus Plug, Amps 60 A, Voltage 600V, 3 Phase, 4 Wire, For Use With GE Spectra Series Busway, Fusible Yes, Fuse Class H, J, R, Breaker Type BEB; SB, Height 9 61/100 in, Width 9 61/100 in, Depth 11 9/20 in, Standards UL Listed, UL Recognized
BRAH ELECTRIC Amp 60, 240 volt, 3 phase, 3 wire
Bus Plug, Amps 60 A, Voltage 240V, 3 Phase, 3 Wire, For Use With Siemens BD Busway, Fusible Yes, Fuse Class H, K, R, Breaker Type BES, Height 11 19/50 in, Width 9 61/100 in, Depth 9 49/50 in, Standards UL Listed, UL Recognized
BRAH ELECTRIC Amp 60, 240 volt, 3 phase, 4 wire
Bus Plug, Amps 60 A, Voltage 240V, 3 Phase, 4 Wire with Ground, For Use With Siemens BD Busway, Fusible Yes, Fuse Class H, K, R, Breaker Type BES, Height 11 19/50 in, Width 9 61/100 in, Depth 9 49/50 in, Standards UL Listed, UL Recognized
BRAH ELECTRIC Amp 30, 240 volt, 3 phase, 3 wire
Bus Plug, Amps 30 A, Voltage 240V, 3 Phase, 3 Wire with Ground, For Use With Siemens BD Busway, Fusible Yes, Fuse Class H, K, R, Breaker Type BES, Height 11 19/50 in, Width 9 61/100 in, Depth 9 49/50 in, Standards UL Listed, UL Recognized
BRAH ELECTRIC Amp 100, 600 volt, 3 phase, 3 wire
Bus Plug, Amps 100 A, Voltage 600V, 3 Phase, 3 Wire with Ground, For Use With Siemens Sentron Busway, Fusible Yes, Fuse Class H, J, R, Breaker Type BVB; SLID; SLVB; SLVBH; SXID
BRAH ELECTRIC BOS14353, 100 amp, 600 volt, 3 phase
Bus Plug, Amps 100 A, Voltage 600V, 3 Phase, 3 Wire, For Use With Siemens BD Busway, Fusible Yes, Fuse Class H, K, R, Breaker Type BES; BOS, Height 16 7/10 in, Width 9 61/100 in, Depth 10 49/50 in, Standards UL Listed, UL Recognized
BRAH ELECTRIC Amp 60, 240 volt, 3 phase, 4 wire
Bus Plug, Amps 60 A, Voltage 240V, 3 Phase, 4 Wire with Ground, For Use With Eaton POW-R-WAY III Busway, Fusible Yes, Fuse Class H, J, R, Breaker Type B3F; P3F
BRAH ELECTRIC FVK422; 60 amp; 240 volt; 3 phase
Bus Plug; Amps 60 A; Voltage 240V; 3 Phase; 4 Wire; For Use With Type FVK; Fusible Yes; Fuse Class H; J; R; Breaker Type BEK; FVK; Height 11 3/10 in; Width 9 61/100 in; Depth 10 63/100 in
BRAH ELECTRIC SL463RG, 100 amp, 600 volt, 3 phase
Bus Plug, Amps 100 A, Voltage 600V, 3 Phase, 4 Wire with Ground, For Use With GE Spectra Low-Amp Busway, Fusible Yes, Fuse Class H, J, R, Breaker Type BEL; SL, Height 16 7/10 in, Width 9 61/100 in, Depth 11 in, Standards UL Listed, UL Recognized
BRAH ELECTRIC P3F322, ITAP322R, 60 amp, 240 volt
Bus Plug, Amps 60 A, Voltage 240V, 3 Phase, 3 Wire, For Use With Eaton POW-R-WAY III Busway, Fusible Yes, Fuse Class H, J, R, Breaker Type B3F; P3F
BRAH ELECTRIC Amp 30, 240 volt, 3 phase, 4 wire
Bus Plug, Amps 30 A, Voltage 240V, 3 Phase, 4 Wire, For Use With Siemens Sentron Busway, Fusible Yes, Fuse Class H, J, R, Breaker Type BVB; SLID; SLVB; SLVBH; SXID
BRAH ELECTRIC AC322RI, 60 amp, 240 volt, 3 phase
Bus Plug, Amps 60 A, Voltage 240V, 3 Phase, 3 Wire, For Use With GE Armor Clad Busway, Fusible Yes, Fuse Class H, J, R, Breaker Type AC; BEC, Height 12 7/10 in, Width 9 61/100 in, Depth 9 11/25 in, Standards UL Listed, UL Recognized
BRAH ELECTRIC ITAP362; 60 amp; 600 volt; 3 phase
Bus Plug; Amps 60 A; Voltage 600V; 3 Phase; 3 Wire; For Use With Eaton POW-R-WAY I and II Busway; Fusible Yes; Fuse Class R; Breaker Type BIP; ITAP; Height 11 19/50 in; Width 9 61/100 in; Depth 9 41/100 in
BRAH ELECTRIC Amp 100, 600 volt, 3 phase, 3 wire
Bus Plug, Amps 100 A, Voltage 600V, 3 Phase, 3 Wire with Ground, For Use With Eaton POW-R-WAY I and II Busway, Fusible Yes, Fuse Class R, Breaker Type BIP, Height 16 7/10 in, Width 9 61/100 in, Depth 9 41/100 in
BRAH ELECTRIC P3F322GN, 60 amp, 240 volt, 3 phase
Bus Plug, Amps 60 A, Voltage 240V, 3 Phase, 4 Wire with Ground, For Use With Eaton POW-R-WAY III Busway, Fusible Yes, Fuse Class H, J, R, Breaker Type B3F; P3F
BRAH ELECTRIC ITAP361G, 30 amp, 600 volt, 3 phase
Bus Plug, Amps 30 A, Voltage 600V, 3 Phase, 3 Wire with Ground, For Use With Eaton POW-R-WAY I and II Busway, Fusible Yes, Fuse Class R, Breaker Type BIP; ITAP, Height 11 19/50 in, Width 9 61/100 in, Depth 9 41/100 in
BRAH ELECTRIC SB323RGI; 100 amp; 240 volt; 3 phase
Bus Plug; Amps 100 A; Voltage 240V; 3 Phase; 3 Wire with Ground; For Use With GE Spectra Series Busway; Fusible Yes; Fuse Class H; J; R; Breaker Type BEB; SB; Height 9 61/100 in; Width 9 61/100 in; Depth 11 47/100 in; Standards UL Listed; UL Recognized
BRAH ELECTRIC Amp 100; 600 volt; 3 phase; 4 wire
Bus Plug; Amps 100 A; Voltage 600V; 3 Phase; 4 Wire; For Use With Siemens Sentron Busway; Fusible Yes; Fuse Class H; J; R; Breaker Type BVB; SLID; SLVB; SLVBH; SXID
BRAH ELECTRIC AC421RI; 30 amp; 240 volt; 3 phase
Bus Plug; Amps 30 A; Voltage 240V; 3 Phase; 4 Wire; For Use With GE Armor Clad Busway; Fusible Yes; Fuse Class H; J; R; Breaker Type AC; BEC; Height 12 7/10 in; Width 9 61/100 in; Depth 9 11/25 in; Standards UL Listed; UL Recognized
BRAH ELECTRIC SL462RG; 60 amp; 600 volt; 3 phase
Bus Plug; Amps 60 A; Voltage 600V; 3 Phase; 4 Wire with Ground; For Use With GE Spectra Low-Amp Busway; Fusible Yes; Fuse Class H; J; R; Breaker Type BEL; SL; Height 11 19/50 in; Width 9 61/100 in; Depth 11 in; Standards UL Listed; UL Recognized
BRAH ELECTRIC BOS14322G; 60 amp; 240 volt
Bus Plug; Amps 60 A; Voltage 240V; 3 Phase; 3 Wire with Ground; For Use With Siemens BD Busway; Fusible Yes; Fuse Class H; K; R; Breaker Type BES; BOS; Height 11 19/50 in; Width 9 61/100 in; Depth 9 49/50 in; Standards UL Listed; UL Recognized
BRAH ELECTRIC Amp 30; 600 volt; 3 phase; 3 wire
Bus Plug; Amps 30 A; Voltage 600V; 3 Phase; 3 Wire; For Use With Siemens Sentron Busway; Fusible Yes; Fuse Class H; J; R; Breaker Type BVB; SLID; SLVB; SLVBH; SXID
BRAH ELECTRIC Amp 30; 240 volt; 3 phase; 4 wire
Bus Plug; Amps 30 A; Voltage 240V; 3 Phase; 4 Wire with Ground; For Use With Eaton POW-R-WAY III Busway; Fusible Yes; Fuse Class H; J; R; Breaker Type B3F; P3F
BRAH ELECTRIC SB362R; 60 amp; 600 volt; 3 phase
Bus Plug; Amps 60 A; Voltage 600V; 3 Phase; 3 Wire; For Use With GE Spectra Series Busway; Fusible Yes; Fuse Class H; J; R; Breaker Type BEB; SB; Height 11 19/50 in; Width 9 61/100 in; Depth 11 9/20 in; Standards UL Listed; UL Recognized