HEDLAND Flowmeter, 0.5-5.0 / 2-19 GPM/LPM
Mechanical Flowmeter, Product Type Petroleum Fluid Meter, Flowmeter Type Variable Area, Accuracy +/-2 Percent, Connection Size 1/2 in, Connection Type SAE, Compatible Flow Material Petroleum Fluids, Media Temperature - Maximum 240 Degrees F, Media Temperature - Minimum -20 Degrees F, Viscosity - Maximum 500 SUS, Voltage - Maximum Not Applicable, Housing Material Aluminum, Rotor Material Not Applicable, O-Ring Material Viton, Seal Material Viton, Shaft Material Not Applicable
HEDLAND Flowmeter,GPM/LPM  0.2 - 2.0 / 1-7.5
Mechanical Flowmeter, Product Type Water and Other Fluid Meter, Flowmeter Type Variable Area, Accuracy +/-7 Percent, Connection Size 1/4 in, Connection Type NPTF, Compatible Flow Material Water, Media Temperature - Maximum 240 Degrees F, Media Temperature - Minimum -20 Degrees F, Viscosity - Maximum 500 SUS, Voltage - Maximum Not Applicable, Housing Material Brass, Rotor Material Not Applicable, O-Ring Material Viton, Seal Material Viton, Shaft Material Not Applicable, Wetted Material Brass
HEDLAND Flowmeter,2 FNPT, 10-100 GPM
Mechanical Flowmeter, Product Type Flow Meter, Flowmeter Type Variable Area, Accuracy +/-5 Percent, Connection Size 2 in, Connection Type NPTF, Compatible Flow Material Water, Media Temperature - Maximum 250 Degrees F, Media Temperature - Minimum 32 Degrees F, Viscosity - Maximum 500 SUS, Voltage - Maximum Not Applicable, Housing Material PPSU, Rotor Material Not Applicable, O-Ring Material Buna-N, Seal Material Buna-N, Shaft Material Not Applicable, Wetted Material PSU
HEDLAND Flowmeter, 1/2 FNPT, 1-16 GPM
Mechanical Flowmeter, Product Type Flow Meter, Flowmeter Type Variable Area, Accuracy +/-5 Percent, Connection Size 1/2 in, Connection Type NPTF, Compatible Flow Material Water, Media Temperature - Maximum 250 Degrees F, Media Temperature - Minimum 32 Degrees F, Viscosity - Maximum 500 SUS, Voltage - Maximum Not Applicable, Housing Material PPSU, Rotor Material Not Applicable, O-Ring Material Buna-N, Seal Material Buna-N, Shaft Material Not Applicable, Wetted Material PSU
HEDLAND Flowmeter,GPM/LPM  1.0 - 10 / 5-38
Mechanical Flowmeter, Product Type Petroleum Fluid Meter, Flowmeter Type Variable Area, Accuracy +/-2 Percent, Connection Size 1 in, Connection Type NPTF, Compatible Flow Material Petroleum Fluids, Media Temperature - Maximum 240 Degrees F, Media Temperature - Minimum -20 Degrees F, Viscosity - Maximum 500 SUS, Voltage - Maximum Not Applicable, Housing Material Aluminum, Rotor Material Not Applicable, O-Ring Material Viton, Seal Material Viton, Shaft Material Not Applicable
HEDLAND Flowmeter,SCFM / L/SEC 10 - 100 / 5-47
Mechanical Flowmeter, Product Type Air and Compressed Gas Meter, Flowmeter Type Variable Area, Accuracy +/-2 Percent, Connection Size 1/2 in, Connection Type NPTF, Compatible Flow Material Air, Compressed Gases, Media Temperature - Maximum 240 Degrees F, Media Temperature - Minimum -20 Degrees F, Viscosity - Maximum 500 SUS, Voltage - Maximum Not Applicable, Housing Material Aluminum, Rotor Material Not Applicable, O-Ring Material Viton, Seal Material Viton, Shaft Material Not Applicable
HEDLAND Flowmeter,GPM/LPM  1.0 - 10 / 5-38
Mechanical Flowmeter, Product Type Water and Other Fluid Meter, Flowmeter Type Variable Area, Accuracy +/-2 Percent, Connection Size 1/2 in, Connection Type NPTF, Compatible Flow Material Water, Media Temperature - Maximum 240 Degrees F, Media Temperature - Minimum -20 Degrees F, Viscosity - Maximum 500 SUS, Voltage - Maximum Not Applicable, Housing Material Brass, Rotor Material Not Applicable, O-Ring Material Viton, Seal Material Viton, Shaft Material Not Applicable, Wetted Material Brass
HEDLAND Flowmeter, 2 FNPT, 5-50 GPM
Mechanical Flowmeter, Product Type Flow Meter, Flowmeter Type Variable Area, Accuracy +/-5 Percent, Connection Size 2 in, Connection Type NPTF, Compatible Flow Material Water, Media Temperature - Maximum 250 Degrees F, Media Temperature - Minimum 32 Degrees F, Viscosity - Maximum 500 SUS, Voltage - Maximum Not Applicable, Housing Material PPSU, Rotor Material Not Applicable, O-Ring Material Buna-N, Seal Material Buna-N, Shaft Material Not Applicable, Wetted Material PSU
HEDLAND Flowmeter, 1 MNPT, 4-28 GPM
Mechanical Flowmeter, Product Type Flow Meter, Flowmeter Type Variable Area, Accuracy +/-5 Percent, Connection Size 1 in, Connection Type NPTF, Compatible Flow Material Water, Media Temperature - Maximum 250 Degrees F, Media Temperature - Minimum 32 Degrees F, Viscosity - Maximum 500 SUS, Voltage - Maximum Not Applicable, Housing Material PPSU, Rotor Material Not Applicable, O-Ring Material Buna-N, Seal Material Buna-N, Shaft Material Not Applicable, Wetted Material PSU
HEDLAND Flowmeter,GPM/LPM  10 - 100 / 50-380
Mechanical Flowmeter, Product Type Petroleum Fluid Meter, Flowmeter Type Variable Area, Accuracy +/-2 Percent, Connection Size 1 1/4 in, Connection Type SAE, Compatible Flow Material Petroleum Fluids, Media Temperature - Maximum 240 Degrees F, Media Temperature - Minimum -20 Degrees F, Viscosity - Maximum 500 SUS, Voltage - Maximum Not Applicable, Housing Material Aluminum, Rotor Material Not Applicable, O-Ring Material Viton, Seal Material Viton, Shaft Material Not Applicable
HEDLAND Flowmeter,GPM/LPM  0.5 - 5.0 / 2-19
Mechanical Flowmeter, Product Type Water and Other Fluid Meter, Flowmeter Type Variable Area, Accuracy +/-2 Percent, Connection Size 3/4 in, Connection Type NPTF, Compatible Flow Material Water, Media Temperature - Maximum 240 Degrees F, Media Temperature - Minimum -20 Degrees F, Viscosity - Maximum 500 SUS, Voltage - Maximum Not Applicable, Housing Material Brass, Rotor Material Not Applicable, O-Ring Material Viton, Seal Material Viton, Shaft Material Not Applicable, Wetted Material Brass
HEDLAND Flow Switch, AC Latching
Flow Switch, Connection Type NPT, Contact Rating (AC) 0.5 A @ 125V, Contact Rating (DC) 1 A @ 30V, Flow Switch Type Paddle, Frequency 50 Hz, 60 Hz, Housing Material Polycarbonate, Media Temperature - Maximum 158 Degrees F, Media Temperature - Minimum 32 Degrees F, Set Point Configuration Adjustable, Switch Enclosure NEMA 12, NEMA 13, Switch Position Normally Open
HEDLAND Flowmeter,GPM/LPM  1.0 - 10  / 4-35
Mechanical Flowmeter, Product Type Flow Meter, Flowmeter Type Variable Area, Accuracy +/-5 Percent, Connection Size 3/4 in, Connection Type NPTF, Compatible Flow Material Water, Media Temperature - Maximum 250 Degrees F, Media Temperature - Minimum 32 Degrees F, Viscosity - Maximum 500 SUS, Voltage - Maximum Not Applicable, Housing Material PSU, Rotor Material Not Applicable, O-Ring Material Buna-N, Seal Material Buna-N, Shaft Material Not Applicable, Wetted Material PSU
HEDLAND Flowmeter,GPM/LPM  1.0 - 10 / 4-35
Mechanical Flowmeter, Product Type Flow Meter, Flowmeter Type Variable Area, Accuracy +/-5 Percent, Connection Size 1/2 in, Connection Type NPTF, Compatible Flow Material Water, Media Temperature - Maximum 250 Degrees F, Media Temperature - Minimum 32 Degrees F, Viscosity - Maximum 500 SUS, Voltage - Maximum Not Applicable, Housing Material PSU, Rotor Material Not Applicable, O-Ring Material Buna-N, Seal Material Buna-N, Shaft Material Not Applicable, Wetted Material PSU
HEDLAND Flowmeter,GPM/LPM  2.0 - 20 / 10-76
Mechanical Flowmeter, Product Type Water and Other Fluid Meter, Flowmeter Type Variable Area, Accuracy +/-2 Percent, Connection Size 1 in, Connection Type NPTF, Compatible Flow Material Water, Media Temperature - Maximum 240 Degrees F, Media Temperature - Minimum -20 Degrees F, Viscosity - Maximum 500 SUS, Voltage - Maximum Not Applicable, Housing Material Stainless Steel, Rotor Material Not Applicable, O-Ring Material Viton, Seal Material Viton, Shaft Material Not Applicable
HEDLAND Flowmeter;GPM/LPM  10 - 150 / 50-560
Mechanical Flowmeter; Product Type Petroleum Fluid Meter; Flowmeter Type Variable Area; Accuracy +/-2 Percent; Connection Size 1 1/4 in; Connection Type NPTF; Compatible Flow Material Petroleum Fluids; Media Temperature - Maximum 240 Degrees F; Media Temperature - Minimum -20 Degrees F; Viscosity - Maximum 500 SUS; Voltage - Maximum Not Applicable; Housing Material Aluminum; Rotor Material Not Applicable; O-Ring Material Viton; Seal Material Viton; Shaft Material Not Applicable
HEDLAND Flowmeter;3/4 Sweat;1-16 GPM
Mechanical Flowmeter; Product Type Flow Meter; Flowmeter Type Variable Area; Accuracy +/-5 Percent; Connection Size 1 in; Connection Type Sweat; Compatible Flow Material Water; Media Temperature - Maximum 250 Degrees F; Media Temperature - Minimum 32 Degrees F; Viscosity - Maximum 500 SUS; Voltage - Maximum Not Applicable; Housing Material PPSU; Rotor Material Not Applicable; O-Ring Material Buna-N; Seal Material Buna-N; Shaft Material Not Applicable; Wetted Material PSU
HEDLAND Flowmeter;GPM/LPM  0.5 - 5.0 / 2-19
Flow Switch; Connection Size 1/2 in; Connection Type FNPT; Contact Rating (AC) 10 A @ 250V; Contact Rating (DC) 0.5 A @ 125V DC; Flow Rate - Maximum 5 gpm; Flow Rate - Minimum 0.5 gpm; Flow Switch Type Piston; For Pipe Size 1/2 in; Housing Material Aluminum; Media Temperature - Maximum 240 Degrees F; Media Temperature - Minimum -20 Degrees F; Set Point Configuration Adjustable; Standards -; Switch Enclosure NEMA 12; NEMA 13; Switch Position Normally Closed; Normally Open; Switch Type SPDT
HEDLAND Flowmeter; 1 MNPT; 0.5-4 GPM
Mechanical Flowmeter; Product Type Flow Meter; Flowmeter Type Variable Area; Accuracy +/-5 Percent; Connection Size 1 in; Connection Type NPTF; Compatible Flow Material Water; Media Temperature - Maximum 250 Degrees F; Media Temperature - Minimum 32 Degrees F; Viscosity - Maximum 500 SUS; Voltage - Maximum Not Applicable; Housing Material PPSU; Rotor Material Not Applicable; O-Ring Material Buna-N; Seal Material Buna-N; Shaft Material Not Applicable; Wetted Material PSU
HEDLAND Flowmeter; 1/2 FNPT; 0.5-4 GPM
Mechanical Flowmeter; Product Type Flow Meter; Flowmeter Type Variable Area; Accuracy +/-5 Percent; Connection Size 1/2 in; Connection Type NPTF; Compatible Flow Material Water; Media Temperature - Maximum 250 Degrees F; Media Temperature - Minimum 32 Degrees F; Viscosity - Maximum 500 SUS; Voltage - Maximum Not Applicable; Housing Material PPSU; Rotor Material Not Applicable; O-Ring Material Buna-N; Seal Material Buna-N; Shaft Material Not Applicable; Wetted Material PSU
HEDLAND Flowmeter;GPM/LPM  0.5 - 5.0 / 2-19
Mechanical Flowmeter; Product Type High Temperature Flow Meter; Flowmeter Type Variable Area; Accuracy +/-2 Percent; Connection Size 1/2 in; Connection Type NPTF; Compatible Flow Material Petroleum Fluids; Media Temperature - Maximum 400 Degrees F; Media Temperature - Minimum -20 Degrees F; Viscosity - Maximum 500 SUS; Voltage - Maximum Not Applicable; Housing Material Aluminum; Rotor Material Not Applicable; O-Ring Material Viton; Seal Material Viton; Shaft Material Not Applicable
HEDLAND Flowmeter;GPM/LPM  2.0 - 20 / 10-76
Mechanical Flowmeter; Product Type Petroleum Fluid Meter; Flowmeter Type Variable Area; Accuracy +/-2 Percent; Connection Size 3/4 in; Connection Type NPTF; Compatible Flow Material Petroleum Fluids; Media Temperature - Maximum 240 Degrees F; Media Temperature - Minimum -20 Degrees F; Viscosity - Maximum 500 SUS; Voltage - Maximum Not Applicable; Housing Material Aluminum; Rotor Material Not Applicable; O-Ring Material Viton; Seal Material Viton; Shaft Material Not Applicable
HEDLAND Flowmeter; 1 SOC; 0.5-4 GPM
Mechanical Flowmeter; Product Type Flow Meter; Flowmeter Type Variable Area; Accuracy +/-5 Percent; Connection Size 1 in; Connection Type Socket; Compatible Flow Material Water; Media Temperature - Maximum 250 Degrees F; Media Temperature - Minimum 32 Degrees F; Viscosity - Maximum 500 SUS; Voltage - Maximum Not Applicable; Housing Material PPSU; Rotor Material Not Applicable; O-Ring Material Buna-N; Seal Material Buna-N; Shaft Material Not Applicable; Wetted Material PSU
HEDLAND Flowmeter;GPM/LPM  2.0 - 20 / 10-76
Mechanical Flowmeter; Product Type Petroleum Fluid Meter; Flowmeter Type Variable Area; Accuracy +/-2 Percent; Connection Size 1 in; Connection Type SAE; Compatible Flow Material Petroleum Fluids; Media Temperature - Maximum 240 Degrees F; Media Temperature - Minimum -20 Degrees F; Viscosity - Maximum 500 SUS; Voltage - Maximum Not Applicable; Housing Material Aluminum; Rotor Material Not Applicable; O-Ring Material Viton; Seal Material Viton; Shaft Material Not Applicable
HEDLAND Flowmeter; 2 SOC; 5-50 GPM
Mechanical Flowmeter; Product Type Flow Meter; Flowmeter Type Variable Area; Accuracy +/-5 Percent; Connection Size 2 in; Connection Type Socket; Compatible Flow Material Water; Media Temperature - Maximum 250 Degrees F; Media Temperature - Minimum 32 Degrees F; Viscosity - Maximum 500 SUS; Voltage - Maximum Not Applicable; Housing Material PPSU; Rotor Material Not Applicable; O-Ring Material Buna-N; Seal Material Buna-N; Shaft Material Not Applicable; Wetted Material PSU
HEDLAND Flowmeter; 3/4 MNPT; 1-7 GPM
Mechanical Flowmeter; Product Type Flow Meter; Flowmeter Type Variable Area; Accuracy +/-5 Percent; Connection Size 3/4 in; Connection Type NPTF; Compatible Flow Material Water; Media Temperature - Maximum 250 Degrees F; Media Temperature - Minimum 32 Degrees F; Viscosity - Maximum 500 SUS; Voltage - Maximum Not Applicable; Housing Material PPSU; Rotor Material Not Applicable; O-Ring Material Buna-N; Seal Material Buna-N; Shaft Material Not Applicable; Wetted Material PSU
HEDLAND Flowmeter;GPM/LPM  1.0 - 10 / 5-38
Mechanical Flowmeter; Product Type Petroleum Fluid Meter; Flowmeter Type Variable Area; Accuracy +/-2 Percent; Connection Size 3/4 in; Connection Type NPTF; Compatible Flow Material Petroleum Fluids; Media Temperature - Maximum 240 Degrees F; Media Temperature - Minimum -20 Degrees F; Viscosity - Maximum 500 SUS; Voltage - Maximum Not Applicable; Housing Material Aluminum; Rotor Material Not Applicable; O-Ring Material Viton; Seal Material Viton; Shaft Material Not Applicable
HEDLAND Flowmeter;3/4 MNPT; 1-16 GPM
Mechanical Flowmeter; Product Type Flow Meter; Flowmeter Type Variable Area; Accuracy +/-5 Percent; Connection Size 3/4 in; Connection Type NPTF; Compatible Flow Material Water; Media Temperature - Maximum 250 Degrees F; Media Temperature - Minimum 32 Degrees F; Viscosity - Maximum 500 SUS; Voltage - Maximum Not Applicable; Housing Material PPSU; Rotor Material Not Applicable; O-Ring Material Buna-N; Seal Material Buna-N; Shaft Material Not Applicable; Wetted Material PSU
HEDLAND Flowmeter;SCFM / L/SEC 25 - 250 / 10-118
Mechanical Flowmeter; Product Type Air and Compressed Gas Meter; Flowmeter Type Variable Area; Accuracy +/-2 Percent; Connection Size 3/4 in; Connection Type NPTF; Compatible Flow Material Air; Compressed Gases; Media Temperature - Maximum 240 Degrees F; Media Temperature - Minimum -20 Degrees F; Viscosity - Maximum 500 SUS; Voltage - Maximum Not Applicable; Housing Material Aluminum; Rotor Material Not Applicable; O-Ring Material Viton; Seal Material Viton; Shaft Material Not Applicable
HEDLAND Flowmeter; 1 SOC; 3-18 GPM
Mechanical Flowmeter; Product Type Flow Meter; Flowmeter Type Variable Area; Accuracy +/-5 Percent; Connection Size 1 in; Connection Type Socket; Compatible Flow Material Water; Media Temperature - Maximum 250 Degrees F; Media Temperature - Minimum 32 Degrees F; Viscosity - Maximum 500 SUS; Voltage - Maximum Not Applicable; Housing Material PPSU; Rotor Material Not Applicable; O-Ring Material Buna-N; Seal Material Buna-N; Shaft Material Not Applicable; Wetted Material PSU