Solenoid, AC Laminate Pull Type, Stroke Range 0 to 1 in, Pull Force Range 64.0 to 256.0 oz, Width 2 1/2 in, Depth 1 203/250 in, Length 2 3/50 in, Coil Volts 240 V AC, Seated Amps 0.22 A, Seated Watts 17.5 W, Coil Resistance 82 ohms, Coil Insulation Class 155; Class F, Terminals 1/4 in QC, Amps @ Max. Stroke 2.5 A, Duty Cycle Continuous, Max. On Time 180 sec, Material of Construction Steel, Mounting Holes (4) slots, Ø.208 x .250, 21/100 in From Mounting Holes to Plunger Hole, Standards RoHS, UL
LEDEX Solenoid
Solenoid; AC Laminate Pull Type; Stroke Range 0 to 1 in; Pull Force Range 96.0 to 256.0 oz; Width 2 1/2 in; Depth 2 31/500 in; Length 2 3/50 in; Coil Volts 240V AC; Seated Amps 0.24 A; Seated Watts 18 W; Coil Resistance 60 ohms; Coil Insulation Class 155; Class F; Terminals 1/4 in QC; Amps @ Max. Stroke 3.2 A; Duty Cycle Continuous; Max. On Time 180 sec; Material of Construction Steel; Mounting Holes (4) slots; Ø.208 x .250; 433/1000 in From Mounting Holes to Plunger Hole; Standards RoHS; UL
LEDEX Solenoid
Solenoid; AC Laminate Pull Type; Stroke Range 0 to 1 in; Pull Force Range 96.0 to 256.0 oz; Width 2 1/2 in; Depth 2 31/500 in; Length 2 3/50 in; Coil Volts 120V AC; Seated Amps 0.48 A; Seated Watts 19 W; Coil Resistance 14.8 ohms; Coil Insulation Class 155; Class F; Terminals 1/4 in QC; Amps @ Max. Stroke 6.8 A; Duty Cycle Continuous; Max. On Time 180 sec; Material of Construction Steel; Mounting Holes (4) slots; Ø.208 x .250; 433/1000 in From Mounting Holes to Plunger Hole; Standards RoHS; UL
LEDEX Solenoid
Solenoid; AC Box Frame Pull Type; Stroke Range 0 to 1 in; Pull Force Range 48.0 to 288.0 oz; Width 1 9/20 in; Depth 1 63/100 in; Length 2 9/50 in; Coil Volts 240 V AC; Seated Amps 0.58 A; Coil Resistance 78 ohms; Coil Insulation 105C max; Class A; Terminals 3/16 in QC; Amps @ Max. Stroke 2.119 A; Duty Cycle Intermittent; Max. On Time 180 sec; Material of Construction Steel; Mounting Holes 8x #8-32 UNC; 2 3/25 in From Mounting Holes to Plunger Hole; Standards RoHS
LEDEX Solenoid
Solenoid; AC Box Frame Pull Type; Stroke Range 0 to 1 in; Pull Force Range 16.0 to 88.0 oz; Width 1 31/100 in; Depth 1 47/100 in; Length 1 61/100 in; Coil Volts 120V AC; Seated Amps 0.162 A; Coil Resistance 107.0 ohms; Coil Insulation 105C max; Class A; Terminals 3/16 in QC; Amps @ Max. Stroke 0.925 A; Duty Cycle Continuous; Max. On Time 180 sec; Material of Construction Steel; Mounting Holes 2x #10-32 UNF; 169/200 in From Mounting Holes to Plunger Hole; Standards RoHS
LEDEX Solenoid
Solenoid; AC Laminate Pull Type; Stroke Range 0 to 1 in; Pull Force Range 64.0 to 256.0 oz; Width 2 1/2 in; Depth 1 203/250 in; Length 2 3/50 in; Coil Volts 240V AC; Seated Amps 0.32 A; Seated Watts 23.8 W; Coil Resistance 73.5 ohms; Coil Insulation Class 155; Class F; Terminals 1/4 in QC; Amps @ Max. Stroke 2.9 A; Duty Cycle Intermittent; Max. On Time 180 sec; Material of Construction Steel; Mounting Holes (4) slots; Ø.208 x .250; 437/1000 in From Mounting Holes to Plunger Hole; Standards RoHS
LEDEX Solenoid
Solenoid; AC Laminate Pull Type; Stroke Range 0 to 0.75 in; Pull Force Range 16.0 to 128.0 oz; Width 1 609/1000 in; Depth 1 427/1000 in; Length 1 219/500 in; Coil Volts 240 V AC; Seated Amps 0.26 A; Seated Watts 19.5 W; Coil Resistance 161 ohms; Coil Insulation Class 105; Class A; Terminals Solder Lug Coil; Amps @ Max. Stroke 1.4 A; Duty Cycle Intermittent; Max. On Time 180 sec; Material of Construction Steel; Mounting Holes 4x Ø.156 thru; 107/200 in From Mounting Holes to Plunger Hole
LEDEX Solenoid
Solenoid; AC Laminate Pull Type; Stroke Range 0 to 0.75 in; Pull Force Range 16.0 to 128.0 oz; Width 1 609/1000 in; Depth 1 427/1000 in; Length 1 219/500 in; Coil Volts 240 V AC; Seated Amps 0.13 A; Seated Watts 9 W; Coil Resistance 258 ohms; Coil Insulation Class 105; Class A; Terminals Solder Lug Coil; Amps @ Max. Stroke 0.78 A; Duty Cycle Continuous; Max. On Time 180 sec; Material of Construction Steel; Mounting Holes 4x Ø.156 thru; 107/200 in From Mounting Holes to Plunger Hole
LEDEX Solenoid
Solenoid; AC Laminate Pull Type; Stroke Range 0 to 0.75 in; Pull Force Range 24.0 to 128 oz; Width 1 609/1000 in; Depth 1 47/250 in; Length 1 219/500 in; Coil Volts 240 V AC; Seated Amps 0.24 A; Seated Watts 18.5 W; Coil Resistance 240 ohms; Coil Insulation Class 105; Class A; Terminals Solder Lug Coil; Amps @ Max. Stroke 0.84 A; Duty Cycle Intermittent; Max. On Time 180 sec; Material of Construction Steel; Mounting Holes 4x Ø.156 thru; 107/200 in From Mounting Holes to Plunger Hole
LEDEX Solenoid
Solenoid; AC Laminate Pull Type; Stroke Range 0 to 0.75 in; Pull Force Range 24.0 to 128 oz; Width 1 609/1000 in; Depth 1 47/250 in; Length 1 219/500 in; Coil Volts 120 V AC; Seated Amps 0.52 A; Seated Watts 20 W; Coil Resistance 58 ohms; Coil Insulation Class 105; Class A; Terminals Solder Lug Coil; Amps @ Max. Stroke 1.9 A; Duty Cycle Intermittent; Max. On Time 180 sec; Material of Construction Steel; Mounting Holes 4x Ø.156 thru; 107/200 in From Mounting Holes to Plunger Hole
LEDEX Solenoid
Solenoid; AC Laminate Pull Type; Stroke Range 0 to 1 in; Pull Force Range 128.0 to 512.0 oz; Width 2 1/2 in; Depth 2 31/500 in; Length 2 3/50 in; Coil Volts 240V AC; Seated Amps 0.48 A; Seated Watts 36 W; Coil Resistance 48 ohms; Coil Insulation Class 155; Class F; Terminals 1/4 in QC; Amps @ Max. Stroke 4.3 A; Duty Cycle Intermittent; Max. On Time 180 sec; Material of Construction Steel; Mounting Holes (4) slots; Ø.208 x .250; 433/1000 in From Mounting Holes to Plunger Hole; Standards RoHS
LEDEX Solenoid
Solenoid; AC Box Frame Pull Type; Stroke Range 0 to 1 in; Pull Force Range 14.0 to 80.0 oz; Width 1 9/20 in; Depth 1 63/100 in; Length 2 9/50 in; Coil Volts 240 V AC; Seated Amps 0.075 A; Coil Resistance 320 ohms; Coil Insulation 105C max; Class A; Terminals 3/16 in QC; Amps @ Max. Stroke 0.558 A; Duty Cycle Continuous; Material of Construction Steel; Mounting Holes 8x #8-32 UNC; 2 3/25 in From Mounting Holes to Plunger Hole; Standards RoHS
LEDEX Solenoid
Solenoid; AC Laminate Pull Type; Stroke Range 0 to 1 in; Pull Force Range 128.0 to 512.0 oz; Width 2 1/2 in; Depth 2 31/500 in; Length 2 3/50 in; Coil Volts 120V AC; Seated Amps 0.95 A; Seated Watts 36.5 W; Coil Resistance 11.7 ohms; Coil Insulation Class 155; Class F; Terminals 1/4 in QC; Amps @ Max. Stroke 8.5 A; Duty Cycle Intermittent; Max. On Time 180 sec; Material of Construction Steel; Mounting Holes (4) slots; Ø.208 x .250; 433/1000 in From Mounting Holes to Plunger Hole; Standards RoHS
LEDEX Solenoid
Solenoid; AC Box Frame Pull Type; Stroke Range 0 to 1 in; Pull Force Range 32.0 to 192.0 oz; Width 1 31/100 in; Depth 1 47/100 in; Length 1 61/100 in; Coil Volts 240 V AC; Seated Amps 0.357 A; Coil Resistance 163 ohms; Coil Insulation 105C max; Class A; Terminals 3/16 in QC; Amps @ Max. Stroke 1.283 A; Duty Cycle Intermittent; Max. On Time 180 sec; Material of Construction Steel; Mounting Holes 2x #10-32 UNF; 169/200 in From Mounting Holes to Plunger Hole; Standards RoHS
LEDEX Solenoid
Solenoid; AC C-Frame Pull Type; Stroke Range 0 to 1/2 in; Pull Force Range 3.2 to 56 oz; Width 3/4 in; Depth 81/100 in; Length 1 13/100 in; Coil Volts 240 V AC; Seated Amps 0.056 A; Coil Resistance 2010 ohms; Coil Insulation 105C max; Class A; Terminals 3/16 in QC; Amps @ Max. Stroke 0.112 A; Duty Cycle Intermittent; Max. On Time 180 sec; Material of Construction Steel; Mounting Holes 2x #6-32 UNC; 3/4 in From Mounting Holes to Plunger Hole; Standards RoHS
LEDEX Solenoid
Solenoid; AC C-Frame Pull Type; Stroke Range 0 to 1/2 in; Pull Force Range 3.2 to 56 oz; Width 3/4 in; Depth 81/100 in; Length 1 13/100 in; Coil Volts 120 V AC; Seated Amps 0.112 A; Coil Resistance 500 ohms; Coil Insulation 105C max; Class A; Terminals 3/16 in QC; Amps @ Max. Stroke 0.146 A; Duty Cycle Intermittent; Max. On Time 180 sec; Material of Construction Steel; Mounting Holes 2x #6-32 UNC; 3/4 in From Mounting Holes to Plunger Hole; Standards RoHS