Filters
Replacement Motor Brush Set, For Use With Mfr. No. 115330, Mfr. No. 115334, Mfr. No. 115937, Mfr. No. 115962, Mfr. No. 116103-00, Mfr. No. 116118-00, Mfr. No. 116119-00, Mfr. No. 116161-00, Package Quantity 2
Replacement Motor Brush Set, For Use With Mfr. No. 119433-13, Mfr. No. 119436-13, Package Quantity 2
Vacuum Motor, Single Phase, Motor Design Universal AC/DC, Nameplate RPM 22,275, No. of Speeds 1, 120V AC Voltage, Full Load Amps 10.7, Non-Standard Frame, Motor/Blower Type Bypass, Max. Amps 6.8 A, 60/50 Hz, Motor Thermal Protection None, Ins. Class A, Max. Ambient Temp. 40 Degrees C, Duty Cycle Intermittent, Motor Enclosure Design Open, Motor Mounting Type Lug, Motor Mounting Position All Angle, Max. Air Watts 382 W, Vacuum Rating 119.6, CFM @ 2-In. Orifice 100 cfm
Vacuum Motor, Single Phase, Motor Design Universal AC/DC, Nameplate RPM 20,891, No. of Speeds 1, 240V AC Voltage, Full Load Amps 6.9, Motor/Blower Type Bypass, Max. Amps 7 A, 60/50 Hz, Motor Thermal Protection None, Ins. Class A, Max. Ambient Temp. 40 Degrees C, Duty Cycle Intermittent, Motor Enclosure Design Open, Motor Mounting Type Lug, Motor Mounting Position All Angle, Max. Air Watts 404 W, Vacuum Rating 129, CFM @ 2-In. Orifice 97.3 cfm, Mounting Bracket Material Aluminum
Vacuum Motor, Single Phase, Motor Design Universal AC/DC, Nameplate RPM 24,850, No. of Speeds 1, 240V AC Voltage, Full Load Amps 4.6, Non-Standard Frame, Motor/Blower Type Bypass, Max. Amps 3 A, 60/50 Hz, Motor Thermal Protection None, Ins. Class A, Max. Ambient Temp. 40 Degrees C, Duty Cycle Intermittent, Motor Enclosure Design Open, Motor Mounting Type Lug, Motor Mounting Position All Angle, Max. Air Watts 349 W, Vacuum Rating 94.2, CFM @ 2-In. Orifice 110.5 cfm, Motor Bearings Ball
Replacement Motor Brush Set, For Use With Mfr. No. 119401-00, Mfr. No. 119403-00, Package Quantity 2
Universal AC/DC Motor, Single Phase, Motor Design Universal AC/DC, 1/4 HP, Nameplate RPM 20,000, No. of Speeds 1, 115V AC Voltage, Non-Standard Frame, Usable @ 208V No, Usable @ 200V No, 60 Hz, Motor Service Factor 1, Motor Thermal Protection One-Shot, Ins. Class A, Max. Ambient Temp. 40 Degrees C, Motor Shaft Rotation CCWSE, Motor Enclosure Design Open, Motor Mounting Type Hole, Motor Mounting Position All Angle, Finish Enamel, Shaft Dia. 5/16 in, Shaft Length 7/8 in, Motor Shaft Design Round
Vacuum Motor, Single Phase, Motor Design Universal AC/DC, Nameplate RPM 25,630, No. of Speeds 1, 120V AC Voltage, Full Load Amps 10.1, Motor/Blower Type Thru-Flow, Max. Amps 10.3 A, 60/50 Hz, Motor Thermal Protection None, Ins. Class A, Max. Ambient Temp. 40 Degrees C, Duty Cycle Intermittent, Motor Enclosure Design Open Dripproof, Motor Mounting Type Lug, Motor Mounting Position All Angle, Max. Air Watts 373 W, Vacuum Rating 100.2, CFM @ 2-In. Orifice 120.7 cfm
AC/DC Vacuum Motor, Body Diameter 5.7 Inches, Blower Stages 2, Voltage @ 50/60 Hz 36 Volts, Maximum Current Rating 10.8 Amps, Maximum Air Power 113 Watts, Bearing Ball, Air Flow @ 2 Inches Orifice 70.7 CFM, Vacuum (H2O Sealed) 47.3 Inches, Style D, Overall Height 6 1/2 Inches, Peripheral Discharge, Thermoset Mounting Brackets, Air Sealed Bearing Protection
Vacuum Motor; Single Phase; Motor Design Universal AC/DC; Nameplate RPM 24;467; No. of Speeds 1; 120V AC Voltage; Full Load Amps 9.8; Non-Standard Frame; Motor/Blower Type Bypass; Max. Amps 9.9 A; 60/50 Hz; Motor Thermal Protection None; Ins. Class A; Max. Ambient Temp. 40 Degrees C; Duty Cycle Intermittent; Motor Enclosure Design Open; Motor Mounting Type Lug; Motor Mounting Position All Angle; Max. Air Watts 301 W; Vacuum Rating 92.5; CFM @ 2-In. Orifice 97.4 cfm
Vacuum Motor; Single Phase; Motor Design Universal AC/DC; Nameplate RPM 14;620; No. of Speeds 1; 120V AC Voltage; Full Load Amps 11.0; Motor/Blower Type Bypass; Max. Amps 7.3 A; 60/50 Hz; Motor Thermal Protection None; Ins. Class A; Max. Ambient Temp. 40 Degrees C; Duty Cycle Intermittent; Motor Enclosure Design Open Dripproof; Motor Mounting Type Lug; Motor Mounting Position All Angle; Max. Air Watts 359 W; Vacuum Rating 88.1; CFM @ 2-In. Orifice 126.4 cfm; Mounting Bracket Material Aluminum
Standard Thru Flow Vacuum Motor/Blower; Body Diameter 5.7 Inches; Blower Stages 2; Voltage @ 50/60 Hz 24 Volts; Maximum Current Rating 15.7 Amps; Maximum Air Power 90 Watts; Bearing Ball/Ball; Air Flow @ 2 Inches Orifice 65.4 CFM; Vacuum (H2O Sealed) 47.9 Inches; Thermal Protection No; Style A; Overall Height 5 9/16 Inches
Vacuum Motor; Single Phase; Motor Design Universal AC/DC; Nameplate RPM 23;600; No. of Speeds 1; 120V AC Voltage; Full Load Amps 7.3; Non-Standard Frame; Motor/Blower Type Thru-Flow; Max. Amps 7.5 A; 60 Hz; Motor Thermal Protection Auto; Ins. Class A; Max. Ambient Temp. 40 Degrees C; Duty Cycle Intermittent; Motor Enclosure Design Open Dripproof; Motor Mounting Type Lug; Motor Mounting Position All Angle; Max. Air Watts 257 W; Vacuum Rating 92.4; CFM @ 2-In. Orifice 98 cfm
Vacuum Motor; Single Phase; Motor Design Universal AC/DC; Nameplate RPM 22;540; No. of Speeds 1; 220V AC Voltage; Full Load Amps 3.6; Non-Standard Frame; Motor/Blower Type Thru-Flow; Max. Amps 3.7 A; 60/50 Hz; Motor Thermal Protection None; Ins. Class A; Max. Ambient Temp. 40 Degrees C; Duty Cycle Intermittent; Motor Enclosure Design Open Dripproof; Motor Mounting Type Lug; Motor Mounting Position All Angle; Max. Air Watts 225 W; Vacuum Rating 87.3; CFM @ 2-In. Orifice 95.4 cfm
Vacuum Motor; Single Phase; Motor Design Universal AC/DC; Nameplate RPM 22;150; No. of Speeds 1; 120V AC Voltage; Full Load Amps 12.6; Motor/Blower Type Bypass; Max. Amps 12.6 A; 60/50 Hz; Motor Thermal Protection None; Ins. Class A; Max. Ambient Temp. 40 Degrees C; Duty Cycle Intermittent; Motor Enclosure Design Open Dripproof; Motor Mounting Type Lug; Motor Mounting Position All Angle; Max. Air Watts 438 W; Vacuum Rating 135; CFM @ 2-In. Orifice 94.3 cfm; Mounting Bracket Material Aluminum
Vacuum Motor; Single Phase; Motor Design Universal AC/DC; Nameplate RPM 22;600; No. of Speeds 1; 120V AC Voltage; Full Load Amps 7.9; Motor/Blower Type Bypass; Max. Amps 5.2 A; 60/50 Hz; Motor Thermal Protection None; Ins. Class A; Max. Ambient Temp. 40 Degrees C; Duty Cycle Intermittent; Motor Enclosure Design Open Dripproof; Motor Mounting Type Lug; Motor Mounting Position All Angle; Max. Air Watts 292 W; Vacuum Rating 88.1; CFM @ 2-In. Orifice 96 cfm; Mounting Bracket Material Aluminum
Vacuum Motor; Single Phase; Motor Design Universal AC/DC; Nameplate RPM 24;716; No. of Speeds 1; 120V AC Voltage; Full Load Amps 10.9; Motor/Blower Type Bypass; Max. Amps 7.5 A; 60/50 Hz; Motor Thermal Protection None; Ins. Class A; Max. Ambient Temp. 40 Degrees C; Duty Cycle Intermittent; Motor Enclosure Design Open; Motor Mounting Type Lug; Motor Mounting Position All Angle; Max. Air Watts 386 W; Vacuum Rating 107.8; CFM @ 2-In. Orifice 97.8 cfm; Motor Bearings Ball; Blower Stages 2
Vacuum Motor; Single Phase; Motor Design Universal AC/DC; No. of Speeds 1; 120V AC Voltage; Full Load Amps 7.7; Motor/Blower Type Thru-Flow; Max. Amps 7.7 A; 60/50 Hz; Motor Thermal Protection Auto; Ins. Class A; Max. Ambient Temp. 40 Degrees C; Duty Cycle Intermittent; Motor Enclosure Design Open Dripproof; Motor Mounting Type Lug; Motor Mounting Position All Angle; Max. Air Watts 241 W; Vacuum Rating 90.2; CFM @ 2-In. Orifice 94 cfm; Mounting Bracket Material Metal; Motor Bearings Ball
Vacuum Motor; Single Phase; Motor Design Universal AC/DC; No. of Speeds 1; 220V AC Voltage; Full Load Amps 5.8; Motor/Blower Type Thru-Flow; Max. Amps 5.8 A; 60/50 Hz; Motor Thermal Protection None; Ins. Class A; Max. Ambient Temp. 40 Degrees C; Duty Cycle Intermittent; Motor Enclosure Design Open; Motor Mounting Type Lug; Motor Mounting Position All Angle; Max. Air Watts 291 W; Vacuum Rating 93.7; CFM @ 2-In. Orifice 113 cfm; Mounting Bracket Material Metal; Motor Bearings Ball; Blower Stages 2
Industrial/Commercial Vacuum Motor/Blower; Body Diameter 7.5 Inches; Blower Stages 3; Voltage @ 50/60 Hz 42 Volts; Maximum Current Rating 30.0 Amps; Maximum Air Power 360 Watts; Air Flow @ 2 Inches Orifice 126.0 CFM; Vacuum (H2O Sealed) 87.9 Inches; Overall Height 9 7/16 Inches
AC/DC Vacuum Motor; Body Diameter 5.7 Inches; Blower Stages 2; Voltage @ 50/60 Hz 24 Volts; Maximum Current Rating 14.4 Amps; Maximum Air Power 98 Watts; Bearing Ball; Air Flow @ 2 Inches Orifice 66.4 CFM; Vacuum (H2O Sealed) 43.6 Inches; Style B; Overall Height 6 5/16 Inches; Tangential Discharge; Thermoset Mounting Brackets; Air Sealed Bearing Protection
Replacement Brush Mechanism; For Use With Mfr. No. 115923; Mfr. No. 116432-00; Mfr. No. 116471-13; Mfr. No. 116472-13; Mfr. No. 116474-37; Mfr. No. 116565-13; Mfr. No. 116565-29; Mfr. No. 116566-13; Mfr. No. 116763-13; Mfr. No. 116764-13; Package Quantity 2
Vacuum Motor; Single Phase; Motor Design Universal AC/DC; No. of Speeds 1; 120V AC Voltage; Full Load Amps 13.8; Motor/Blower Type Bypass; Max. Amps 13.8 A; 60 Hz; Motor Thermal Protection Manual; Ins. Class A; Max. Ambient Temp. 40 Degrees C; Duty Cycle Intermittent; Motor Enclosure Design Open; Motor Mounting Type Lug; Motor Mounting Position All Angle; Max. Air Watts 700 W; Vacuum Rating 150; CFM @ 2-In. Orifice 142 cfm; Mounting Bracket Material Aluminum; Motor Bearings Ball
Replacement Motor Brush Set; For Use With 115737; 115750; 115757-P; 116114-00; 116207-00; 116210-50; 116210-85; 116212-00; 116336-00; 116336-01; 116378-00; 116669-50; 116671-50; 116758-13; 116884-49; Mfr. No. 116146-00; Package Quantity 2
Vacuum Motor; Single Phase; Motor Design Universal AC/DC; Nameplate RPM 23;713; No. of Speeds 1; 120V AC Voltage; Full Load Amps 9.0; Non-Standard Frame; Motor/Blower Type Bypass; Max. Amps 9.1 A; 60/50 Hz; Motor Thermal Protection None; Ins. Class A; Max. Ambient Temp. 40 Degrees C; Duty Cycle Intermittent; Motor Enclosure Design Open Dripproof; Motor Mounting Type Lug; Motor Mounting Position All Angle; Max. Air Watts 300 W; Vacuum Rating 91.3; CFM @ 2-In. Orifice 104 cfm
Vacuum Motor; Single Phase; Motor Design Universal AC/DC; No. of Speeds 1; 120V AC Voltage; Full Load Amps 10.5; Motor/Blower Type Bypass; Max. Amps 10.5 A; 60/50 Hz; Motor Thermal Protection None; Ins. Class A; Max. Ambient Temp. 40 Degrees C; Duty Cycle Intermittent; Motor Enclosure Design Open; Motor Mounting Type Lug; Motor Mounting Position All Angle; Max. Air Watts 330 W; Vacuum Rating 165; CFM @ 2-In. Orifice 60 cfm; Mounting Bracket Material Aluminum; Motor Bearings Ball; Blower Stages 4
Vacuum Motor; Single Phase; Motor Design Universal AC/DC; Nameplate RPM 25;312; No. of Speeds 1; 120V AC Voltage; Full Load Amps 12.6; Non-Standard Frame; Motor/Blower Type Bypass; Max. Amps 13.1 A; 60/50 Hz; Motor Thermal Protection None; Ins. Class A; Max. Ambient Temp. 40 Degrees C; Duty Cycle Intermittent; Motor Enclosure Design Open; Motor Mounting Type Lug; Motor Mounting Position All Angle; Max. Air Watts 465 W; Vacuum Rating 136; CFM @ 2-In. Orifice 95.3 cfm