Close
Noble
Free Shipping on orders over $100 - CONUS ONLY
Home
Filters
Apply Filters

NARROW DOWN


COUNTRY_OF_ORIGIN
-

-

Japan

SOUTH KOREA

United States


CONTRACT
-

47QSCCD0007


BRAND
-
NEXTTEQ Detector Tube,For Nitrogen Oxides
Detector Tube, Measurement Range 100 to 2,500 ppm, Gas Detected Nitrogen Oxide, For Use With Mfr. No. NX-1000-100, Mfr. No. NX-1000-130, Mfr. No. NX-1000-150, Mfr. No. NX-1000-200, Mfr. No. NX-1000-230, Mfr. No. NX-1000-250, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Sampling Method With Pump, Shelf Life 2 yr, Application Exhaust Gas Analysis, Chemical Formula NO, Package Quantity 10
NEXTTEQ Detector Tube,For Tetrachloroethylene
Detector Tube, Measurement Range 125 to 1250 ppm/50 to 500 ppm, Gas Detected Tetrachloroethylene, For Use With 20 m Extension Hose, Mfr. No. NX-1000, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Sampling Method With Pump, Shelf Life 1 yr, Application Process Control in Dry Cleaning Industry, Chemical Formula C2Cl4, CAS Number 127-18-4, Package Quantity 10
NEXTTEQ Detector Tube,For Furfuryl alcohol
Detector Tube, Measurement Range 5 to 25 ppm, Gas Detected Furfuryl Alcohol, For Use With Mfr. No. NX-1000-100, Mfr. No. NX-1000-130, Mfr. No. NX-1000-150, Mfr. No. NX-1000-200, Mfr. No. NX-1000-230, Mfr. No. NX-1000-250, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Sampling Method With Pump, Shelf Life 1 yr, Application Industrial Hygiene, Material of Furan Resin, Resin Denaturant, Solvent, Chemical Formula C5H6O2, CAS Number 98-00-0
NEXTTEQ Detector Tube,For Methanol,Glass
Detector Tube, Measurement Range 100 to 1,000 ppmv, Gas Detected Methanol, For Use With Mfr. No. NX-1000-100, Mfr. No. NX-1000-130, Mfr. No. NX-1000-150, Mfr. No. NX-1000-200, Mfr. No. NX-1000-230, Mfr. No. NX-1000-250, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Sampling Method With Pump, Shelf Life 3 yr, Chemical Formula CH3OH, CAS Number 67-56-1, Package Quantity 10
NEXTTEQ Detector Tube,For Phosphine in Acetylene
Detector Tube, Measurement Range 20 to 800 ppm, Gas Detected Phosphine in Acetylene, For Use With Mfr. No. NX-1000-100, Mfr. No. NX-1000-130, Mfr. No. NX-1000-150, Mfr. No. NX-1000-200, Mfr. No. NX-1000-230, Mfr. No. NX-1000-250, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Sampling Method With Pump, Shelf Life 3 yr, Application Impurity Test of Calcium Carbide and Acetylene, Chemical Formula PH3, CAS Number 7803-51-2, Package Quantity 10
NEXTTEQ Detector Tube,For Methyl Iodide
Detector Tube, Measurement Range 0.4 to 8 ppm/1 to 20 ppm/2.5 to 50 ppm, Gas Detected Methyl Iodide, For Use With Mfr. No. NX-1000-100, Mfr. No. NX-1000-130, Mfr. No. NX-1000-150, Mfr. No. NX-1000-200, Mfr. No. NX-1000-230, Mfr. No. NX-1000-250, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Sampling Method With Pump, Shelf Life 1 yr, Application Wood Fumigation, Chemical Formula CH3I, CAS Number 74-88-4, Package Quantity 10
NEXTTEQ Detector Tube,For Isopentyl Alcohol
Detector Tube, Measurement Range 5 to 100 ppm, Gas Detected Isopentyl Alcohol, For Use With Mfr. No. NX-1000-100, Mfr. No. NX-1000-130, Mfr. No. NX-1000-150, Mfr. No. NX-1000-200, Mfr. No. NX-1000-230, Mfr. No. NX-1000-250, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Sampling Method With Pump, Shelf Life 2 yr, Application Industrial Hygiene, Stabilizer for Sodium Thiosulfate (Hypo), Chemical Formula C5H12O, CAS Number 123-51-3, Package Quantity 10
NEXTTEQ Detector Tube,For Oxygen,Glass
Detector Tube, Measurement Range 1.5 to 3 Percent vol/3 to 24 Percent, Gas Detected Oxygen, For Use With Mfr. No. NX-1000-100, Mfr. No. NX-1000-130, Mfr. No. NX-1000-150, Mfr. No. NX-1000-200, Mfr. No. NX-1000-230, Mfr. No. NX-1000-250, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Sampling Method With Pump, Shelf Life 2 yr, Application Oxygen Deficiency in Underground or Closed Vessels, Tunnels and Mines, Chemical Formula O2, CAS Number 7782-44-7
NEXTTEQ Detector Tube,For Ethylene Oxide
Detector Tube, Measurement Range 0.1 to 2 ppm/0.7 to 14 ppm, Gas Detected Ethylene Oxide, For Use With Mfr. No. NX-1000-100, Mfr. No. NX-1000-130, Mfr. No. NX-1000-150, Mfr. No. NX-1000-200, Mfr. No. NX-1000-230, Mfr. No. NX-1000-250, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Sampling Method With Pump, Shelf Life 1 yr, Application Atmospheric Pollution Surveys in Hospitals, Chemical Formula C2H4O, CAS Number 75-21-8, Package Quantity 5
NEXTTEQ Detector Tube,For Hydrogen Sulfide
Detector Tube, Measurement Range 0.05 to 0.6 Percent vol/0.1 to 1.2 Percent vol, Gas Detected Hydrogen Sulfide, For Use With 20 m Extension Hose, Mfr. No. NX-1000, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Sampling Method With Pump, Shelf Life 2 yr, Application Process Control in Sulfur Recovery Plant in Petroleum Refinery, Chemical Formula H2S, CAS Number 7783-06-4, Package Quantity 10
NEXTTEQ Detector Tube,For Sulfide Ion,Glass
Detector Tube, Measurement Range 0.5 to 10 ppm/2 to 1,000 ppm, Gas Detected Sulfide Ion, For Use With Mfr. No. 90005, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Shelf Life 1 yr, Chemical Formula S2, Package Quantity 10
NEXTTEQ Detector Tube;For Ethylene Oxide
Detector Tube; Measurement Range 0.01 to 1.8 Percent vol/1 to 4 Percent vol; Gas Detected Ethylene Oxide; For Use With Mfr. No. NX-1000-100; Mfr. No. NX-1000-130; Mfr. No. NX-1000-150; Mfr. No. NX-1000-200; Mfr. No. NX-1000-230; Mfr. No. NX-1000-250; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Sampling Method With Pump; Shelf Life 3 yr
NEXTTEQ Gas Monitor,Detects Ammonia,1 ppm
Single Gas Ammonia Monitor, Replaceable Battery No, Product Type Single-Gas Detector, Display Screen Type LCD, Includes Probe Yes, Housing Color Black, Gas Detected Ammonia, Communication Protocol Bluetooth, Series NXS, Sub-Brand Nextteq, Battery Size 1/2 AA, Operating Humidity - Maximum 95 Percent, Status Indicator LED, Rechargeable Battery No, Operating Humidity - Minimum 95 Percent, Sensor Type Electrochemical, Temperature Code T4, Alarm Setting High 35 ppm, Low 25 ppm
NEXTTEQ Detector Tube,For Methyl Isothiocyanate
Detector Tube, Measurement Range 200 to 10,000 ppm, Gas Detected Methyl Isothiocyanate, For Use With Mfr. No. NX-1000-100, Mfr. No. NX-1000-130, Mfr. No. NX-1000-150, Mfr. No. NX-1000-200, Mfr. No. NX-1000-230, Mfr. No. NX-1000-250, Tube Material Glass, Break-Off Tip Yes, Calibrated Yes, Product Type Gas Detection Tube, Sampling Method With Pump, Shelf Life 3 yr, Application Wood Fumigation, Chemical Formula CH3NCS, CAS Number 556-61-6, Package Quantity 10
NEXTTEQ Detector Tube;For Sulfur Dioxide
Detector Tube; Measurement Range 1 to 60 ppm; Gas Detected Sulfur Dioxide; For Use With Mfr. No. NX-1000-100; Mfr. No. NX-1000-130; Mfr. No. NX-1000-150; Mfr. No. NX-1000-200; Mfr. No. NX-1000-230; Mfr. No. NX-1000-250; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Sampling Method With Pump; Shelf Life 1 yr; Application Industrial Hygiene; Manufacturing Sulfuric Acid and Nitric Acid; Metal Refinery; Chemical Formula SO2; CAS Number 7446-09-5
NEXTTEQ Detector Tube;For Acrylonitrile
Detector Tube; Measurement Range 0.1 to 3.5 Percent vol; Gas Detected Acrylonitrile; For Use With Mfr. No. NX-1000-100; Mfr. No. NX-1000-130; Mfr. No. NX-1000-150; Mfr. No. NX-1000-200; Mfr. No. NX-1000-230; Mfr. No. NX-1000-250; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Sampling Method With Pump; Shelf Life 2 yr; Application Leakage and Fire Hazard Detection in Synthetic Rubber and Plastics Industry; Chemical Formula C3H3N; CAS Number 107-13-1
NEXTTEQ Detector Tube;For Toluene;Glass
Detector Tube; Measurement Range 10 to 500 ppm; Gas Detected Toluene; For Use With 20 m Extension Hose; Mfr. No. NX-1000; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Sampling Method With Pump; Shelf Life 3 yr; Application Industrial Hygiene; Manufacturing Dye Industry; Rubber and Plastics Industry; Solvent Recovery Control and Fire Hazard Detection in Paints Industry and Painting; Chemical Formula C7H8; CAS Number 108-88-3; Package Quantity 10
NEXTTEQ Detector Tube;For Nitrogen Dioxide
Detector Tube; Measurement Range 20 to 1;000 ppm; Gas Detected Nitrogen Dioxide; For Use With Mfr. No. NX-1000-100; Mfr. No. NX-1000-130; Mfr. No. NX-1000-150; Mfr. No. NX-1000-200; Mfr. No. NX-1000-230; Mfr. No. NX-1000-250; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Sampling Method With Pump; Shelf Life 3 yr; Application Acid Dipping; Arc Welding; Garage; Waste Gas Analysis; Chemical Formula NO2; CAS Number 10102-44-0; Package Quantity 10
NEXTTEQ Detector Tube;For Ethylene;Glass
Detector Tube; Measurement Range 1 to 200 ppm; Gas Detected Ethylene; For Use With Mfr. No. NX-1000-100; Mfr. No. NX-1000-130; Mfr. No. NX-1000-150; Mfr. No. NX-1000-200; Mfr. No. NX-1000-230; Mfr. No. NX-1000-250; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Sampling Method With Pump; Shelf Life 2 yr; Application Used for Fruit Ripening Control; Chemical Formula C2H4; CAS Number 74-85-1; Package Quantity 5
NEXTTEQ Detector Tube;Glass;Tip Break Off
Detector Tube; Measurement Range 10 to 100 ppm; Gas Detected Trichloroethane; For Use With Mfr. No. NX-1000-100; Mfr. No. NX-1000-130; Mfr. No. NX-1000-150; Mfr. No. NX-1000-200; Mfr. No. NX-1000-230; Mfr. No. NX-1000-250; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Sampling Method With Pump; Shelf Life 1 yr; Application Industrial Hygiene; Chemical Formula C2H2Cl4; CAS Number 79-00-5; Package Quantity 5
NEXTTEQ Detector Tube;For Toluene;Glass
Detector Tube; Measurement Range 0.05 to 1 ppm; Gas Detected Toluene; For Use With Mfr. No. NX-1200-100; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Shelf Life 1 yr; Application Indoor Air Pollutants; Chemical Formula C7H8; CAS Number 108-88-3; Package Quantity 10
NEXTTEQ Detector Tube;For Tetrachloroethylene
Detector Tube; Measurement Range 10 to 300 ppm/2.1 to 21 ppm/5 to 150 ppm; Gas Detected Tetrachloroethylene; For Use With 20 m Extension Hose; Mfr. No. NX-1000; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Sampling Method With Pump; Shelf Life 2 yr; Application Metal Decreasing; Painting Industry; Solvent Recovery Control; Chemical Formula C2Cl4; CAS Number 127-18-4; Package Quantity 10
NEXTTEQ Detector Tube;For Ethylene Oxide
Detector Tube; Measurement Range 130 to 2600 ppm/50 to 1;000 ppm; Gas Detected Ethylene Oxide; For Use With Mfr. No. NX-1000-100; Mfr. No. NX-1000-130; Mfr. No. NX-1000-150; Mfr. No. NX-1000-200; Mfr. No. NX-1000-230; Mfr. No. NX-1000-250; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Sampling Method With Pump; Shelf Life 3 yr
NEXTTEQ Single-Gas Detection Tube; PK 10
Single-Gas Detection Tube; Measurement Range 10 to 600 ppm; Gas Detected Sulfur Dioxide; For Use With Dosimeter Tube Holder; Tube Material Glass; Calibrated Yes; Product Type Dosimeter Tube; Sampling Method Without Pump; Sampling Time 48 hr; Chemical Formula SO2; Package Quantity 10
NEXTTEQ Detector Tube;For Ethyl Acetate
Detector Tube; Measurement Range 0.1 to 5 Percent vol; Gas Detected Ethyl Acetate; For Use With Mfr. No. NX-1000-100; Mfr. No. NX-1000-130; Mfr. No. NX-1000-150; Mfr. No. NX-1000-200; Mfr. No. NX-1000-230; Mfr. No. NX-1000-250; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Sampling Method With Pump; Shelf Life 3 yr
NEXTTEQ Gas Monitor;Detects Carbon Monoxide
Single Gas CO Monitor; Replaceable Battery No; Product Type Single-Gas Detector; Display Screen Type LCD; Includes Probe Yes; Housing Color Black; Gas Detected Combustible Gas; Communication Protocol Bluetooth; Series NXS; Sub-Brand Nextteq; Battery Size 1/2 AA; Operating Humidity - Maximum 95 Percent; Status Indicator LED; Rechargeable Battery No; Operating Humidity - Minimum 95 Percent; Sensor Type Electrochemical; Temperature Code T4; Alarm Setting High 200 ppm; Low 35 ppm
NEXTTEQ Detector Tube;For Oxygen;Glass
Detector Tube; Measurement Range 2 to 24 Percent vol; Gas Detected Oxygen; For Use With 20 m Extension Hose; Mfr. No. NX-1000; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Sampling Method With Pump; Shelf Life 2 yr; Application Mines; Oxygen Deficiency in Underground or Closed Vessels; Tunnels; Chemical Formula O2; CAS Number 7782-44-7; Package Quantity 5
NEXTTEQ Detector Tube;For Cyclohexane;Glass
Detector Tube; Measurement Range 0.01 to 0.6 Percent vol; Gas Detected Cyclohexane; For Use With Mfr. No. NX-1000-100; Mfr. No. NX-1000-130; Mfr. No. NX-1000-150; Mfr. No. NX-1000-200; Mfr. No. NX-1000-230; Mfr. No. NX-1000-250; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Sampling Method With Pump; Shelf Life 3 yr; Application Extraction Process of Oils and Fats; Fire Hazard Detection in Paints Industry; Waxes; Chemical Formula C6H12
NEXTTEQ Detector Tube;For Sulfuric Acid
Detector Tube; Measurement Range 0.5 to 5 mg/m3; Gas Detected Sulfuric Acid; For Use With Mfr. No. NX-1000-100; Mfr. No. NX-1000-130; Mfr. No. NX-1000-150; Mfr. No. NX-1000-200; Mfr. No. NX-1000-230; Mfr. No. NX-1000-250; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Sampling Method With Pump; Shelf Life 2 yr; Application Industrial Hygiene; Petrochemical; Chemical Formula H2SO4; CAS Number 7664-93-9; Package Quantity 10
NEXTTEQ Detector Tube;For Chlorine Dioxide
Detector Tube; Measurement Range 1 to 20 ppm; Gas Detected Chlorine Dioxide; For Use With Mfr. No. NX-1000-100; Mfr. No. NX-1000-130; Mfr. No. NX-1000-150; Mfr. No. NX-1000-200; Mfr. No. NX-1000-230; Mfr. No. NX-1000-250; Tube Material Glass; Break-Off Tip Yes; Calibrated Yes; Product Type Gas Detection Tube; Sampling Method With Pump; Shelf Life 2 yr; Application Leakage Detection in Textile and Paper Bleaching Plant; Water Treatment; Chemical Formula ClO2; CAS Number 10049-04-4