Filters
pH Indicator Strips; Test Form Strip; Overall Length 3 1/8 in; Test Type pH Test; Testing Parameter One pH; Overall Width 1/4 in; Parameter Measurements Included 0 to 14 pH; Number of Tests 100; pH Resolution 1.0 pH; Test Detects For pH; Parameter Five Measurements Included Not Applicable; Parameter Four Measurements Included Not Applicable; Parameter Three Measurements Included Not Applicable; Parameter Two Measurements Included Not Applicable; Testing Parameter Four Not Applicable
Qualitative Filter Paper; Diameter 4.25 cm; Material Cellulose; Porosity Medium; Minimum Pore Size 2.5 micron; Maximum Pore Size 2.5 micron; Thickness 0.2 mm; Fluted No; Grade 5; For Use With Liquids; Overall Length Not Applicable; Overall Width Not Applicable; Shape Disc; Package Quantity 100
Test Paper; Test Form Paper; Overall Length Not Applicable; Test Type pH Test; Testing Parameter One pH; Overall Width Not Applicable; Parameter Measurements Included 5 to 8 pH; Number of Tests 10; pH Resolution 0.5 pH; Test Detects For pH; Parameter Five Measurements Included Not Applicable; Parameter Four Measurements Included Not Applicable; Parameter Three Measurements Included Not Applicable; Parameter Two Measurements Included Not Applicable; Testing Parameter Four Not Applicable
Quantitative Filter Paper; Diameter 9 cm; Material High Quality Cotton Linters; Porosity Medium; Minimum Pore Size 8 micron; Maximum Pore Size 8 micron; Thickness 0.21 mm; Fluted No; Grade 40; For Use With Liquids; Overall Length Not Applicable; Overall Width Not Applicable; Shape Disc; Package Quantity 100
Qualitative Filter Paper; Diameter 11 cm; Material Cellulose; Porosity Medium; Minimum Pore Size 10 micron; Maximum Pore Size 10 micron; Thickness 0.145 mm; Fluted No; Grade 93; For Use With Liquids; Overall Length Not Applicable; Overall Width Not Applicable; Shape Disc; Package Quantity 1250
Qualitative Filter Paper; Diameter 18.5 cm; Material Cellulose; Porosity Medium; Minimum Pore Size 8 micron; Maximum Pore Size 8 micron; Thickness 0.19 mm; Fluted No; Grade 2; For Use With Liquids; Overall Length Not Applicable; Overall Width Not Applicable; Standards ASTM E2187-09; Shape Disc; Package Quantity 100
Glass Microfiber Filter; Diameter 15 cm; Grade 934-AH; Pore Size 1.5 um; Material Binderless Glass Microfiber; Product Type Filter; Maximum Operating Temperature - Centigrade 500 Degrees C; For Use With Air Pollution Monitoring; Cell Harvesting; Laboratory Applications; Liquid Scintillation Counting; Removal of Turbidity and Filtration of Bacterial Cultures; Total Suspended Solids in Water; Water Pollution Monitoring; Package Quantity 100
Glass Microfiber Filter; Diameter 25.7 cm; Grade D; Thickness 0.68 mm; Pore Size 2.7 um; Material Binderless Glass Microfiber; Product Type Filter; Maximum Operating Temperature - Centigrade 500 Degrees C; For Use With Air Filtration; Fluid Flow; Gravimetric Analysis of Volatile Materials Where Ignition is Involved; High Particle Loading Capacity; Package Quantity 25
Venting Filters; Diameter - Metric 150 mm; Product Type Filter Capsule; Autoclavable Yes; Maximum Operating Pressure 60 psi; Air Particle Retention 99.97 Percent Retention of all Particles 0.3 micron m
Syringeless Filter; Product Type Syringeless Filter; Maximum Capacity 12 mL; Housing Diameter Not Applicable; Outlet Connection Gender Not Applicable; Outlet Connection Type Not Applicable; Membrane Diameter Not Applicable; Maximum Operating Pressure - English Not Applicable; Maximum Operating Pressure - Metric Not Applicable; Sterile/Non-Sterile Non-Sterile; Inlet Connection Gender Not Applicable; Inlet Connection Type Not Applicable; Pore Size 0.45 um; Filter Material Glass Microfiber
Glass Microfiber Filter; Diameter 3.7 cm; Grade A; Thickness 0.26 mm; Pore Size 1.6 um; Material Borosilicate Glass; Product Type Filter; Maximum Operating Temperature - Centigrade 550 Degrees C; For Use With Algae and Bacteria Cultures; Water Filtration; Foodstuff Analysis; General Purpose Laboratory Filtration; Water Pollution Monitoring of Effluents; Protein Filtration; Radioimmunoassay of Weak B Emitters; Package Quantity 100
Syringe Filter; Product Type Syringe Filter; Maximum Capacity 10 mL; Housing Diameter 13 mm; Outlet Connection Gender Male; Outlet Connection Type Male Luer Slip; Membrane Diameter 13 mm; Maximum Operating Pressure - English 75 psi; Maximum Operating Pressure - Metric 5.2 bar; Sterile/Non-Sterile Non-Sterile; Inlet Connection Gender Female; Inlet Connection Type Female Luer Lock; Pore Size 0.2 um; Filter Material Nylon; Compatible Product Type Female Luer Lock; Housing Material Polypropylene
Glass Microfiber Filter; Diameter 2.1 cm; Grade B; Thickness 0.68 mm; Pore Size 1 um; Material Binderless Glass Microfiber; Product Type Filter; Maximum Operating Temperature - Centigrade 500 Degrees C; For Use With LSC Techniques Where High Loading Capacity is Required; Package Quantity 100
Qualitative Filter Paper; Diameter 7 cm; Material Cellulose; Porosity Medium; Minimum Pore Size 20 micron; Maximum Pore Size 25 micron; Thickness 0.21 mm; Fluted No; Grade 4; For Use With Liquids; Overall Length Not Applicable; Overall Width Not Applicable; Shape Disc; Package Quantity 100
Well Plate; Diameter - Metric Not Applicable; Number of Wells 96; Material Polypropylene; Volume Capacity 2 mL; Product Type Well Plate; Includes Not Applicable; Working Volume per Well 2 mL; Package Quantity 25
Filter Paper; Diameter 24 cm; Material Creped Paper; Porosity Medium; Minimum Pore Size 25 micron; Maximum Pore Size 30 micron; Thickness 0.4 mm; Fluted No; Grade 230; Overall Length Not Applicable; Overall Width Not Applicable; Shape Disc; Package Quantity 50
Qualitative Filter Paper; Diameter 4.25 cm; Material Cellulose; Porosity Medium; Minimum Pore Size 20 micron; Maximum Pore Size 25 micron; Thickness 0.21 mm; Fluted No; Grade 4; For Use With Liquids; Overall Length Not Applicable; Overall Width Not Applicable; Shape Disc; Package Quantity 100
Glass Microfiber Filter; Diameter 3.7 cm; Grade 934-AH; Thickness 0.44 mm; Pore Size 1.5 um; Material Binderless Glass Microfiber; Product Type Filter; Maximum Operating Temperature - Centigrade 500 Degrees C; For Use With Air Pollution Monitoring; Cell Harvesting; Laboratory Applications; Liquid Scintillation Counting; Removal of Turbidity and Filtration of Bacterial Cultures; Total Suspended Solids in Water; Water Pollution Monitoring; Package Quantity 100
Qualitative Filter Paper; Diameter 18.5 cm; Material Cellulose; Porosity Medium; Minimum Pore Size 20 micron; Maximum Pore Size 25 micron; Thickness 0.21 mm; Fluted No; Grade 4; For Use With Liquids; Overall Length Not Applicable; Overall Width Not Applicable; Shape Disc; Package Quantity 100
PolyDisc Filter; Diameter - Metric 50 mm; Outlet Connection Type Tubing; Maximum Inlet Connection - Metric 10 mm; Maximum Outlet Connection - Metric 10 mm; Minimum Inlet Connection - Metric 6 mm; Minimum Outlet Connection - Metric 6 mm; Product Type Inline Filter; Pore Size 0.45 um; Housing Material Polypropylene; Filter Material PTFE Membrane; Inlet Connection Type Tubing; Autoclavable Yes; Inlet Connection 6mm to 10mm Tubing; Filtration Area 16 sq cm; Package Quantity 10
Syringe Filter; Product Type Syringe Filter; Maximum Capacity 10 mL; Housing Diameter 25 mm; Outlet Connection Gender Male; Outlet Connection Type Male Luer Slip; Membrane Diameter 25 mm; Maximum Operating Pressure - English 75 psi; Maximum Operating Pressure - Metric 5.2 bar; Sterile/Non-Sterile Non-Sterile; Inlet Connection Gender Female; Inlet Connection Type Female Luer Lock; Pore Size 0.45 um; Filter Material Polypropylene; Compatible Product Type Female Luer Lock
Qualitative Filter Paper; Diameter 4.25 cm; Material Cellulose; Porosity Medium; Minimum Pore Size 8 micron; Maximum Pore Size 8 micron; Thickness 0.19 mm; Fluted No; Grade 2; For Use With Liquids; Overall Length Not Applicable; Overall Width Not Applicable; Standards ASTM E2187-09; Shape Disc; Package Quantity 100
Extraction Thimble; Body Diameter - Metric 12 mm; Inside Diameter - Metric 10 mm; Overall Height - Metric 50 mm; Wall Thickness 1 mm; Maximum Pore Size Not Applicable; Minimum Pore Size 6 micron; Material Cellulose; For Use With Solid-Liquid Extractiors; Package Quantity 25
Quantitative Filter Paper; Diameter 11 cm; Material High Quality Cotton Linters; Porosity Medium; Minimum Pore Size 16 micron; Maximum Pore Size 16 micron; Thickness 0.22 mm; Fluted No; Grade 43; Overall Length Not Applicable; Overall Width Not Applicable; Shape Disc; Package Quantity 100
Qualitative Filter Paper; Diameter 11 cm; Material Cellulose; Porosity Medium; Minimum Pore Size 20 micron; Maximum Pore Size 25 micron; Thickness 0.21 mm; Fluted No; Grade 4; For Use With Liquids; Overall Length Not Applicable; Overall Width Not Applicable; Shape Disc; Package Quantity 100
Syringe Filter; Product Type Syringe Filter; Maximum Capacity 100 mL; Housing Diameter 25 mm; Outlet Connection Gender Male; Outlet Connection Type Male Luer Slip; Membrane Diameter 25 mm; Maximum Operating Pressure - English 75 psi; Maximum Operating Pressure - Metric 5.2 bar; Sterile/Non-Sterile Non-Sterile; Inlet Connection Gender Female; Inlet Connection Type Female Luer Lock; Pore Size 0.2 um; Filter Material Nylon; Compatible Product Type Female Luer Lock; Housing Material Polypropylene
Quantitative Filter Paper; Diameter 4.25 cm; Material High Quality Cotton Linters; Porosity Medium; Minimum Pore Size 8 micron; Maximum Pore Size 8 micron; Thickness 0.21 mm; Fluted No; Grade 40; For Use With Liquids; Overall Length Not Applicable; Overall Width Not Applicable; Shape Disc; Package Quantity 100
Inline Filter Device; Diameter - Metric 75 mm; Outlet Connection Type Barb; Maximum Inlet Connection - Metric 12.7 mm; Maximum Outlet Connection - Metric 9.52 mm; Minimum Inlet Connection - Metric 9.52 mm; Minimum Outlet Connection - Metric 9.52 mm; Product Type Filter Capsule; Housing Material Polypropylene; Filter Material Glass Microfiber; Inlet Connection Type Barb; Autoclavable Yes; Inlet Connection 1/4 in to 3/8 in Tubing; Air Particle Retention 99 Percent Retention
Syringe Filter; Product Type Syringe Filter; Maximum Capacity 1.4 mL; Housing Diameter 25 mm; Outlet Connection Gender Male; Outlet Connection Type Male Luer Slip; Membrane Diameter 25 mm; Maximum Operating Pressure - English 75 psi; Maximum Operating Pressure - Metric 5.2 bar; Sterile/Non-Sterile Non-Sterile; Inlet Connection Gender Female; Inlet Connection Type Female Luer Lock; Pore Size 0.2 um; Filter Material Nylon; Compatible Product Type Female Luer Lock; Housing Material Polypropylene
Air Filter; Diameter 4.7 cm; Grade EPM 2000; Thickness 0.45 mm; Pore Size 0.3 um; Material Borosilicate Glass; Product Type Air Sampling Filter; Maximum Operating Temperature - Centigrade 500 Degrees C; For Use With Collecting Atmospheric Particulates and Aerosols; EPA TSP Ambient Air Monitoring; Package Quantity 100